Accuracy of Handheld and Non-contact Tonometry

Accuracy of Handheld and Non-contact Tonometry in Clinical Practice

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05352906
Enrollment
300
Registered
2022-04-29
Start date
2022-04-20
Completion date
2023-01-30
Last updated
2022-04-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glaucoma, Glaucoma, Suspect, Intraocular Pressure

Keywords

Glaucoma, Suspect, Tonometer, Air-puff

Brief summary

Monitoring the intraocular pressure (IOP) is one of the most important tests used in follow-up among glaucoma suspects and confirmed glaucomatous patients.

Detailed description

In tertiary hospitals, IOP screening is an important tool to confirm glaucomatous eyes. Inaccurate measurements may lead to missed diagnosis or false positive results that may affect patients' quality of life. There are many devices produced to measure IOP, the commonest one is Goldman contact tonometry, the aim of this study is to compare the results of new developed tonometers to the standard applanation tonometer.

Interventions

DIAGNOSTIC_TESTIntraocular pressure

Measurements of intraocular pressure in millimeter mercury (mmHg).

Sponsors

Benha University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* All subjects seeking regular check-up in glaucoma clinic at banha university hospital. * Glaucoma suspects and glaucomatous patients that visit glaucoma clinic for regular IOP measurements.

Exclusion criteria

* Patients that will refuse to measure IOP again with other devices. * patients with previous corneal surgeries or scar that may alter the measurements of the tonometer s (as previous keratoplasty, trauma or opacities).

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of air-puff tonometryImmediately after goldman applanation tonometry test for each eye.Comparing IOP measurements in (mmHg) between standard goldman applanation tonometry and air-puff non-contact tonometry.

Secondary

MeasureTime frameDescription
Accuracy of handheld tonometryImmediately after goldman applanation tonometry test for each eye.Comparing IOP measurements in (mmHg) between standard goldman applanation tonometry and handheld contact tonometry.

Countries

Egypt

Contacts

Primary ContactAhmed Abdelshafy, MD
ahmad4lg@gmail.com01222328766

Outcome results

None listed