Skip to content

IonMAN Trial- First in Human Study of the IoNIR Ridaforolimus-Eluting Coronary Stent System

IonMAN Trial-First in Human Study of the IoNIR Ridaforolimus-Eluting Coronary Stent System

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05364697
Acronym
IonMAN
Enrollment
60
Registered
2022-05-06
Start date
2022-08-30
Completion date
2029-12-31
Last updated
2024-11-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiovascular Diseases, Coronary Disease, Coronary Stenosis, Non-ST Elevated Myocardial Infarction

Brief summary

This is a prospective, multi-center, single-arm, open-label, First in Human clinical trial to provide preliminary evidence for the safety and efficacy of the novel IoNIR stent system.

Interventions

The IoNIR Ridaforolimus-Eluting Coronary Stent System is a sterile single-use device/drug combination product, comprised of a cobalt chromium (CoCr) alloy-based stent coated with a bioresorbable polymer mesh which is embedded with drug, mounted on a Rapid Exchange (RX) delivery system.

Sponsors

Medinol Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age ≥18 years. 2. Patient with an indication for PCI including NSTEMI (biomarkers have peaked or are falling), angina (stable or unstable), silent ischemia (in absence of symptoms a visually estimated target lesion diameter stenosis of ≥70%, a positive non-invasive stress test, or FFR ≤0.80, Pd/Pa≤0.91or iFR, RFR, DFR, DPR≤0.89 must be present). 3. Non-target vessel PCIs are allowed if performed \>30 days prior to index procedure. 4. Patient or legal guardian is willing and able to provide informed written consent and comply with follow-up visits and testing schedule. 5. Staged procedures are allowed as long as the IoNIR stent is implanted in the last procedure and at least 30 days have elapsed between the previous procedure and the IoNIR PCI. 6. One de novo target lesion ONLY may be treated (more than one lesion separated by less than 5 mm are considered one lesion). 7. Target lesion must be in a major native coronary artery with visually estimated diameter of ≥2.5 mm to ≤4.0 mm and lesion length of up to 28 mm, and appropriate size IoNIR stent is available

