Follow-up Study to Monitor the Efficacy and Safety of the Occlutech® mVSD Cases

A Multicenter, International, Follow-up Study to Monitor the Efficacy and Safety of the Occlutech® Muscular Ventricular Septal Defect (mVSD) Occluder in Patients With Muscular Ventricular Septal Defects

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05329350
Acronym
mVSD Registry
Enrollment
50
Registered
2022-04-15
Start date
2022-03-03
Completion date
2031-06-01
Last updated
2026-07-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Muscular Ventricular Septal Defect

Keywords

mVSD Occluder, mVSD, Occlutech, Occlutech mVSD Occluder, Muscular ventricular septal defect closure, Transcatheter closure, Percutaneous occlusion, Periventricular closure, Post-market clinical follow-up, PMCF, Congenital heart defect, Structural heart disease intervention, Echocardiography follow-up

Brief summary

The Occlutech® mVSD is indicated for percutaneous occlusion of hemodynamically or clinically significant muscular ventricular septal defects. The objectives of the study are: * To confirm the efficacy of Occlutech mVSD in patients requiring transcatheter occlusion (closure) of muscular ventricular septal defects. * To confirm the safety of Occlutech mVSD in patients requiring transcatheter occlusion (closure) of muscular ventricular septal defects.

Detailed description

This is a multicenter, prospective, and retrospective, international, post-market clinical follow-up Study to monitor the efficacy and safety of the Occlutech mVSD in patients with muscular ventricular septal defects. Safety and efficacy of implanted devices are assessed by echocardiography, vital signs, laboratory tests, and ECGs on Day 1 (within 48 hours post-procedure), follow-up 1 (between Day 30 and Day 60), follow-up 2 at 6 months (from Day 61 until 6 months), follow-up 3 at 1 year (from 6 months until 1 year), and follow-up 4 at 3 years (from 1 year until 3 years). * Patients will be screened to determine eligibility for the registry based on inclusion/exclusion criteria, through their medical history, demographics, vital signs, clinical laboratory tests, performance of a 12 lead electrocardiogram (ECG) and echocardiography data. * Participants are treated according to the instructions-for-use (IFU) of the device and according to clinical routine. * Procedures are performed at sites having appropriate laboratory support and adequately trained imaging personnel. The procedure is performed by physicians with experience in a wide range of interventional cardiology and structural heart disease, including transcatheter patent ductus arteriosus, atrial septal defect, and ventricular septal defect (VSD) closures. Recruitment will be open until 50 Patients have been enrolled. The primary safety endpoint is defined as the incidence of Serious Adverse Device Effects (SADEs) including procedure-related death, procedure-related stroke, ischemic stroke, systemic embolism, severe hemolysis, complete heart block requiring pacemaker implantation or device explanation, new onset of severe tricuspid regurgitation (TR), new the onset of severe aortic regurgitation (AR), severe right-left ventricular outflow obstruction (RVOTO-LVOTO), device embolization, cardiac tamponade, infective endocarditis, or vascular complications requiring open heart surgery up to 1 year after the mVSD closure procedure. The primary efficacy endpoints will include data obtained 1 year after the mVSD closure procedure for successful implantation of the device with a proper closure of the mVSD (defined as the reduction in muscular ventricular septal shunt to trivial or no shunt at all, as assessed by echocardiography pre- vs post-implantation).

Interventions

DEVICEOcclutech muscular ventricular septal defect (mVSD) Occluder

Percutaneous, transcatheter (catheter-based) non-surgical closure of a muscular ventricular septal defect (mVSD) using the Occlutech mVSD Occluder. The device is a self-expandable nitinol wire-mesh occluder with two retention discs connected by a flexible waist and incorporates polyester/PET patches to support defect occlusion and tissue ingrowth. Implantation is performed by experienced operators in a specialized cath lab according to the IFU and local routine; device sizing/selection is guided by imaging (e.g., transthoracic echocardiography, angiography, fluoroscopy). The system is deployed using compatible Occlutech delivery accessories (e.g., Occlutech Pistol Pusher and Occlutech Delivery Set \[ODS v1 or ODS III\], as applicable).

Sponsors

Occlutech International AB
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
3 Months to 80 Years
Healthy volunteers
No

Inclusion criteria

* A participant will be eligible for study participation if he/she meets the indication and area of application as laid down in the IFU. The Occlutech mVSD is indicated for percutaneous occlusion of hemodynamically or clinically significant muscular ventricular septal defects. * Any age * Male or female. * Patients understand the nature of the study and provide their informed consent to participation. * Patients willing and able to attend the follow-up visits and procedures foreseen by study CIP. Contraindication * Hemodynamically relevant VSD shunt * Congestive heart insufficiency * Recurrent respiratory infections * Failure to thrive. * Significant left ventricle (LV) enlargement * Significant left atrium (LA) enlargement * Other clinical indication

Exclusion criteria

The device is contraindicated for participants known to have any of the following: ⦁Active bacterial infections * Active infection at the time of implantation * Allergy to antiplatelet or anticoagulant therapy * Allergy to nickel and/or titanium and/or nickel/titanium-based materials * Any type of serious infection 1 month before the procedure * The aortic rim of less than 2 mm * Demonstrated intracardiac thrombi on echocardiography * Malignancy where life expectancy is less than 3 years * mVSD diameter \> 20 mm * Perimembranous VSD Post-MI VSD * Recent myocardial infarction or a surgical bypass operation in the last 30 days * Sepsis (local or generalized) * Septal thickness \> 7 mm in the area of the Occluder placement

Design outcomes

Primary

MeasureTime frameDescription
Percentage of Participants With at Least One Serious Adverse Device Effect (SADE) Within 12 Months After Occlutech mVSD ImplantationUp to 12 months post-procedureSerious Adverse Device Effects (SADEs) include procedure-related death, stroke, systemic embolism, severe hemolysis, complete heart block requiring pacemaker implantation or device explantation, severe tricuspid regurgitation (TR), severe aortic regurgitation (AR), right ventricular outflow tract obstruction (RVOTO), left ventricular outflow tract obstruction (LVOTO), device embolization, cardiac tamponade, infective endocarditis, or vascular complications requiring open-heart surgery.
Percentage of Participants With Successful Device Implantation and Trivial or No Residual Ventricular Septal Shunt at 12 Months12 months post-procedureSuccessful implantation of the Occlutech mVSD Occluder with effective closure defined as reduction of the muscular ventricular septal shunt to trivial or no residual shunt, as assessed by echocardiography.

Secondary

MeasureTime frameDescription
Percentage of Participants With at Least One Serious Adverse Device Effect (SADE) Between 1 and 3 Years After Occlutech mVSD Implantation1 year to 3 years post-procedureIncidence of Serious Adverse Device Effects (SADEs) occurring more than 1 year and up to 3 years after the procedure, including procedure-related death, stroke, systemic embolism, severe hemolysis, complete heart block requiring pacemaker implantation or device explantation, severe TR, severe AR, RVOTO, LVOTO, device embolization, cardiac tamponade, infective endocarditis, or vascular complications requiring open-heart surgery.
Percentage of Participants With Minor Complications, Including Transient Hemolysis and Non-Surgical Vascular Complications, Up to 3 YearsUp to 3 years post-procedureMinor complications include transient hemolysis, vascular complications not requiring surgery, and other clinically relevant minor complications as assessed by the investigator.