Skip to content

The Accuracy of Detection of Artificial Intelligence Second Mesio-buccal Canal of Maxillary First Molars on CBCT Images

The Accuracy of Computer Aided Detection of Second Mesio-buccal Canal of Maxillary First Molars on CBCT Images Using Deep Learning Model (Artificial Intelligence): Diagnostic Accuracy Study

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05340140
Enrollment
50
Registered
2022-04-21
Start date
2022-05-31
Completion date
2023-10-31
Last updated
2022-04-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Artificial Intelligence

Brief summary

CAD systems are computer applications that assist in the detection and/or diagnosis of diseases by providing an unbiased second opinion to the image interpreter, aiming at improving accuracy and reducing time for analysis. With the rapid growth of Deep Learning (DL) algorithms in image-based applications, CAD systems can now be trained by DL to provide more advanced capability (ie, the capability of artificial intelligence \[AI\]) to best assist clinicians.

Detailed description

Countless studies and discussions have been based on the existence of a second canal in the mesiobuccal (MB) root of the maxillary molars , since it is strongly believed that one of the foremost reasons for endodontic failure in maxillary first molars is the difficulty of detecting and treating those second mesiobuccal (MB2) canals .The literature reveals that although MB2 canals of maxillary first molars have been found in more than 70% of in vitro studies , they were detected clinically in less than 40% of cases . Cone beam computed tomography (CBCT) is an imaging modality in the field of endodontics that has several advantages, including the ability to perform three-dimensional (3D) imaging of root canal systems with lower radiation doses, higher resolution, and no superimposition . Researchers have evaluated the efficiency of CBCT when it comes to identifying MB2 canals, and CBCT has been suggested to be a reliable method for the detection of these canals. However, in clinically relevant situations, such a smaller lesions on root-filled teeth, CBCT accuracy is greatly reduced (sensitivity 0.63, specificity 0.69) . Moreover, clinician dependent interpretation of CBCT imaging still suffers from low inter- and intra-observer agreement. Computer-aided detection and diagnosis (CAD) has been widely applied to biomedical image analysis outside of dentistry .

Interventions

DIAGNOSTIC_TESTdeep learning model

deep learning model developed by computer science expert and based on convolution neural network , and trained by our datasets.

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
OTHER

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* • CBCT scans showing erupted maxillary 1st molar. * Vovel size not exceeding 0.1mm. * Maxillary molars showing complete root formation. * Carious or Non-carious tooth.

Exclusion criteria

* • Maxillary first molars with developmental anomalies, external or internal root resorption, root canal calcification, previous root canal treatment, post restorations, and/or root caries. * CBCT images of sub-optimal quality or artifacts / high scatter interfering with proper assessment.

Design outcomes

Primary

MeasureTime frameDescription
accuracy of detection of MB2baselinedetection of MB2 on CBCT images of maxillary first molars using deep learning model

Countries

Egypt

Contacts

Primary ContactSally Mansour, Masters
sally.mansour@dentistry.cu.edu.eg+201019932383
Backup ContactAhmed MFM Magdy, MCS
ahmed_magdy@dentistry.cu.edu.eg+201019932383

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026