Skip to content

Evaluating Implant Stability Using Three Devices Osstell®, Periotest® and AnyCheck®

Evaluating Implant Stability Using Three Devices Osstell®, Periotest® and AnyCheck®: A Prospective Observational Clinical Study.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05340959
Enrollment
16
Registered
2022-04-22
Start date
2021-12-15
Completion date
2022-12-01
Last updated
2023-10-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Edentulous Alveolar Ridge

Brief summary

A prospective observational study guided by the guidelines of Strengthening The Reporting Of Observational Study in Epidemiology (STROBE) in 2014, that will be conducted to evaluate implant stability using three devices; Osstell®, Peiotest® and AnyCheck® and comparing the results.

Detailed description

In this study, 40 dental implants will be installed in osteotomy sites for patients with single or multiple missing tooth or teeth based on radiographic findings (CBCT). The primary stability will be measured immediately after implant installation using three devices : 1. Osstell : based on resonance frequency analysis (RFA). 2. Periotest: based on damping effect. 3. AnyCheck: based on tapping motion. Secondary stability will be measured after 12 weeks using the same devices mentioned above.

Interventions

DEVICEDevices: Osstell®, Periotest® and AnyCheck®.

1. Osstell®: is a device that measure implant stability and based on resonance frequency analysis (RFA). Due to stiffness in the interface between the implant surface and the bone smart peg will vibrates accordingly. the more dense bone the higher stability, the higher frequency and higher Implant Stability Quotient (ISQ) value which is from 1-100. 2. Periotest®: is a device used to assess osseointegration of dental implants, so it measure implant stability . it is based on damping effect of implant. Showing the measurement digitally on a scale from -8 (low mobility) to 50 (high mobility) PTV units. 3. AnyCheck®: this is an implant stability meter that measures the stiffness of alveolar bone-implant interface through a tapping motion. Showing the measurement on a scale from 30 (low stability) to 85 (high stability).

Sponsors

University of Baghdad
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Healthy patients over 18 years of either gender, having single or multiple missing teeth in the maxilla and/or mandible. 2. Patient with adequate vertical bone height and width for implant placement based on preoperative radiographic findings (CBCT). 3. Ability to tolerate conventional surgical and restorative procedures. 4. Patients who are willing to comply with the study and give their consent.

Exclusion criteria

1. Active infection or inflammation in the implant zone. 2. Presence of any uncontrolled systemic diseases. 3. Patients with a history of radiotherapy to the head and neck. 4. Any patient requires advanced and complicated surgical techniques such as sinus lift and bone graft.

Design outcomes

Primary

MeasureTime frameDescription
Implant stability measured by Osstell®.Changes in implant stability from baseline value measured immediately after implant installation (primary stability) and after 12 weeks (secondary stability).Implant stability will be measured by: Osstell® (RFA) that is measured by Implant Stability Quotient (ISQ) Value.
Implant stability measured by Periotest®.Changes in implant stability from baseline value measured immediately after implant installation (primary stability) and after 12 weeks (secondary stability).Implant stability will be measured by: Periotest® (damping effect) that is measured by Periotest Value (PTV).
Implant stability measured by AnyCheck®.Changes in implant stability from baseline value measured immediately after implant installation (primary stability) and after 12 weeks (secondary stability).Implant stability will be measured by: AnyCheck® (tapping-motion) that is measured by Initial Stability Test (IST) Value.
Correlation between values obtained by the devicesChanges in implant stability from baseline value measured immediately after implant installation (primary stability) and after 12 weeks (secondary stability).Correlation between values obtained by: 1. Osstell® (RFA): measured by Implant Stability Quotient (ISQ) Value. 2. Periotest® (damping effect): measured by Periotest Value (PTV). 3. AnyCheck® (tapping-motion): measured by Initial Stability Test (IST) Value.

Countries

Iraq

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026