Skip to content

Coupling Between Clotting Characteristics in Chronic Hemodialysis Patients and the Hemodialyzer Patency

Coupling Between Clotting Characteristics in Chronic Hemodialysis Patients and the Hemodialyzer Patency

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05440201
Acronym
ClotPara
Enrollment
20
Registered
2022-06-30
Start date
2023-04-19
Completion date
2023-05-20
Last updated
2023-05-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bleeding, Coagulation

Brief summary

Twenty stable chronic hemodialysis patients are included and will undergo one, two, three or four midweek test dialysis sessions, depending on a flow chart to follow. All patients are started (week 1) with an anticoagulant Clexane 50IE/kg and are dialyzed with their regular dialyzer and dialysis machine. Depending on the results of measured clotting characteristics and of the dialyzer scanning (i.e. percentage open fibers), it is decided (via the flow chart) whether the patient gets a second session (and so on) with an adapted anticoagulation therapy to ameliorate fiber patency while limiting bleedings.

Detailed description

Twenty stable chronic hemodialysis (HD) patients with a well functioning vascular access will be included. Patients have a hematocrit higher than 30%, and have no known heparin allergy, no severe thrombocytopenia (platelets more than 50.000/µL) or active infection. Patients are not treated with vitamin K antagonists. The study is limited to maximum four test sessions at midweek per patient. Patients are dialysed with their regular dialyzer on their regular dialysis machine. Patients will get a dialysis of 240min with blood flow 300mL/min and dialysate flow 500mL/min. Ultrafiltration is set according to the patient's needs. As usual, patients will get an administration of an anticoagulant in the dialysis circuit to avoid clotting of the extracorporeal circuit. At the start of the first test session, patients receive the anticoagulant Clexane 20-30IE/kg (0.2-0.3mg/kg - rounded to 10). In these 20 patients, clotting characteristics are measured by performing clotting tests, such as thrombin generation test, thrombo-elastogram with Rotem, Platelet Function Analysis (PFA), flow chamber, and the measurement of biochemical markers such as anti-thrombin-III (AT-III), p-selectin, and antiXa. For these measurements, blood is sampled predialysis, 30min after dialysis start, and post dialysis. In order to link these clotting characteristics with dialyzer patency, the dialyzer will be scanned post dialysis with a gold standard micro Computed Tomography (CT) technique. At the end of the dialysis session, a standard rinsing procedure is applied. The dialyzer is then dried for 12-24 hours by continuous positive pressure ventilation in blood and dialysate compartment. During scanning, the dialyzer is mounted vertically on a rotating disc in front of the X-rays source. After image reconstruction, we get images of cross sections of the dialyzer. The non-blocked fibers are counted with an open source computer program used for biological image analysis. By comparing the number of non-blocked fibers with the total number of fibers in a non-used dialyzer, the percentage of fiber blocking can be derived. By comparing the percentage of fiber blocking with the clotting characteristics in the patient, insight can be obtained in the value of the different clotting characteristics. Based on the results of the first midweek session, it is decided (based on a flow chart) whether the patient will also get a second, third and eventual fourth dialysis test session at midweek with an adapted anticoagulation therapy to ameliorate fiber patency while limiting bleedings.

Interventions

OTHERAmount of anticoagulant Clexane

Change (increase/decrease) the amount of Clexane administered at the dialysis start.

Sponsors

University Hospital, Ghent
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SEQUENTIAL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* chronic hemodialysis patients * well functioning vascular access * hematocrit higher than 30%

Exclusion criteria

* known heparin allergy * severe thrombocytopenia (platelets more than 50.000/µL) * active infection * treatment with vitamin K antagonists

Design outcomes

Primary

MeasureTime frameDescription
Dialyzer fiber patency4 midweek sessionsPercentage of open fibers in de dialyzer post dialysis

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026