A Dual Tandem Study - SC vs. CAD-EYE vs. CAD-EYE With G-EYE

A Dual Tandem Study Comparing the Adenoma Detection and Miss-rate of SC to That of Artificial Intelligence (CAD-EYE) Aided Colonoscopy and to That of Artificial Intelligence (CAD-EYE) and G-EYE® Aided Colonoscopy.

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05318495
Enrollment
372
Registered
2022-04-08
Start date
2022-03-01
Completion date
2022-12-31
Last updated
2022-04-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Adenoma, Colo-rectal Cancer

Brief summary

Single-center, four-arm dual-tandem, randomized, open-label study involving the following devices: 1. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI). 2. CAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas. 3. The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning.

Detailed description

Single-center, four-arm dual-tandem, randomized, open-label study involving the following devices: 1. The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI). 2. CAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas. 3. The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning. Total of up to 372 patients will be randomized,186 to each of the two tandems

Interventions

DEVICEStandard Colonoscopy

The Standard Colonoscope is a high-definition colonoscope employing advanced optical filtering and enhancement techniques - blue light imaging (BLI) and linked color imaging (LCI).

DEVICECAD-EYE

CAD-EYE is an artificial intelligence software, used in real-time during the colonoscopy procedure for aiding the identification and characterization of polyps and adenomas.

DEVICEG-EYE

The G-EYE® balloon is a reusable (reprocessable) balloon permanently installed on the distal tip of a standard colonoscope, and is also intended to assist in flattening colonic folds and control the colonoscope's field of view and tip positioning.

Sponsors

Dr. Horst Schmidt Klinik GmbH
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

1. Screening and surveillance population for Adenoma and CRC. 2. The patient must understand and sign a written informed consent for the procedure.

Exclusion criteria

1. Subjects with inflammatory bowel disease; 2. Subjects with a personal history of hereditary polyposis syndrome; 3. Subjects with suspected chronic stricture potentially precluding complete colonoscopy; 4. Subjects with diverticulitis or toxic megacolon; 5. Subjects with prior colonic surgery (exclusion appendectomy) 6. Subjects with a history of radiation therapy to abdomen or pelvis; 7. Pregnant or lactating female subjects; 8. Subjects who are currently enrolled in another clinical investigation. 9. Subjects with current oral or parenteral use of anticoagulants, not considered eligible by the investigator. 10. Subjects with recent (within the last 3 mounts) coronary ischemia or CVA (stroke) 11. Any patient condition deemed too risky for the study by the investigator

Design outcomes

Primary

MeasureTime frameDescription
Additional adenoma detection yield6 weeksadditional adenoma detection yield (represented by the miss rate) of CAD-EYE and G-EYE® colonoscopy over standard coloscopy compared to the additional adenoma detection yield of CAD-EYE aided colonoscopy over standard colonoscopy