Bronchial Asthma
Conditions
Keywords
body Posture, dynamic Balance, Biodex Balance System, DIERS FORMETRIC 4D posture analysis
Brief summary
The purpose of the study is to assess the relationship between body posture and dynamic balance in adults with childhood-onset asthma and compare them to a non-asthmatic control group matched for gender, age, weight, and height.
Detailed description
Participants will sign a consent form and provide personal information such as gender, age, weight, and height for calculating BMI, pulmonary function test, and respiratory muscle strength test, as well as their asthmatic/clinical history. After collecting demographic information and obtaining consent from participants, they will be asked to remove their T-shirts and stand in the usual relaxed standing position facing the opposite side of the machine's window. When the machine is properly positioned, it will take photographs. which will then be converted into three-dimensional images on the computer for further analysis. When the participant is fully dressed and ready, the second test will be performed using the Biodex balance machine. The parameters and testing mode to begin the dynamic balance test will be entered into the machine, and the procedure will begin. The participants will be thanked for their participation and contribution to our study
Interventions
3D/4D spine and posture analysis DIERS FORMETRIC 4D for postural analysis assessment ,The Biodex Balance System SD- for balance assessment
Sponsors
Study design
Eligibility
Inclusion criteria
* For the healthy subjects referred by a consultant pulmonologist/physician * age- and gender-matched volunteers were recruited from the community
Exclusion criteria
* Other health issues, such as cardiorespiratory issues, neurological deficits * musculoskeletal problems and peripheral vascular diseases& pregnancy may affect test performance
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| body posture assessment using DIERS FORMETRIC 4D, | baseline | From a single image, the instrument will generate 40 named spine shape parameters, like( lateral deviation (mm), trunk imbalance (mm), shoulder tilt (mm) ) |
| postural balance assessment by biodex balance system machine | baseline | Double Leg Eyes Open (DLEO) Degree (angle), Double Leg Eyes Closed (DLEC) Degree (angle), Single Leg Eyes Open (SLEO) Degree (angle), single Leg Eyes closed (SLEC) Degree (angle), Overall Balance/stability Index (OBI/OSI )Degree (angle), ANT/POST Balance Index (APBI )Degree (angle), MED/LAT Balance Index (MLBI)Degree (angle), |
Countries
United Arab Emirates