Exclusion criteria

1. ST Segment Elevation MI within past 30 days. 2. NSTEMI with biomarkers that have not peaked. 3. Significant valvular disease or planned valvular intervention. 4. PCI within the 30 days preceding the baseline procedure. 5. PCI in the target vessel within 12 months of the baseline procedure. 6. Planned staged procedures (coronary or valvular), where the study stent is implanted in the first stage. 7. Brachytherapy in conjunction with the baseline procedure. 8. Known history of stent thrombosis. 9. Cardiogenic shock (defined as persistent hypotension (systolic blood pressure \<90 mm/Hg for more than 30 minutes) or requiring pressors or hemodynamic support, including IABP. 10. Subject is intubated. 11. Known LVEF \<30%. 12. Relative or absolute contraindication to DAPT for 6 months in non-ACS patients and 12 months in ACS patients (including planned surgeries that cannot be delayed). 13. Subject has an indication such as atrial fibrillation for oral anticoagulation/prolonged heparinization (i.e., use of coumadin/DOAC (NOAC) or prolonged enoxaparin/heparin therapy is not allowed). 14. eGFR \<60 mL/min. 15. Hemoglobin \<10 g/dL. 16. Platelet count \<100,000 cells/mm3 or \>700,000 cells/mm3. 17. White blood cell (WBC) count \<3,000 cells/mm3. 18. Clinically significant liver disease. 19. Active peptic ulcer or active bleeding from any site 20. Bleeding from any site within the previous 8 weeks requiring active medical or surgical attention. 21. If femoral access is planned, significant peripheral arterial disease which precludes safe insertion of a 6F sheath. 22. History of bleeding diathesis or coagulopathy and patients that refuse blood transfusions. 23. Cerebrovascular accident or transient ischemic attack within the past 6 months, or any permanent neurologic defect attributed to CVA. 24. Known allergy to the study stent components (cobalt, nickel, chromium, molybdenum, PDLG, PLC, or limus drugs (ridaforolimus, zotarolimus, tacrolimus, sirolimus, everolimus, or similar drugs or any other analogue or derivative or similar compounds). 25. Known allergy to protocol-required concomitant medications such as aspirin, or P2Y12 inhibitors (clopidogrel, prasugrel, and ticagrelor), heparin and bivalirudin, or iodinated contrast allergy that cannot be adequately pre-medicated. 26. Any co-morbid condition that may cause non-compliance with the protocol (e.g., dementia, substance abuse, etc.) or reduced life expectancy to \<24 months (e.g., cancer, severe heart failure, severe lung disease). 27. Patient is participating in or plans to participate in any other investigational drug or device clinical trial that has not reached its primary endpoint. 28. Women who are pregnant or breastfeeding. 29. Women who intend to become pregnant within 12 months after the baseline procedure (women of child-bearing potential who are sexually active must agree to use a reliable method of contraception from the time of screening through 12 months after the baseline procedure). 30. Patient has received an organ transplant or is on a waiting list for an organ transplant. 31. Patient is receiving or scheduled to receive chemotherapy within 30 days before or any time after the baseline procedure. 32. Patient is receiving oral or intravenous immunosuppressive therapy or has known life-limiting immunosuppressive or autoimmune disease (e.g., HIV). Corticosteroids are allowed 33. More than one lesion of greater than 50% stenosis in the target vessel. 34. Complex lesions including severely calcified lesions, lesions requiring scoring/cutting and/or rotational/orbital atherectomy and/or intra-vascular lithotripsy, presence of visible thrombus, chronic total occlusions, bifurcation lesions (side branch diameter ≥2.0 mm), tortuous lesions, restenotic lesions, left main lesions, ectasia, aneurysm and any bypass graft lesions. 35. Another lesion in a target or non-target vessel (including all side branches) is present that requires or has a high probability of requiring PCI within 12 months after the baseline procedure. 36. Ostial lesions within 3 mm of LAD, LCx, RCA ostia, lesions in the LM

Design outcomes

Primary

MeasureTime frameDescription
1In-stent Late Loss (LL)1 yearIn-stent Late Loss (LL) at 1 year (cohort B) assessed by quantitative coronary angiography (QCA) (Minimal Lumen Diameter (MLD) post-procedure - MLD follow-up)
Target Lesion Failure1 yearTarget Lesion Failure (composite of cardiovascular death, target vessel-related myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year

