Skip to content

MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval Study

MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval Study

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05409989
Enrollment
154
Registered
2022-06-08
Start date
2022-09-20
Completion date
2030-05-01
Last updated
2026-03-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intracranial Aneurysm

Brief summary

The objective of this study is to generate contemporaneous clinical data to facilitate a reasonable comparison of the performance of the FRED™ X™ device with the performance of the FRED™ device. The data generated from this study will be compared to the safety and effectiveness of the FRED™ device by meeting the same performance goals (PGs) established for the FRED™ pivotal study.

Interventions

DEVICEFRED™ X™

The FRED™ X™ System is indicated for use in the internal carotid artery from the petrous segment to the terminus for the endovascular treatment.

Sponsors

Microvention-Terumo, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
22 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

Subjects for this study must meet ALL the following criteria: 1. Subject has single target aneurysm in the internal carotid artery from petrous segment to the terminus of the internal carotid artery. 2. The parent artery diameter must be 2.0 - 5.0 mm distal and/or proximal to the target intracranial aneurysm. 3. Negative pregnancy test (serum or urine) in a female subject who has had menses in the last 18 months. 4. Subject commits to return to the investigational site for the 30- day, 6-month, 12-month, 2-year, 3-year, and 5-year follow-up evaluations. 5. The subject or his/her authorized representative must sign the IRB-approved written informed consent form prior to the start of any study procedures. 6. The subject has a modified Rankin Scale (mRS) ≤ 2. 7. The subject has a wide-necked ( ≥4mm or dome-to-neck ratio \<2) saccular or fusiform aneurysm.

Exclusion criteria

Subjects shall be excluded from the study if ANY of the following conditions exist: 1. Subject who suffers from a subarachnoid hemorrhage in the last 60 days. 2. Subject who suffers from intracranial hemorrhage in the last 30 days. 3. Subject who presents with an intracranial mass or currently undergoing radiation therapy for carcinoma of the head or neck region. 4. Subject with symptomatic extracranial or intracranial stenosis of the parent artery (\>50%) proximal to the target aneurysm. 5. Subject with an irreversible bleeding disorder, a platelet count \< 100 x 103 cells/mm3 or known platelet dysfunction or a contraindication to or inability to tolerate anticoagulants/antiplatelet agents or thrombolytic drugs. 6. Subject with history of major bleeding disorder (based on coagulation profile and platelet count) and/or subject presents with signs of active bleeding. 7. Subject with known hypersensitivity to any component of the treatment device that cannot be medically controlled. 8. Subject with documented contrast allergy, or other condition that prohibits imaging. 9. Evidence of active bacterial infection at the time of treatment. 10. Presence of any of the following unequivocal cardiac sources of embolism: chronic or paroxysmal atrial fibrillation, mitral stenosis, mechanical valve, endocarditis, intracardiac clot or vegetation, myocardial infarction within 3 months, dilated cardiomyopathy, left atrial spontaneous echo contrast, ejection fraction less than 30%. 11. Subject with a pre-existing stent in place at the target aneurysm. 12. Subject who is unable to complete the required follow-ups. 13. Subject who is pregnant, breastfeeding, or of childbearing potential and unwilling to prevent pregnancy during their participation in the study. 14. Subject has a serious or life-threatening comorbidity that could confound study results and/or prevent completion of 5-year followup. 15. Subject is enrolled in another device or drug study in which participation could confound study results. 16. Subject has absent femoral pulses or other condition preventing femoral access, or is planned to be treated using a radial access approach.

Design outcomes

Primary

MeasureTime frameDescription
Primary Safety Endpoint Part 1: Proportion of subjects that experience either Death or major stroke within 30 days post-procedure.30-daysMajor stroke is defined as a new neurological event that persists for \>24 hours and results in a ≥4-point increase in the NIHSS score compared to baseline or compared to any subsequent lower score.
Primary Safety Endpoint Part 2: Proportion of subjects that experience neurological death or major ipsilateral stroke within 12 months post-procedure.12 monthsA major ipsilateral stroke is defined as that occurring within the vascular distribution of the stented artery. Neurological death is defined as a death which has been adjudicated by an independent clinical events committee to have directly resulted from a neurologic cause.
Primary Effectiveness Endpoint: The percent of subjects with (1) complete (100%) occlusion of the target aneurysm and ≤50% stenosis of the parent artery at the target IA, and (2) in whom an alternative treatment of the target IA had not been performed.12 months(1) Complete (100%) occlusion of the target aneurysm is assessed utilizing the Raymond-Roy Scale (Raymond Roy Class 1) and ≤50% stenosis of the parent artery at the target IA), and in whom an alternative treatment of the target IA had not been performed. The study will utilize independent Core Laboratory to adjudicate all angiographic outcomes, including aneurysm occlusion status and parent artery stenosis. (2) Alternative treatment is defined as re-treatment of the target aneurysm with an alternative treatment modality including open repair, endovascular placement of an additional stent or treatment of in-stent stenosis.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 25, 2026