Skip to content

3D Assessment of RV Function in Patients Undergoing LVAD Implantation

Three-Dimensional Assessment of Right Ventricular Function in Patients Undergoing Left Ventricular Assist Device Implantation

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05376254
Enrollment
200
Registered
2022-05-17
Start date
2022-03-22
Completion date
2027-01-19
Last updated
2026-05-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Keywords

Right Ventricular Function, Left Ventricular Assist Device, 3D transesophageal echocardiography

Brief summary

This goal of this study is to analyze images of the right ventricle taken via 3D transesophageal echocardiography (TEE) during left ventricular assist device (LVAD) implantation.

Detailed description

There are two chambers in the heart known as ventricles which are responsible for pumping blood to both the lungs and the rest of the body. The right ventricle pumps blood to the lungs for oxygenation. The left ventricle then delivers this oxygenated blood to the organs in the body. When the left ventricle is damaged enough that it is not able to effectively pump blood then it may be necessary to assist it with a mechanical pump. This pump is called left ventricular assist device (LVAD). Left ventricular assist devices (LVADs) improve quality of life and survival in patients with end stage heart failure. However, right ventricular (RV) failure is common in 20-50% of LVAD recipients and is associated with perioperative complications. Traditional two-dimensional ultrasound views of the right ventricle may not accurately depict how well or poorly the right ventricle is working. Three-dimensional (3D) images can overcome the limitations of two-dimensional images and are becoming more commonplace. This goal of this study is to analyze images of the right ventricle taken via 3D transesophageal echocardiography (TEE) during the LVAD implantation to help predict which patients are at higher risk of right ventricular failure within 14 days of the procedure.

Interventions

None listed

Sponsors

University of Alberta
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
16 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Patients will be eligible to be included in the study if they receive either a left-sided: 1. HeartMate III (Thoratec, Pleasanton, CA) 2. HeartWare HVAD (HeartWare, Oakville CA) 3. Levitronix CentriMag (Levitronix LLC, Waltham, MA) LVAD.

Exclusion criteria

* Patients will be excluded if:: 1. hemodynamic data needed to calculate PAPi or comprehensive echocardiographic images are missing 2. additional procedures affecting cardiac geometry and/or hemodynamic measurements, such as tricuspid, mitral, and/or aortic valve repair/replacement, were performed at the time of LVAD implantation 3. sternal closure at the end of the procedure is not possible 4. RV mechanical support was introduced concurrently with LVAD implantation 5. inadequate image quality required to obtain a 3D protocol 6. known contraindication to TEE 7. unexpected inability to advance probe into the mid-esophagus

Design outcomes

Primary

MeasureTime frameDescription
Left ventricular strain24 hoursPrognostic indicator of hypertensive heart failure
Right ventricular fractional area of change24 hoursPercentage change in the RV chamber area between end-diastole to end-systole
Right ventricular free wall strain24 hoursPrognostic indicator of pulmonary arterial hypertension
Right ventricular end diastolic volume24 hoursAmount of blood in the heart's right ventricle just before the heart contracts
Light ventricular end diastolic volume24 hoursAmount of blood in the heart's left ventricle just before the heart contracts
Right ventricular end systolic volume24 hoursAmount of blood in the heart's right ventricle just after the heart contracts
Left ventricular end systolic volume24 hoursAmount of blood in the heart's left ventricle just after the heart contracts
Right ventricular ejection fraction24 hoursAmount of blood being pumped out of the right ventricle each time it contracts.
Left ventricular ejection fraction24 hoursAmount of blood being pumped out of the left ventricle each time it contracts.
Tricuspid annular plane systolic excursion24 hoursParameter of global right ventricular function

Secondary

MeasureTime frameDescription
Age1 dayDemographic measure
Gender1 dayDemographic measure
Body Surface Area1 dayDemographic measure
Central venous pressure14 daysPressure in the thoracic vena cava near the right atrium
Pulmonary artery pulsatility index14 daysHemodynamic index
Need for right ventricular mechanical support14 daysCirculatory support
Need for pulmonary vasodilators14 daysSupportive medication
Need for vasopressors14 daysSupportive medications
Aspartate aminotransferase14 daysLab test (\> or qual to 80 IU/L)
Bilirubin14 daysLab test (\> 2.0 mg/dL)
Creatinine14 daysLab test (\> or equal to 2.3 mg/dL)

Countries

Canada

Contacts

CONTACTSurita Sidhu, MD
surita@ualberta.ca780-407-8861
PRINCIPAL_INVESTIGATORSurita Sidhu, MD

University of Alberta

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 30, 2026