Skip to content

Mini Bolus for Fluid Challenge Responsiveness in the Emergency Department

Mini Bolus for Fluid Challenge Responsiveness in the Emergency Department

Status
Recruiting
Phases
Early Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05369559
Acronym
MIBORED
Enrollment
1000
Registered
2022-05-11
Start date
2022-03-03
Completion date
2025-05-22
Last updated
2024-07-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fluid Therapy

Brief summary

Intravascular volume expansion is a common intervention in critically ill patients with acute circulatory failure.we test the hypothesis that a mini-bolus fluid challenge, of either 50 ml , can predict fluid responsiveness in spontaneously breathing patients with hemodynamic instability.

Detailed description

Background: Intravascular volume expansion is a common intervention in critically ill patients with acute circulatory failure. Nevertheless, approximately 50% of critically ill patients will not benefit from an intravascular volume expansion, since they are in the horizontal portion of the Frank-Starling curve. Thus, an accurate assessment of fluid responsiveness prior to volume expansion is mandatory to avoid fluid overload, which has been associated with increased morbidity and mortality in critically ill patients. Fluid challenge, which consists of administering fluid to assess volume responsiveness, is widely performed. However, repeated fluid challenges, several times a day, can be harmful Indeed, if cardiopulmonary function cannot compensate for the increase in preload, fluid loading can compromise micro-vascular perfusion and oxygen delivery or aggravate peripheral and pulmonary oedema. For many years, spontaneous breathing was considered a major limitation to assess fluid responsiveness in critically ill patients . In this study, the investigator test the hypothesis that a mini-bolus fluid challenge of 50 ml can predict fluid responsiveness in spontaneously breathing patients with hemodynamic instability. Passive leg raising technique: Initially, the patient is placed semi-recumbent with the head of the bed at 45°. After recording baseline measurement, the head of the bed is lowered and the legs are elevated to 45° for 2 minutes. Fluid challenge responsiveness: Fluid responsiveness is defined as an increase in the cardiac output measured using FloTrac-Vigileo monitor (∆CO-PLR \> 10%) after the PLR, separating the studied population into responders and non-responders. Measurements: Patients characteristics, including age and sex, are recorded at admission. The aetiology of acute circulatory failure, the inotropic and/or vasopressor support (epinephrine, norepinephrine and dobutamine) and the APACHE II score are recorded. The following hemodynamic variables are recorded: heart rate (beats per minute), systolic blood pressure (mmHg), diastolic blood pressure (mmHg), and mean arterial blood pressure (mmHg). These variables are collected at baseline (T0), immediately before mini-bolus infusion (T50b, T50a), and immediately before the PLR manoeuvre (TPLRb and TPLRa). Cardiac output (CO) and stroke volume (SV) are measured using both an EsCCO monitor (COescco and SVescco) and a FloTrac transducer connected to a Vigileo monitor (COflotrac and SVflotrac). CO and SV are measured at baseline, before and after each mini-bolus infusion, and before and after passive leg raising. They are recorded at the moment when they plateau. The hemodynamic variables cited above are also recorded at that time. Changes -induced by the mini-boluses and by the PLR- in all parameters were measured; these were referred to as ∆\[parameter\]50 and ∆\[parameter\]PLR. If patients were treated with norepinephrine, the dose remained unchanged from before volume expansion until all hemodynamic measurements were complete.

Interventions

COMBINATION_PRODUCTMini bolus 50

receiving a mini-bolus A:50 ml of crystalloid solution, regularly infused over 30 seconds

DIAGNOSTIC_TESTpassive leg rising test

Passive leg raising technique: Initially, the patient is placed semi-recumbent with the head of the bed at 45°. After recording baseline measurement, the head of the bed is lowered and the legs are elevated to 45° for 2 minutes

Sponsors

University of Monastir
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

The fluid challenge is given intravenously via a specific venous line. Patients are assigned in a random chronological order to: * receive a mini-bolus :50 ml of crystalloid solution, regularly infused over 30 seconds * and passive leg raising. Passive leg raising technique: Initially, the patient is placed semi-recumbent with the head of the bed at 45°. After recording baseline measurement, the head of the bed is lowered and the legs are elevated to 45° for 2 minutes.

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Patients with spontaneous breathing * Patients in whom a fluid challenge is indicated because they present acute circulatory failure (which is defined as systolic blood pressure less than 90 mmHg or the need for vasopressors (norepinephrine more than 0.1 µg/kg/min) to maintain a systolic blood pressure more than 90 mmHg (14), and at least one sign of inadequate tissue perfusion: * urine output of below 0.5ml/kg per hour over 1 hour * tachycardia (heart rate of greater than 100 beats per minute) * mottled skin. * lactate \> 2 mmol/l

Exclusion criteria

* Cardiac arrest * Acute respiratory distress syndrome * Coma Glasgow Scale \< 14 * Age of less than 18 years * Moribund patients * Pregnant patients * impossibility to perform passive leg raising (PLR) (trauma patients, lower extremity amputees, and prone patients) * Patients with cardiac arrhythmias * Patients with cardiogenic pulmonary oedema

Design outcomes

Primary

MeasureTime frameDescription
Measurement of the cardiac flow with the Estimate Continuous CO escco and SVescco (EsCCO) to predict the fluid responsiveness .at 3 minutes following fluid load in the day of admissionPredicting fluid responsiveness in spontaneously breathing patients with hemodynamic instability.

Countries

Tunisia

Contacts

Primary ContactSemir Nouira, Prof
semir.nouira.urg@gmail.com+21673106046
Backup ContactKhaoula Bel Haj Ali, MD
belhajalikhaoula@yahoo.fr99792724

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026