Light-induced Effects on Dental Implant Stability

Ultraviolet A and Ultraviolet C Light-induced Effects on Dental Implant Stability

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05467488
Enrollment
66
Registered
2022-07-20
Start date
2017-06-15
Completion date
2018-06-15
Last updated
2023-09-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Missing Teeth

Keywords

dental implants

Brief summary

Until now, limited research has observed the stability of photo functionalized sandblasted acid-etched (SLA) titanium implants. The study includes a sample size of sixty otherwise healthy patients with implant replacement, comparing nonirradiated, irradiated UVA and UVC titanium implants. It was an interventional study with a sample size divided into three groups using simple randomization. Patients with nonirradiated dental implants make the control group A with UVA and UVC dental implants forming groups B and C, respectively. Before functional loading, implant stability was measured on days zero and eight weeks. SPSS 26.0 is used for data analysis. The data for implant stability quotient (ISQ) levels and osseointegration speed index (OSI) were presented as mean ± SD for each group. The effect of UVA and UVC on ISQ2 compared with the baseline ISQ was done by applying multiple simple regression analysis models, whereas the distinction between UVA and UVC was made through a t-test. p ≤ 0.05 was kept statistically significant. The implants irradiated with UVA significantly affected ISQ levels compared to other groups.

Interventions

PROCEDUREphotofunctionalization

UVA and UVC photofunctionalization of dental implants

Sponsors

Prof. Abdul Mueed Zaigham
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* systemically healthy patients with age \> 20 with at least one tooth or more missing

Exclusion criteria

\-

Design outcomes

Primary

MeasureTime frameDescription
ISQ measurement through Ostelltm Mentor deviceeight monthsThe Ostelltm device was initially calibrated using a test peg called the ISQ. A smart peg was used for assessment. The smart peg tightened with 5 Ncm torque is then mounted on implant fixture and the transducer connected perpendicular to the implant . The measuring probe is brought closer to the smart peg without touching it. A beeping sound displays the reading on the monitor. Two successive readings are taken mesiodistally along the jaw and buccolingually perpendicular to the jaw .The RFA measurements taken twice during implant treatment are recorded. All the ISQ values were recorded from one to hundred and a mean was taken.