Secondary

MeasureTime frameDescription
Cardiovascular death30 days, 6 months, 1, 2, 3, 4, 5 yearsCardiovascular death.
Myocardial infarction30 days, 6 months, 1, 2, 3, 4, 5 yearsMyocardial infarction.
Target vessel related MI30 days, 6 months, 1, 2, 3, 4, 5 yearsTarget vessel related MI.
Target Lesion Failure6 months, 2, 3, 4, 5 yearsTarget Lesion Failure (TLF)
Ischemia-driven TLR30 days, 6 months, 1, 2, 3, 4, 5 yearsIschemia-driven Target Lesion Revascularization
Ischemia-driven Target Vessel Revascularization30 days, 6 months, 1, 2, 3, 4, 5 yearsIschemia-driven Target Vessel Revascularization.
Stent thrombosis30 days, 6 months, 1, 2, 3, 4, 5 yearsStent thrombosis (ARC-2 definite and probable)
Acute Device Successindex procedureAcute Device Success (successful crossing and deployment with residual QCA DS \<30%).
Luminal gainCohort A: 30 days Cohort B: 12 monthsLuminal gain (MLD post-procedure - MLD pre-procedure).
In-stent MLDCohort A: 30 days Cohort B: 12 monthsIn-stent Minimal Lumen Diameter
In-segment MLDCohort A: 30 days Cohort B: 12 monthsIn-segment (+5mm from the stent edges) MLD
In-segment late lossCohort A: 30 days Cohort B: 12 monthsIn-segment (+5mm from the stent edges) late loss
Proximal late lossCohort A: 30 days Cohort B: 12 monthsProximal late loss (+5 mm from proximal stent edge)
Distal late lossCohort A: 30 days Cohort B: 12 monthsDistal late loss (+5 mm from distal stent edge)
In-stent and in-segment Binary RestenosisCohort A: 30 days Cohort B: 12 monthsIn-stent and in-segment Binary Restenosis.
OCT-determined inner layer percent neointimal hyperplasia volumeCohort A: 30 days Cohort B: 12 monthsCT-determined inner layer percent neointimal hyperplasia volume.
Major adverse cardiac events30 days, 6 months, 1, 2, 3, 4, 5 yearsMajor adverse cardiac events (MACE; the composite rate of cardiovascular death, any MI or ischemia-driven target lesion revascularization (TLR))
In-segment minimum lumen areaCohort A: 30 days Cohort B: 12 monthsIn-segment minimum lumen area (MLA)
Minimal stent areaCohort A: 30 days Cohort B: 12 monthsMinimal stent area (MSA)
Stent expansionCohort A: 30 days Cohort B: 12 monthsStent expansion.
Edge dissectionCohort A: 30 days Cohort B: 12 monthsEdge dissection.
NIH percentage at the MLACohort A: 30 days Cohort B: 12 monthsNIH (Neointimal hyperplasia) percentage at the MLA
Percentage of Area stenosis at the MLACohort A: 30 days Cohort B: 12 monthsPercentage of Area stenosis at the MLA.
In-stent late loss MLACohort A: 30 days Cohort B: 12 monthsIn-stent late loss MLA.
In-segment (+5 mm from the stent edges) late loss (MLA)Cohort A: 30 days Cohort B: 12 monthsIn-segment (+5 mm from the stent edges) late loss (MLA).
Proximal late loss (+5 mm from proximal stent edge) (MLA)Cohort A: 30 days Cohort B: 12 monthsProximal late loss (+5 mm from proximal stent edge) (MLA).
Distal late loss (+5 mm from distal stent edge) (MLA)Cohort A: 30 days Cohort B: 12 monthsDistal late loss (+5 mm from distal stent edge) (MLA).
Intraluminal mass at least 0.2 mm beyond the luminal edge of a strutCohort A: 30 days Cohort B: 12 monthsIntraluminal mass at least 0.2 mm beyond the luminal edge of a strut (Intraluminal mass attached to the vessel is defined as an irregularly shaped structure in contact with the luminal contour, a free intraluminal mass is defined as an isolated structure in the lumen without contact to the vessel wall)
MalappositionCohort A: 30 days Cohort B: 12 monthsMalapposition (stent struts clearly separated from the vessel wall (lumen border/plaque surface) without tissue behind the struts with a distance from the adjacent intima of ≥0.2 mm not associated with any side branch)
Percentage of Covered strutCohort A: 30 days Cohort B: 12 monthsPercentage of Covered strut (NIH thickness of \>0 μm)
Percentage of Healthy covered strutCohort A: 30 days Cohort B: 12 monthsPercentage of Healthy covered strut (NIH thickness≥40 μm)
Peri-strut low intensity areaCohort A: 30 days Cohort B: 12 monthsPeri-strut low intensity area (peri-strut region of homogeneous lower intensity observed without signal attenuation)
Healing scoreCohort A: 30 days Cohort B: 12 monthsHealing score (defined as % intraluminal mass \[=intraluminal mass volume/stent volume\] ×4 + % malposed and uncovered struts ×3 + (% uncovered struts alone ×2 + % malposed struts alone ×1) 1. Intraluminal mass (+4). 2. Malposed and uncovered struts (+3). 3. Uncovered struts alone (+2). 4. Malposed struts alone (+1)
In-stent MLACohort A: 30 days Cohort B: 12 monthsIn-stent Minimum Lumen Area
All-cause mortality30 days, 6 months, 1, 2, 3, 4, 5 yearsAll-cause mortality.

Countries

Brazil, Israel

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026