Skip to content

MyoVista wavECG Clinical Evaluation: >=60 y/o Enrichment Population

MyoVista wavECG Clinical Evaluation: >=60 y/o Enrichment Population

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05364541
Enrollment
50
Registered
2022-05-06
Start date
2022-06-01
Completion date
2023-11-30
Last updated
2023-09-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Screening

Brief summary

This is a single-center, interventional, single arm clinical study of the MyoVista wavECG for the detection of LV relaxation abnormalities. The study will be conducted at a single investigational site within the United States. Study subjects will predominately be screened from among those who have been enrolled in prior registry studies by the institution.

Detailed description

The study has a planned enrollment of at least 50 subjects to obtain approximately 40 subjects with a normal septal and lateral e' value on echocardiogram. The criteria defined as septal e'\< 7 cm/s or lateral e'\< 10 cm/s for relaxation abnormality based on ASE/AECVI guidelines will be used for the evaluation of LV diastolic function which is associated with abnormal relaxation in echocardiography. An independent Core Lab will verify all septal and lateral e' values on the site-acquired echocardiograms and these Core Lab measurements will serve as the ground truth standard with regard to the presence of LV relaxation abnormalities. Analysis of data from a prior multi-center study has revealed good correlation between the MyoVista wavECG results and echocardiography for the presence of LV relaxation abnormalities. This current study (HS-CLINVAL-002) is intended to supplement data collected in prior and ongoing studies, namely HS-CLINVAL-001, by recruiting individuals who are \>60 years old and who are anticipated to have normal echocardiogram results based on a screening of selected clinical characteristics. Subjects in this study will be invited to participate and receive non-standard-of-care echocardiograms and a study driven MyoVista test. The study will continue to focus on LV relaxation abnormalities by gathering additional device validation data for the purposes of regulatory approval peer-reviewed publications. Echocardiograms of study subjects will be used to compare/validate the study findings.

Interventions

DEVICEMyoVista wavECG

A standard 12-Lead, multi-channel resting interpretive trans-thoracic electrocardiograph providing both a Glasgow Interpretive Analysis and unique MyoVista wavECG Information for the detection of Left Ventricular Diastolic Dysfunction.

Sponsors

Heart Test Laboratories, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
60 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Subject is \>=60 years of age * Subjects will predominately be recruited among those who are already enrolled in existing registry studies within the institution. * The subject provides written informed consent using an Informed Consent Form that is reviewed and approved by the site's Institutional Review Board (IRB). * Conventional ECG results show a sinus rhythm and no other contraindicated rhythm abnormalities (see exclusions below).

Exclusion criteria

* The subject has current acute coronary syndrome, decompensated heart failure or stroke * The subject has received any prior cardiac interventions or surgical therapeutic procedures relating to cardiac abnormalities: valve replacement, pacemaker implantation, coronary artery bypass grafting (CABG), heart transplant, ablation, coronary stent placement, etc. * Conventional ECG results indicating a lack of sinus rhythm and/or any other contraindicated rhythm abnormalities, including: active atrial fibrillation or atrial flutter, left anterior fascicular block, left and/or right bundle branch block * The subject is pregnant at the time of the study testing * The subject has chest deformities that interfere with accurate measurement of ECG (either conventional or wavECG) * Subjects with central nervous system or musculoskeletal abnormalities that may interfere with accurate acquisition of ECG and/or echocardiogram measurements. * The subject is enrolled in another clinical study that may interfere with MyoVista or echocardiogram measurements. Exceptions to this may be approved by HeartSciences.

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic PerformanceBaselineSensitivity and specificity of the MyoVista for the classification of Low e' where a positive includes a MyoVista wavECG result of Positive and Highly Positive. The study result will be considered to have achieved the pre-specified performance criteria for success if the sensitivity is demonstrated to exceed 70% and the specificity is demonstrated to exceed 70%.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026