Skip to content

Left Bundle Branch Area Pacing Using Conventional Stylet-driven Pacemaker Leads for Cardiac Resynchronization Therapy

Left Bundle Branch Area Pacing Using Conventional Stylet Driven Pacemaker Leads for Cardiac Resynchronization Therapy: a Randomized Study

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05365568
Acronym
LeCaRT
Enrollment
170
Registered
2022-05-09
Start date
2022-09-01
Completion date
2028-09-30
Last updated
2024-09-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure with Reduced Ejection Fraction

Brief summary

The aim of this study proposal is to compare the effectiveness of two distinct pacing modalities for cardiac resynchronization therapy. Our primary hypothesis is that left bundle branch area pacing (LBBAP) using conventional stylet driven pacemaker leads is an effective resynchronization method that yield to at least similar clinical benefits and outcomes when compare to biventricular pacing.

Detailed description

Recently some retrospective or uncontrolled studies were published that compared cardiac resynchronization therapy (CRT) using left bundle branch area pacing (LBBAP) and biventricular pacing (BiV), although with a limited number of patients. Moreover, only one of these studies compared LBBAP + right ventricle stimulation to conventional BiV stimulation prospectively. None of the studies used conventional stylet-driven pacemaker leads for LBBAP. Therefore, the present trial aims to fill-in the gap in the current literature regarding LBBAP for CRT and provide a first randomized head-to-head comparison against CRT. The aim of this study proposal is to compare the effectiveness of two distinct pacing modalities for cardiac resynchronization therapy. Our primary hypothesis is that left bundle branch area pacing (LBBAP) using conventional stylet driven pacemaker leads is an effective resynchronization method that yields to at least similar clinical benefits and outcomes when compared to biventricular pacing. The study is a multicentre, randomized trial comparing LBBAP against biventricular pacing. After characterization of the type device implanted (Pacing or Defibrillator), randomization will occur between both groups in a 1:1 ratio. The trial purpose is to demonstrate the efficacy of LBBAP to treat clinical heart failure in-patient indicated to receive a CRT.

Interventions

Left bundle branch area pacing using conventional stylet driven pacemaker leads for cardiac resynchronization therapy

PROCEDUREBiventricular pacing (BiV)

Cardiac resynchronization therapy (CRT) using biventricular pacing (BiV)

Sponsors

AZ Sint-Jan AV
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Aged 18 or above * Left Ventricular Ejection Fraction (LVEF) and NYHA meeting one off the previous indications documented with transthoracic echocardiography (TTE) no later than 3 months before randomization. * New York Heart Association (NYHA) class II-IV * Baseline left bundle branch block and QRS >130ms or QRS >150ms of any morphology or a wide paced QRS duration.

Exclusion criteria

* Younger than 18 years old * Pregnancy * Any unstable medical condition, life expectancy < 12 months * Inability to provide consent or to undergo follow-up * Narrow QRS duration (≤130ms) or prolonged QRS duration with typical Right Bundle Branch Block (RBBB) morphology on 12 lead ECG and sinus rhythm. * Significant hypertrophic cardiomyopathy - any septum abnormality contra-indicating LBBAP implantation (according to physician's evaluation) * Patients who are unable to perform a 6 minute walk test (6MWT) Note: patients should be able to perform a 6 minute walk test, but it is not a requirement to have the test performed before the procedure (e.g. due to inability of planning).

Design outcomes

Primary

MeasureTime frameDescription
Number of days elapsed from study procedure to first occurrence of one of the following events (combined endpoint) or to study close-out in the total patient population.12 monthsFirst occurrence of one of the following clinical events: death, hospitalization or unscheduled visit for heart failure (HF) or worsening HF symptoms with adaptation of the medical therapy, implant failure for any cause, implantable electronic cardiac device (IECD) re-intervention for any reason during follow-up (Lead Dislocation/phrenic nerve stimulation…)

Secondary

MeasureTime frameDescription
Improvement of procedural characteristics: Operative and fluoroscopic times1 dayImprovement of procedural characteristics: Operative and fluoroscopic times
Correction of electrical desynchrony post-implant1/6/12 monthsCorrection of electrical desynchrony post-implant, at 1/6/12 months
Clinical functional response (6MWT)6 monthsClinical functional response as evaluated by the improvement of the 6 Minutes Walk Test (6MWT) at 6 months follow-up
Left ventricular reverse remodelling6/12 monthsLeft ventricular reverse remodelling at 6 and 12 months follow-up as evaluated by the reduction of the Left Ventricular End-systolic Volume (LVESV) using trans-thoracal echocardiography
Implantable cardioverter defibrillator (ICD) therapies6/12 monthsICD therapies at 6 and 12 months

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026