Morphological Changes of Ciliary Body and Trabecular Meshwork

In Vivo Morphological Changes of Ciliary Body and Trabecular Meshwork in High Myopia Eyes With Open-angle Glaucoma in Their Accommodation Induced by Pilocarpine

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05352854
Enrollment
120
Registered
2022-04-29
Start date
2022-05-01
Completion date
2022-08-31
Last updated
2022-04-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glaucoma, Myopia

Keywords

ciliary body and trabecular meshwork

Brief summary

Glaucoma is the leading cause of irreversible blindness worldwide. Although the pathogenesis remains unclear, pathologic increase in intraocular pressure (IOP) due to blocked aqueous outflow through the trabecular-Schlemm canal is known to be an important risk factor, and reduction of IOP is the only clinically validated way to retard the progression of OAG. Ciliary muscle plays a central role in the trabecular meshwork-Schlemm canal outflow pathway. Clinical evidence suggests that ciliary muscle contraction stimulated by cholinergic receptor agonist and retraction of ciliary body position after cataract surgery can dilate the lumen of Schlemm canal and reduce IOP. Currently, Ultrasound biomicroscopy (UBM) can obtain two-dimensional images of the anterior segment using high-frequency Ultrasound transducers in medical imaging studies of the ciliary body - trabecular meshwork -Schlemm canal complex. UBM has better tissue penetration than Optical coherence tomography (OCT) and can image the ciliary body better, but it has a lower resolution (30um to 50um) and is poor at imaging tiny tissues such as trabecular meshwork and Schlemm canal. The latest swept-source OCT (SS-OCT) has faster image capture rate (1000000 A scans/SEC), stronger penetration and higher resolution (8um axial resolution and 20um transverse resolution). The structure and morphology of ciliary body-trabecular meshwork-Schlemm canal complex can be clearly photographed. The investigators intend to use CASIA2 to image the ciliary body-trabecular meshwork-Schlemm canal complex before and after administration of pilocarpine in healthy individuals and patients with glaucoma to assess the effect of pilocarpine on the anatomy of the ciliary body-trabecular meshwork-Schlemm canal complex.

Detailed description

Glaucoma is the leading cause of irreversible blindness worldwide. Although the pathogenesis remains unclear, pathologic increase in intraocular pressure (IOP) due to blocked aqueous outflow through the trabecular-Schlemm canal is known to be an important risk factor, and reduction of IOP is the only clinically validated way to retard the progression of OAG. Ciliary muscle plays a central role in the trabecular meshwork-Schlemm canal outflow pathway. When the ciliary muscle contraction, the elastic fiber network will pull trabecular meshwork away from Schlemm canal direction, trabecular meshwork and adjacent tissue gap increases, increasing aqueous outflow. Clinical evidence suggests that ciliary muscle contraction stimulated by cholinergic receptor agonist and retraction of ciliary body position after cataract surgery can dilate the lumen of Schlemm canal and reduce IOP. Currently, Ultrasound biomicroscopy (UBM) can obtain two-dimensional images of the anterior segment using high-frequency Ultrasound transducers in medical imaging studies of the ciliary body - trabecular meshwork -Schlemm canal complex. UBM has better tissue penetration than Optical coherence tomography (OCT) and can image the ciliary body better, but it has a lower resolution (30um to 50um) and is poor at imaging tiny tissues such as trabecular meshwork and Schlemm canal. The latest swept-source OCT (SS-OCT) has faster image capture rate (1000000 A scans/SEC), stronger penetration and higher resolution (8um axial resolution and 20um transverse resolution). The structure and morphology of ciliary body-trabecular meshwork-Schlemm canal complex can be clearly photographed. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can accurately image the ciliary body-trabecular meshwork-Schlemm canal complex. The investigators intend to use CASIA2 to image the ciliary body-trabecular meshwork-Schlemm canal complex before and after administration of pilocarpine in healthy individuals and patients with glaucoma to assess the effect of pilocarpine on the anatomy of the ciliary body-trabecular meshwork-Schlemm canal complex.

Interventions

DRUG0.5% pilocarpine eye drops

Subjects will be given 0.5% pilocarpine eye drops every five minutes for three times and wait for 40 minutes

Sponsors

Yune Zhao
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* Emmetropia/low myopia,high myopia, primary open-angle glaucoma without high myopia, and high myopia with primary open-angle glaucoma * have a good gaze to complete the test required inspection;

Exclusion criteria

* hypersensitivity to pilocarpine * History of eye surgery, including cataract surgery, anti-glaucoma surgery, corneal surgery, retinal surgery, and eye trauma * history of systemic diseases that may affect the eyes (such as diabetes, hypertension, etc.) * intraocular chronic inflammatory diseases (uveitis, etc.), retinal diseases (retinal detachment, diabetic retinopathy, retinitis pigmentosa, etc.) * Corneal scars and severe cataracts affect OCT imaging * Eye diseases (angle-closure glaucoma, abnormal anterior segment development, neovascularization, etc.) that can affect trabecular meshwork and Schlemm canal structure.

Design outcomes

Primary

MeasureTime frameDescription
Morphology of ciliary bodybaseline, pre-intervention(local application of pilocarpine eye drops)measurement of Morphology of ciliary body using CAISA2(The novel anterior segment optical coherence tomography (AS-OCT) device) and Image J software
Morphology of trabecular meshworkbaseline, pre-intervention(local application of pilocarpine eye drops)measurement of Morphology of trabecular meshwork using CAISA2(The novel anterior segment optical coherence tomography (AS-OCT) device) and Image J software