Predicting Outcomes in Hypoglossal Nerve Stimulation Therapy With Stimulated Upper Airway Mechanics

Assessing Stimulated Upper Airway Mechanics to Predict Outcomes in Hypoglossal Nerve

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05429983
Enrollment
60
Registered
2022-06-24
Start date
2022-11-29
Completion date
2028-11-29
Last updated
2025-12-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sleep Apnea, Obstructive

Brief summary

Obstructive sleep apnea (OSA) is a highly prevalent disease resulting from dynamic upper airway collapse during sleep. Continuous positive airway pressure (CPAP) is highly efficacious but high rates of non-adherence to CPAP leaves large number of OSA patients at risk for cardiometabolic sequelae. Inspire™ is an FDA-approved hypoglossal nerve stimulation device (HGNS) used in select patients with OSA who are intolerant of CPAP. The device consists of an implanted impulse generator with a stimulating cuff lead around the distal hypoglossal nerve. Despite these stringent selection criteria, up to one-third of patients implanted have inadequate responses to HGNS and remain at risk for complications from untreated OSA. The current proposal builds on routine clinical care to characterize upper airway biomechanics and determine predictors of clinical responses to HGNS therapy. Drug induced sleep endoscopy (DISE) is a prerequisite for HGNS treatment and represents an ideal opportunity to rapidly characterize upper airway dynamics under controlled, standardized conditions. The amount of nasal pressure required to relieve airway obstruction (minimal therapeutic pressure) is a significant predictor of successful treatment of OSA with HGNS. As a result, CPAP titration (measuring pharyngeal collapse patterns at varying nasal pressures) has become an integral part of DISE to select parties for HGNS at multiple institutions. Nevertheless, changes in upper airway collapsibility in response HGNS may differ significantly between patients. This stud will examine if changes in upper airway patency with direct genioglossus muscle stimulation at the time of DISE predicts successful treatment with HGNS as defined by a 50% reduction on apnea-hypopnea index (AHI) and an on-treatment AHI \<20.

Interventions

None listed

Sponsors

American Academy of Sleep Medicine
CollaboratorOTHER
Johns Hopkins University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum

Inclusion criteria

* Male and female participants with moderate or severe sleep apnea (defined by \> 15 apneas and hypopneas per hour of sleep), who are undergoing DISE as part of routine evaluation for Inspire hypoglossal nerve stimulation therapy or for ineffective HGNS therapy.

Exclusion criteria

* Significant cardiac disease, unstable or recent cardiac events * Active pulmonary, liver or renal disease * Uncontrolled hypertension (BP\>160/100) * Neuromuscular disease * Major psychiatric disease * Pregnancy * Anticoagulation therapy (e.g. Coumadin, Dabigatran)

Design outcomes

Primary

MeasureTime frameDescription
Tidal airflow with direct genioglossus stimulationat the time of drug-induced sleep endoscopy, up to 1 hourTidal airflow (mL) with direct stimulation of the genioglossus muscle will be measured at the time of drug-induced sleep endoscopy.
HGNS therapy success as assessed by the apnea hypopnea indexat 1 year post HGNS implantationSuccessful treatment with HGNS, as defined by a 50% reduction in apnea hypopnea index (AHI) and an on-therapy AHI of \<15 (the same criteria as in major trials of non-CPAP OSA treatment).

Secondary

MeasureTime frameDescription
Therapeutic CPAP pressure with direct genioglossus stimulationAt the time of drug-induced sleep endoscopy, up to 1 hourTherapeutic CPAP pressure (cmH20) with direct stimulation of the genioglossus muscle will be measured at the time of drug-induced sleep endoscopy.
Airway critical closing pressure with direct genioglossus stimulationAt the time of drug-induced sleep endoscopy, up to 1 hourAirway critical closing pressure (cmH20) with direct stimulation of the genioglossus muscle will be measured at the time of drug-induced sleep endoscopy.