Photoplethysmographic Measurements of Pulse Wave Velocity (PWV) and Blood Pressure (BP)

Photoplethysmographic Measurements of Pulse Wave Velocity (PWV) and Blood Pressure (BP) MEPPAVOP

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05393401
Acronym
MEPPAVOP
Enrollment
27
Registered
2022-05-26
Start date
2022-10-25
Completion date
2026-06-30
Last updated
2025-09-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy Volunteers

Keywords

Photoplethysmography, Pulse Wave Velocity (PWV), Blood Pressure (BP)

Brief summary

Theoretically, there is a correlation between the PWV and the value of the BP, mediated by the distensibility of the segment of artery where the measurements take place. The hypothesis is therefore that the measurement of the PWV through a multisite medical device for detecting the pulse wave by photoplethysmography makes it possible to deduce the value of the BP.

Detailed description

The aim is to test on healthy volunteers a prototype of a non-invasive, non-CE marked medical device (VOP1k ) for the continuous monitoring of pulse wave velocity (PWV) and to study the relationship between this value and the blood pressure (BP). Indeed, the monitoring of hemodynamic parameters constitutes an essential element of the basal monitoring of patients. Among these parameters, the most used and the most routine is the measurement of BP. This measurement makes it possible in particular to detect the presence or absence of arterial hypertension (HTA), which is a major cause of premature mortality, of high prevalence within the population, involving high medical costs. Contrary to what one might think, the practice of measuring BP is not completely satisfactory, each of the techniques used having characteristics likely to lead to errors of judgment. Oscillometric and auscultatory techniques give discontinuous measurements, expose to the white coat effect when they are performed by a caregiver. Arterial occlusion by external back pressure, which is the basis of these measurement techniques, causes erroneous results and discomfort during repetitive measurements. The use of commercial semi-automatic BP monitors is fraught with validation problems. The necessary confirmation of the diagnosis of hypertension, which is based on ambulatory measurements for 24 hours using these devices, is therefore questionable. The diagnosis of the importance of arterial damage at the base of hypertension could be carried by measurements of the PWV which reflects the stiffness of the arteries. However, this diagnostic means is not currently based on a technology that can be used routinely. Means of measuring BP and arterial stiffness by invasive techniques, which are themselves subject to the risk of poor signal transmission, cannot be used outside the hospital, due to the associated risks. Non-invasive continuous measurement by the volume clamp technique, although devoid of the risks of arterial catheterization, is not available outside specialized hospital departments, and also has the disadvantage of relying on the use of external counter pressure.The technique of measurement by (photoplethysmography (PPG)), i.e. the use of an optical sensor, placed in a non-invasive way on the path of a shallow artery, makes it possible to detect the passage of the pulse wave . The combined use of several sensors located at a distance from each other on the path of the same artery, thus makes it possible to determine the velocity of the pulse wave. This technique can potentially measure over short distances, which limits the sources of error, and allows continuous measurement without discomfort. Moreover, it is compatible with low-cost integration. Indeed, acquisition technologies based on microelectronics are widely developed and mature since their massive use in smartphones. The measurement of PWV makes it possible to quantify arterial stiffness, which is a direct risk factor for morbidity and mortality associated with cardiovascular pathologies. The additional interest of this measurement, in addition to the fact of its non-invasiveness, comes from the fact that there is a correlation between the PWV and the BP, and therefore that the measurement of the PWV can make it possible to obtain a measurement of the BP. It should be noted that one aspect of the aspects of blood pressure measurement consists of being able to measure the central blood pressure, that is to say that which reigns in the aorta. However, most of the measurement techniques used routinely only measure the peripheral arterial pressure, which makes it necessary to use transfer functions to know the central pressure, or to ignore the differences in central pressure/peripheral pressure behavior. The technology proposed for the measurement makes it possible to consider overcoming this problem by placing, in one of the versions, a sensor at the carotid level, which is the arterial segment that best reflects the central pressure, unlike the humeral, femoral or radial segments.

Interventions

DEVICEVOP1k

Photoplethysmographic records

Sponsors

Commissariat A L'energie Atomique
CollaboratorOTHER_GOV
University Hospital, Grenoble
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Intervention model description

The Primary Purpose of this clinical trial is to test a prototype device for feasibility and not health outcomes. This study is conducted to confirm the design and operating specifications of a device before beginning a full clinical trial. Primary Purpose is therefore Device Feasibility

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Healthy healthy volunteer subject, * Aged 18 or over, * Having expressed their consent to the research, * Affiliated to a social security scheme, * Registered in the national file of people who lend themselves to biomedical research

Exclusion criteria

* People referred to in Articles L1121-5 to L1121-8 of the Public Health Code (corresponds to all protected persons: pregnant, parturient or breastfeeding women, persons deprived of liberty by judicial or administrative decision, persons subject of psychiatric care, minor, and person subject to a legal protection measure: guardianship, curatorship or safeguard of justice) * Any history or presence of chronic illness * Presence of Wolf Parkinson White ECG changes * Subject with orthostatic hypotension * People with an active implant (e.g. pacemaker) * Known allergy or intolerance to silicone * Orthostatic hypotension * Cutaneous excoriations preventing the placement of sensors on the arms * Patient with an active implant * Subject cannot be contacted in case of emergency * Taking treatment that may impact the recorded physiological measurements * Subject in period of exclusion from another clinical investigation * Subject who would receive more than 4500 euros in compensation due to his participation in other biomedical research in the 12 months preceding this study

Design outcomes

Primary

MeasureTime frameDescription
Collect and process the pulse wave signal by the multi-site photoplethysmographic method in order to assess the feasibility and reliability of PWV measurement by this technique in a healthy adult population.4 hoursMeasurement of the degree of correlation between the PWV estimated from the device under study and the PWV measured by the Complior® reference device.

Secondary

MeasureTime frameDescription
Determination of the most adequate distance between the sensors for measuring PWV4 hoursMeasurement of the standard PWV deviation measured by the Clearsight device, PWV estimated by the multi-site medical device VOP1k
Study of the relationship between the PWV measured with the device and BP measurement obtained with the gold standard (discrete auscultatory measurements and continuous Clearsight measurements)4 hoursMeasurement of the difference between calculated BP and measured brachial BP to check that it does not exceed 5 to 8 mm Hg
Determination of the most adequate algorithm to obtain BP values from PWV4 hoursCalculation of the algorithm to minimize the difference between calculated BP and measured BP
Check that the signal processing makes it possible to adapt to physiological variations in BP in the same individual4 hoursCalculation of the algorithm to minimize the difference between calculated BP and measured BP obtained during PA modifications caused by the different experimental conditions
Check that the signal processing to obtain the BP can be adapted to different individuals4 hoursCalculation of the algorithm to minimize the difference between calculated BP and measured BP