Skip to content

PMCF Study for Peripheral Arteries Above the Knee (ATK)

A Retrospective PMCF Study Evaluating the Safety and Clinical Performance of the S.M.A.R.T. Flex Stent Iliac, S.M.A.R.T. Flex SFA/PP, S.M.A.R.T. Control Nitinol Stent, S.M.A.R.T. Nitinol Stent, PALMAZ Blue .018 Peripheral Stent on Slalom, PALMAZ Genesis .035 Peripheral Stent on Opta Pro, SABER OTW PTA Catheter, SABERX PTA Dilatation Catheter and PowerFlex Pro PTA Catheter for the Endovascular Interventions in the Ilio-femoropopliteal Vessels

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05312580
Enrollment
387
Registered
2022-04-05
Start date
2022-06-01
Completion date
2022-11-07
Last updated
2023-07-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Angiopathy, Peripheral, Femoropopliteal Stenosis, Peripheral Arterial Disease

Brief summary

The rationale of this study is to confirm and support the clinical safety and performance of the products in a real-word population of 350 patients who underwent an endovascular intervention within standard-of-care (SOC) of the ilio-femoropopliteal artery, using at least 1 of the products (named above) from Cordis US Corp.

Interventions

None listed

Sponsors

FCRE (Foundation for Cardiovascular Research and Education)
CollaboratorOTHER
Cordis US Corp.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patient is \>18 years old at conduction of the procedure. 2. Patient who underwent endovascular procedure of the ilio-femoropopliteal vessel with at least one of the following the S.M.A.R.T. Flex Stent Iliac and/or S.M.A.R.T. Flex SFA/PP and/or S.M.A.R.T. Control Nitinol Stent and/or S.M.A.R.T. Nitinol Stent and/or PALMAZ Blue .018 Peripheral Stent on Slalom and/or PALMAZ Genesis .035 Peripheral Stent on Opta Pro and/or SABER OTW PTA Catheter and/or SABERX PTA Dilatation Catheter and/or PowerFlex Pro PTA Catheter as described in the IFU of the devices. 3. Target Lesion is located in the ilio-femoropopliteal vessels.

Exclusion criteria

1. Anatomy or size of vessels that did not allow appropriate usage of the devices, following IFU of the devices. 2. Known contraindication and/or allergy to (a component of) the device as described in the IFU of the devices. 3. Women who were pregnant or lactating at the time of the procedure. 4. Life expectancy of less than 12 months at the time of procedure. 5. Any patient who was hemodynamically unstable at onset of procedure.

Design outcomes

Primary

MeasureTime frameDescription
Freedom from Serious Adverse Events30 daysAcute primary Safety Endpoint: Freedom from Serious Adverse Events (SAEs) and Serious Adverse Device Effect (SADEs) during the procedure and up to 30 days after the procedure.
Technical success rateDuring the procedureAcute Primary Efficacy Endpoint: Technical success rate defined as successful crossing, introduction, deployment (stents)/deflation (balloon catheter) and a \<30% residual stenosis on visual assessment of S.M.A.R.T. Flex Stent Iliac, S.M.A.R.T. Flex SFA/PP, S.M.A.R.T. Control Nitinol Stent, S.M.A.R.T. Nitinol Stent, PALMAZ Blue .018 Peripheral Stent on Slalom, PALMAZ Genesis .035 Peripheral Stent on Opta Pro, SABER OTW PTA Catheter, SABERX PTA Dilatation Catheter and PowerFlex Pro PTA Catheter according to the respective IFU.
Freedom from clinically-driven target lesion revascularization12 monthsPrimary Efficacy Endpoint: The primary efficacy endpoint is freedom from clinically-driven target lesion revascularization (CD-TLR) at 12 months, defined as any reintervention at the target lesion due to symptoms.

Secondary

MeasureTime frameDescription
Stent migration rateUp to 30 days post-procedure, 12-, 36- and 60-monthsStent migration rate assessed at up to 30 days post-procedure, 12-, 36- and 60-months.
Change of Ankle Brachial IndexUp to 30 days post-procedure, 12-, 36- and 60-monthsChange of Ankle Brachial Index (ABI) assessed at up to 30 days post-procedure, 12-, 36- and 60-months compared to baseline ABI.
Time-to-hemostasisDay of procedureTime-to-hemostasis assessed for the Cordis vascular closure devices (MynxGrip and Mynx Control). Categorized as Hemostatic time category (HTC) ≤2, HTC \>2 to ≤4, HTC \>4 to ≤5, HTC \>5 to ≤7, HTC \>7 to ≤10 min.
Time-to-ambulationDay of procedureTime-to-ambulation assessed for the Cordis vascular closure devices (MynxGrip and Mynx Control) defined as time between end of the procedure and ambulation in hours.
Technical success rateDuring the procedureTechnical success rate defined as successful crossing, introduction, deployment and successful completion of the procedure of the Cordis guidewires (Emerald, ATW, Stablizer, Storq, SV 0.018, Wizdom) and/or the Cordis guiding catheters (Adroit, Vista Brite Tip) and/or the Cordis diagnostic catheters (Super Torque, Super Torque MB, Super Torque Plus, Infiniti 4F/5F/6F, Tempo 4F, Tempo Aqua, High Flow, Pigtail Straightener) and/or the Cordis vascular access devices (Avanti+, Brite Tip, Vista Brite IG, vessel dilator) and/or the Cordis vascular closure devices (MynxGrip and Mynx Control) and/or the Cordis OUTBACK CTO catheters according to the respective IFU.
Clinical successUp to 30 days post-procedure, 12-, 36- and 60-monthsClinical success at up to 30 days post procedure, 12-, 36- and 60-months, defined as an improvement of the Rutherford Classification of one class or more, as compared to the pre-procedure Rutherford Classification.
Vessel perforation/dissectionDuring the procedureVessel perforation/dissection during the procedure.
Freedom from Serious Adverse Events (SAEs) and Serious Adverse Device Events (SADEs)36- and 60-monthsFreedom from Serious Adverse Events (SAEs) and Serious Adverse Device Events (SADEs) at 36- and 60-months after the procedure.
All cause of mortalityprocedure through study completion (12 months)All cause of mortality through life of the study.
Rate of Major Amputation free survivalUp to 30 days post-procedure, 12-, 36- and 60-monthsRate of Major Amputation free survival defined as any amputation above the knee assessed at up to 30 days post-procedure, 12-, 36- and 60-months.
Freedom from CD-TLR36- and 60-monthsFreedom from clinically-driven target lesion revascularization (CD-TLR) at 36- and 60-months, defined as any reintervention at the target lesion due to symptoms.
Stent fracture rateUp to 30 days post-procedure, 12-, 36- and 60-monthsStent fracture rate assessed at up to 30 days post-procedure, 12-, 36- and 60-months.

Countries

Austria, France, Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026