Zeiss® IOLMaster 700 Corneal Topography Module Comparison With Schwind's Sirius Corneal Topography®

Zeiss® IOLMaster 700 Corneal Topography Module Comparison With Schwind's Sirius Corneal Topography®

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05414773
Acronym
VIMECT
Enrollment
100
Registered
2022-06-10
Start date
2022-09-01
Completion date
2024-01-30
Last updated
2022-08-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Brief summary

In order to determine the intraocular lens to be implanted during cataract surgery, keratometry and axial length must be measured in preoperative. The axial length is obtained by ocular ultrasound mode B. Keratometry is obtained by means of an automatic refractometer or corneal topography. Currently, ultrasound scanners are being developed with a topography module to combine axial length and keratometry measurement. The investigators want to evaluate the corneal topography module of the Zeiss® IOL Master 700 biometer.

Interventions

OTHERmeasurement of axial length and keratometry by sonographers with a topographic module

measurement of axial length and keratometry by sonographers with a topographic module

Sponsors

Edouard KOCH
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Men and Women Requiring CHV Cataract Surgery * Aged 18 or over * Insured under a social security scheme * Having been informed of the clinical study and having given oral express consent

Exclusion criteria

* Person unable to express consent * Patient with a history of corneal dystrophy, corneal refractive surgery or keratoconus. * History of chronic corneal disease

Design outcomes

Primary

MeasureTime frameDescription
keratometry measurementsday 1to show that the keratometry measurements obtained using the topography module integrated in the IOL Master 700 are consistent with those obtained by a standard topography in patients operated for cataract surgery. The measures will be: K1 (steepest corneal meridian), K2 (flattest corneal meridian), Kmax (central corneal keratometry), the unit of measurement is the diopter.

Outcome results

None listed