Skip to content

Radioisotope and Fluorescence Guidance in Rectal Cancer

Pelvic Side Wall Lymph Node Detection in Rectal Cancer Using Dual Radioisotope and Fluorescence Guidance

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05336643
Enrollment
10
Registered
2022-04-20
Start date
2023-01-31
Completion date
2024-04-30
Last updated
2022-11-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lymph Node Metastasis, Rectal Cancer

Brief summary

A study to investigate if pelvic side wall lymph nodes that remain after neo-adjuvant chemoradiotherapy can be identified intraoperatively using dual radioisotope and fluorescence guidance.

Detailed description

Background Total mesorectal excision (TME) revolutionised the management of rectal cancer by improving outcomes and standardising surgical technique. When excising mesorectal lymph nodes, most involved nodes are removed. However, a proportion of lower rectal lymphatic drainage is through the pelvic sidewall (PSW) system, all PSW nodes are left behind in TME. Up to 15% patients with rectal cancer have PSW involvement at presentation, this is associated with increased local recurrence. Problem There are two main approaches in the management of PSW nodes. In the Western hemisphere, patients are typically staged with pre-operative MRI. Those with nodes undergo neo-adjuvant chemoradiotherapy to downstage the tumour, followed by surgical resection, PSW lymph nodes are left in place. In the East patients undergo PSW lymph node dissection at the time of rectal resection. There is evidence that lymphadenectomy at initial surgery or after chemoradiotherapy improves oncological outcome, though this is at the cost of increased morbidity, worsening urinary and sexual function. Objective The aim is to make PSW lymph node dissection safer and more targeted. This initial feasibility study, is investigating if PSW lymph nodes can be individually identified using dual modalities, fluorescence, and a radioisotope tracer. The fluorophore indocyanine green (ICG) has been used successfully for lymph node mapping in rectal cancer. ICG and Technetium-99m nanocolloid (Tc99m), a radioisotope, have been used as dual tracers for lymph nodes in gynaecological, esophagogastric and oral surgery, but never in rectal surgery. Method The investigators have designed an open label, single-centre, feasibility study to investigate if PSW lymph nodes can be identified intra-operatively using a radioisotope and fluorescence. Ten post neo-adjuvant chemotherapy rectal cancer patients will be scheduled for resection. Pre-operatively patients will receive an injection of Tc99m and ICG to the submucosa around the tumour. Patients will undergo single-photon emission computed tomography (SPECT) scanning to identify lymphatic drainage. Intra-operatively, after bowel resection, the surgical team will examine the PSW for lymph nodes using a minimally invasive gamma probe (SENSEI, Lightpoint Medical) to detect Tc99m, and a near infrared camera system (Firefly, Intuitive) to visualise ICG. The primary outcome is intraoperative detection of PSW lymph nodes. Significance The aim from this feasibility study is to demonstrate that individual PSW nodes can be detected intra-operatively. By proving this technique, the investigators will design a larger study to investigate the oncological outcome of excising individual involved nodes, with the aim of reducing PSW recurrence and surgical morbidity.

Interventions

DEVICERadiofluorescence

Assessment of pelvic sidewall with Firefly and Sensei

Sponsors

University College, London
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Intervention model description

Open label, single arm, feasibility study for a medical device

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* 18 years of age or older * Primary diagnosis of biopsy-proven rectal cancer * Scheduled for curative robotic surgery of primary tumour * Have signed an approved informed consent form for the study * Be willing and able to comply with the study protocol

Exclusion criteria

* Known allergy or history of adverse reaction to Technetium-99m nanocolloid or indocyanine green * Pregnant or lactating subjects * Subjects who, in the Investigator's and/or designee's opinion, have any medical condition that makes the subject a poor candidate for the investigational procedure, or interferes with the interpretation of study results

Design outcomes

Primary

MeasureTime frameDescription
Lymph node detection with indocyanine green and near-infrared light source12 monthsIntraoperative identification of pelvic side wall lymph nodes using fluorescence. After resection of the rectal specimen the near infrared light source will be switched on and the pelvic side wall will be assessed for lymph nodes seen on SPECTCT. Primary outcome will be recorded as yes or no.
Lymph node detection with technetium 99m colloid and SENSEI gamma probe12 monthsIntraoperative identification of pelvic side wall lymph nodes using radioisotope. After resection of the rectal specimen the gamma probe will be switched on and the pelvic side wall will be assessed for lymph nodes seen on SPECTCT. Primary outcome will be recorded as yes or no.

Secondary

MeasureTime frameDescription
Time to lymph node identification (seconds)12 monthsUsability of drop in gamma probe - effectiveness 3 Intraoperative identification of pelvic side wall lymph nodes using radioisotope. After resection of the rectal specimen the gamma probe will be switched on and the pelvic side wall will be assessed for lymph nodes seen on SPECTCT. Secondary outcome is time taken for lymph node identification, recorded in seconds
Usability of drop in probe (System usability scale)12 monthsUsability of drop in gamma probe - satisfaction Intraoperative identification of pelvic side wall lymph nodes using radioisotope. After resection of the rectal specimen the gamma probe will be switched on and the pelvic side wall will be assessed for lymph nodes seen on SPECTCT. Secondary outcome is the usability of the SENSEI gamma probe using the System Usability Scale (Score 0-100)
Radioactive count of identified lymph nodes (MBq)12 monthsUsability of drop in gamma probe - effectiveness 1 Intraoperative identification of pelvic side wall lymph nodes using radioisotope. After resection of the rectal specimen the gamma probe will be switched on and the pelvic side wall will be assessed for lymph nodes seen on SPECTCT. Secondary outcome is the gamma radiation count of identified nodes recorded in megabecquerel (MBq)
Concordance of nodes seen on PET MRI/CT and SPECTCT12 monthsIn the lead up to surgery (\>24 hours prior) patients will undergo PET MRI/CT. In the morning patients receive a peritumoral submucosal injection of technetium 99m nano colloid. After a 4 hour interval they undergo SPECTCT. Percentage of nodes seen on PET MRI/CT seen on SPECTCT (%)
Lymph nodes identified on SPECTCT12 monthsIn the morning patients receive a peritumoral submucosal injection of technetium 99m nano colloid. After a 4 hour interval they undergo SPECTCT. Number of lymph nodes identified on SPECTCT.
Background radioactive count (MBq)12 monthsUsability of drop in gamma probe - effectiveness 2 Intraoperative identification of pelvic side wall lymph nodes using radioisotope. After resection of the rectal specimen the gamma probe will be switched on and the pelvic side wall will be assessed for lymph nodes seen on SPECTCT. Secondary outcome is the gamma radiation count of background radiation, measured underneath camera port, pointing up towards port, recorded in megabecquerel (MBq)

Countries

United Kingdom

Contacts

Primary ContactTom Pampiglione, BMBS
uclh.randd@nhs.net02034479928

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026