Skip to content

Clinical Correlation of TKA Alignment and Native Knee Anatomy

Influence of Native Knee Anatomy on Alignment and Outcome After Total Knee Arthroplasty CAT - Clinical Correlation of TKA Alignment and Native Knee Alignment

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05435092
Acronym
CAT
Enrollment
75
Registered
2022-06-28
Start date
2022-04-01
Completion date
2026-10-30
Last updated
2025-01-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Total Knee Arthroplasty (TKA)

Keywords

osteoarthritis, knee protheses, knee replacement, knee alignment, knee pain, 3D-reconstruction Computer Tomography

Brief summary

Total knee arthroplasty (TKA) is still considered the treatment of choice for painful osteoarthritis. In the last decades neutral mechanical knee alignment in the coronal plane has been considered the gold standard. However, the optimal TKA alignment is still debated. Today, component rotation measurements on three-dimensional (3D) reconstructed computed tomography (CT) images are considered the gold standard for assessing native preoperative alignment and TKA component position. In this study pre-and postoperative radiographic measurements, functional scores, and biomechanical parameters of patients with knee osteoarthritis will be assessed with the aim to investigate the relationship between deviations of TKA alignment from native preoperative alignment and clinical, functional and biomechanical alignment.

Detailed description

Total knee arthroplasty (TKA) is still considered the treatment of choice for painful osteoarthritis resulting in pain and functional improvement. Despite the development of novel prosthetic design and improved outcome, about 20% of patients report persisting pain interfering with their daily activities.Total knee prostheses are aligned in the coronal, sagittal and axial planes during implantation. In the last decades, neutral mechanical knee alignment in the coronal plane has been considered the gold standard. The aim of mechanical alignment in TKA is to achieve a femorotibial joint line that is perpendicular to the mechanical axis of the long leg axis hence correcting any varus-valgus deformity via prosthesis placement with the goal of equally distributing the load between the medial and lateral prosthesis component. However, the optimal TKA alignment is still debated. Traditionally, knee alignment and total knee arthroplasty component position have been assessed using radiographs. However, this method has a low accuracy and reliability because of variation in limb rotation, knee extension deficit, patient positioning, or magnification factors. Component rotation measurements on three-dimensional (3D) reconstructed computed tomography (CT) images have replaced former methods and are now considered the gold standard for assessing native preoperative alignment and TKA component position. In this study pre-and postoperative radiographic measurements, functional scores, and biomechanical parameters of patients with knee osteoarthritis will be assessed with the aim to investigate the relationship between deviations of TKA alignment from native preoperative alignment and clinical, functional and biomechanical alignment.

Interventions

RADIATION3D-reconstruction CT

Three dimensional CT (3D CT):Method of surface rendition of anatomy by means of a special computer software to capture 3D bone models used to improve the outcomes of Total Knee Arthroplasty (TKA).

Sponsors

University Hospital, Basel, Switzerland
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum

Inclusion criteria

* Age \> 18 years * Diagnosed osteoarthritis of the knee * Planned primary total knee arthroplasty (cruciate retaining (CR) or posterior stabilizing (PS) designs)

Exclusion criteria

* Inability to provide informed consent * Inability to communicate in German, French, Italian or English * Any previous ipsilateral bony knee procedure prior to TKA * Planned partial knee arthroplasty, semi- or full-constrained knee prosthesis * Patients unlikely to attend clinical follow-up (e.g., when living abroad) * Pregnancy * Female participants of childbearing potential, not using a medically reliable method of contraception, who do not wish to undergo a pregnancy test prior to exposure to i ionizing radiation

Design outcomes

Primary

MeasureTime frameDescription
Deviation of TKA alignment from preoperative native knee alignment in the coronal plane3 monthsPrimary radiographic endpoints to assess alignment deviations in the coronal plane: 1. Whole limb mechanical axis (hip-knee-ankle (HKA) angle, preoperative) 2. Native femoral varus/valgus alignment (preoperative) 3. Native tibial varus/valgus alignment (preoperative) 4. Femoral component varus/valgus alignment 5. Tibial component varus/valgus alignment

Secondary

MeasureTime frameDescription
Evaluation of the Sagittal alignment3 monthsEvaluation of the * Flexion/extension alignment of the femur (preoperative) * Native tibial posterior slope (preoperative) * Flexion/extension alignment of the femoral component * Tibial component posterior slope
Evaluation of the Axial alignment3 monthsEvaluation of the * Native femoral rotation (preoperative) * Native tibial rotation (preoperative) * Rotation of the femoral component * Rotation of the tibial component * Component mismatch rotation
Assessment of Clinical, functional and biomechanical parameters2 yearsFunctional scores: * Oxford Knee Score (OKS) * Knee Osteoarthritis Outcome Score (KOOS) * KSS (Knee Society Score) * NPRS (numeric pain rating scale) * EQ-5D-5L Biomechanical parameters: * Spatiotemporal parameters: walking speed, cadence, stride length, stride duration * Sagittal plane kinematic parameters: difference in dynamic knee flexion range of motion stance, dynamic knee flexion range of motion gait cycle and dynamic hip flexion range of motion stance between affected and unaffected leg * Ambulatory joint mechanics parameters: differences in 3-dimensional joint moments and medial and lateral compartment contact forces, tibia rotation, tibia translation and muscle activation patterns * Muscle strength: Differences in isokinetic muscle strength in knee flexion and knee extension Local adverse events: persistent or worsening pain; infection; any local event

Other

MeasureTime frameDescription
Deviation of preoperative native knee alignment from neutral alignment in the coronal plane3 monthsPrimary radiographic endpoints to assess alignment deviations in the coronal plane: 1. Whole limb mechanical axis (hip-knee-ankle (HKA) angle, preoperative) 2. Native femoral varus/valgus alignment (preoperative) 3. Native tibial varus/valgus alignment (preoperative) 4. Femoral component varus/valgus alignment 5. Tibial component varus/valgus alignment

Countries

Switzerland

Outcome results

None listed