Evaluation of Ablation Lesions Using Cardiovascular Magnetic Resonance Imaging

Evaluation of Ablation Lesions Using Cardiovascular Magnetic Resonance Imaging

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05432024
Acronym
ENABLE-CMR
Enrollment
60
Registered
2022-06-27
Start date
2023-03-08
Completion date
2028-04-01
Last updated
2025-07-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation

Brief summary

Ineffective ablation lesions can cause arrhythmia recurrence after catheter ablation for cardiac arrhythmia. Ablation lesions can be created with various ablation energy modalities. This study uses cardiovascular magnetic resonance imaging to evaluate the ablation lesion characteristics of radiofrequency ablation, ultra-low temperature cryo ablation, and pulsed field ablation. The ablation lesion characteristics of different energy characteristics will be compared. Additionally, arrhythmia recurrence and quality of life will be evaluated for the different energy modalities.

Detailed description

Catheter ablation has become a cornerstone in the treatment of atrial fibrillation (AF). Typically, radiofrequency ablation (RFA) and cryoballoon ablation are used to perform pulmonary vein isolation (PVI). This treatment is effective in the majority of patients, but nevertheless 35% of patients have arrhythmia recurrence at 1-year follow up. These recurrence rates have been attributed to multiple factors, including ineffective ablation lesions, presence of non-pulmonary vein arrhythmia triggers, and disease progression. Ineffective ablation lesions can cause arrhythmia recurrence through electrical reconnection. Electrical reconnection can occur when gaps are present in the ablation line due to non-durable, non-transmural or non-contiguous ablation lesions. Conventionally, ablation lesion assessment is performed using a redo electrophysiology study at three months post-ablation. During a redo electrophysiology study, a catheter is used to measure the local electrical signals to enable identification of sites with electrical reconnection. This method is effective but poses the patient to the procedural risks of these invasive measurements. Cardiovascular magnetic resonance (CMR) imaging may provide an alternative method for the evaluation of ablation lesions. Modern acquisition and post-processing techniques are under development and being used to image the atrial wall. These techniques may effectively visualize the fibrous tissue of ablation lesions, which enables a non-invasive method to characterize the lesions of catheter ablation. To reduce arrhythmia recurrence caused by electrical reconnection, several novel ablation techniques have been developed in the last years. These novel ablation techniques can potentially reduce arrhythmia recurrence by enabling the creation of durable, transmural and contiguous ablation lesions. Novel ablation modalities include ultra-low temperature cryoablation (ULTC) and pulsed field ablation (PFA) that use near-critical nitrogen and pulsed electrical fields to create ablation lesions. The initial clinical outcomes of both ablation modalities are favorable, but little data are available on the ablation lesion characteristics. Additionally, novel techniques were developed to improve the procedural outcomes of RFA. High power, short duration (HPSD) RF energy applications cause more resistive and less conductive tissue heating compared to convention RFA, which results in more durable ablation lesions and less arrhythmia recurrence while safety outcomes are similar. This study aims to use CMR to evaluate the ablation lesion characteristics of HPSD RFA, ULTC and PFA. This novel information can be used to quantitatively compare different ablation modalities. Furthermore, this study could contribute to our knowledge on ablation lesion formation, which may be used to further develop our ablation strategies.

Interventions

DEVICECatheter ablation

An ablation catheter is introduced in the heart. Ablation is performed by applying ablation energy to the target tissue. The aim of ablation is to create an ablation lesion that does not conduct the electrical signals that induce or sustain the cardiac arrhythmia.

Sponsors

R&D Cardiologie
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Adult patients (age ≥18 years old) * Paroxysmal or persistent atrial fibrillation, meeting criteria of the 2020 European Society of Cardiology Guidelines for diagnosis and management of atrial fibrillation * Patients scheduled to undergo catheter ablation for cardiac arrhythmia using one of the following techniques: Radiofrequency ablation (High power, short duration), Ultra-low temperature cryo ablation, or Pulsed field ablation

Exclusion criteria

* Known (or suspected) allergic reaction to gadolinium * Contraindications for MRI (such as claustrophobia, certain implants, devices, high body mass index). * Pregnancy or breastfeeding * Prior intervention in the left atrium (ablation or surgery)

Design outcomes

Primary

MeasureTime frameDescription
Length of gaps in the ablation lesionsAt 3 months follow upCardiovascular magnetic resonance imaging is used to visualize the ablation lesion. If gaps are present in the ablation lesion, the length of the gaps is measured in millimeter.

Secondary

MeasureTime frameDescription
Number of gaps in the ablation lesionAt 3 months follow upCardiovascular magnetic resonance imaging is used to visualize the ablation lesion. The number of gaps in the ablation lesion are counted.
Location of gaps in the ablation lesionAt 3 months follow upCardiovascular magnetic resonance imaging is used to visualize the ablation lesion. If gaps are present in the ablation lesion, the location of the gaps is recorded.
Recurrence of atrial arrhythmiaUntil 1 year of follow upAmbulatory rhythm monitoring will be performed at 3 and 12 months follow up to assess for recurrences of atrial arrhythmia (i.e. atrial fibrillation, atrial flutter, atrial tachycardia). Additionally, planned and symptom-driven electrocardiograms are assessed for atrial arrhythmia.
Atrial arrhythmia burdenBaseline, 3 and 12 months follow upAmbulatory rhythm monitoring will be performed at baseline, 3 and 12 months follow up to assess the atrial arrhythmia (i.e. atrial fibrillation, atrial flutter, atrial tachycardia) burden (proportion of time in atrial arrhythmia).
Atrial fibrillation related quality of lifeBaseline, 3 and 12 months follow upA validated questionnaire (AFEQT) will be used to evaluate the atrial fibrillation related quality of life at baseline, 3 and 12 months follow up.

Countries

Netherlands

Contacts

Primary ContactLucas VA Boersma, MD, PhD
l.boersma@antoniusziekenhuis.nl0883200900
Backup ContactBob GS Abeln, MD
b.abeln@antoniusziekenhuis.nl0883201212

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026