Skip to content

Comparative Study of Bispectral Index (BIS) Values Obtained From Standard Frontal Position and Alternative Infra-orbital Position During Total Intravenous Anaesthesia (TIVA).

Comparative Study of Bispectral Index (BIS) Values Obtained From Standard Frontal Position and Alternative Infra-orbital Position During Total Intravenous Anaesthesia (TIVA).

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05441644
Enrollment
71
Registered
2022-07-01
Start date
2020-06-30
Completion date
2022-05-30
Last updated
2022-07-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intraoperative Awareness

Brief summary

A study to find agreement of the infraorbtal BIS placement as compared to standard frotal placement

Detailed description

2.1 Study Design This was a prospective, cross-sectional study conducted in single centre, University Hospital. The study protocol was reviewed and granted approval for implementation by the institution Human Research and Ethics Committee (study protocol code: USM/JEPeM/20060307). 2.2 Study Population We recruited 71 patients who were eligible to be enrolled in this study from November 2020 to October 2021. The inclusion criteria were consented adults between the age of 18 and 60 years old, BMI \> 18 and \<30 kg/m2 and ASA physical status I or II underwent general elective surgery under general anaesthesia. We excluded patients who were going for neurosurgery, maxillofacial or facial surgical procedures because the operation site may interfere with the BIS sensors placement. Patients with a history of disabling central nervous or cerebrovascular disease, those on psychiatric medication or central nervous system active drugs, and those who had undergone neurosurgical procedure were also excluded. The patient who had interruption of BIS monitoring of any BIS sensor location at any time frame will be withdrawn from the study. The baseline demographic data of patients were extracted from their medical chart. Demographic data include their age, gender, BMI, ASA physical status and type of surgery. 2.3 Study Method Before induction of anaesthesia, we applied two BIS sensors on each patient at different location (frontal & infra-orbital) and connected two different BIS monitor. Frontal sensors were applied with circle 1 at the centre of forehead, circle 2 2.8cm lateral to circle 1, circle 3 on the corner of the eye and circle 4 in between circle 2 and circle 3 (Picture 1(A)). Infra-orbital sensors were applied with circle 1 across the nose bridge, circle 2 adjacent to circle 1, circle 3 medial from the frontally placed third electrode and circle 4 in between circle 2 and 3 (Picture 1 (B)). Anaesthesia was induced with TCI remifentanil at initial target concentration at 2ng/ml up to 4ng/ml followed with TCI propofol at initial target concentration at 4mcg/ml then titrated upwards to loss of consciousness and intravenous (IV) rocuronium 1.0 mg/kg for muscle relaxant and endotracheal intubation. Anaesthesia was maintained with propofol infusion at target plasma concentration of 3-6mcg/ml and remifentanil 1-8ng/ml; Intra-operative analgesia included IV paracetamol 1g, IV parecoxib 40mg and IV morphine 0.05-0.1mg/kg. At the end of surgery, patients were reversed with IV neostigmine 0.05 mg/kg and atropine 0.02mg/kg. BIS values from each BIS monitor during awake, at loss of consciousness (LOC), after intubation, after the start of surgical incision, every 30 minutes during the intraoperative period (maintenance), after cessation of TCI propofol at which the plasma concentration of propofol is 1.5mcg/ml (emergence) and at extubation were recorded. The frontal BIS was used to guide the depth of anaesthesia, with deep (BIS \< 45), moderate (BIS 45 to 60) and mild hypnosis (BIS \>60). 2.4 Sample Size In order to determine the Kappa agreement for Pearson's correlation between BIS values obtained from frontal versus the infra-orbital sensor position, using t-test, the sample size would be determined with parameter of effect 0.3, an alpha of 0.05 and a power of 80%. The sample size required was 64 patients and with the estimation of 10% drop-out rate, the total number would be 71 patients. In order to determine the relationship between BIS values obtained from frontal versus the infra-orbital sensor position, using linear regression, the sample size would be determined with parameter of effect size 0.15, an alpha of 0.05 and a power of 80%. The sample size required was 55 patients. To satisfy both outcomes, the final sample size for this study would be 71 patients. 2.5 Statistical Analysis Data were recorded and analyzed using SPSS for Window version 22.0. Descriptive statistics were used to summarize the socio-demographic characteristics of subjects. Numerical data were presented as mean (SD) or median (IQR) based on their normality distribution. Categorical data were presented as number and percentage. Correlation of the numerical data obtained from the two different groups were analyzed using Pearson's correlation and scatter plot analysis. Relationship between data obtained from the two groups was determined using simple linear regression.

Interventions

A new placemewnt to monitor intraoperative BIS

Sponsors

Universiti Sains Malaysia
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

two way mixed effect model; aggreement study

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

The inclusion criteria were consented adults between the age of 18 and 60 years old, BMI \> 18 and \<30 kg/m2 and ASA physical status I or II underwent general elective surgery under general anaesthesia. We excluded patients who were going for neurosurgery, maxillofacial or facial surgical procedures because the operation site may interfere with the BIS sensors placement. Patients with a history of disabling central nervous or cerebrovascular disease, those on psychiatric medication or central nervous system active drugs, and those who had undergone neurosurgical procedure were also excluded. The patient who had interruption of BIS monitoring of any BIS sensor location at any time frame will be withdrawn from the study.

Design outcomes

Primary

MeasureTime frameDescription
agreement between frontal BIS vs infraorbital BISintraoperativemeasurements of BIS values on both placement

Secondary

MeasureTime frameDescription
correlation between frontal BIS vs infraorbital BISintraoperativeto find correlation between both measurement

Countries

Malaysia

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026