Skip to content

Postural Control in Covid-19

Covid 19 and Postural Sway: A Comprasion of SARS-CoV-2 and Healthy Sedentary Women

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05299320
Enrollment
56
Registered
2022-03-29
Start date
2022-03-02
Completion date
2022-06-20
Last updated
2022-07-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

COVID-19, Performance

Brief summary

This study was planned to investigate how much the anaerobic performance of individuals who experienced fatigue with Want (Wingate) affected their postural sway parameters.

Detailed description

The postural sway parameters of the individuals will be evaluated using the Kistler Force Plate and the anaerobic values will be evaluated using the Wingate Anaerobic Strength Test and the Excalibur Sport Ergometer device. The data obtained will be compared with the data of patients with and without Covid-19 disease using appropriate statistical methods.

Interventions

DIAGNOSTIC_TESTNeuromuscular fatigue and postural sway evaluation

Neuromuscular fatigue will be established by using the Excalibur Sport Ergometer device and the Wingate Anaerobic Strength Test. Postural sway will be evaluated with Cyst Force Plate Balance device. This device is a precision device that provides objective measurable data.

Sponsors

Karamanoğlu Mehmetbey University
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 30 Years
Healthy volunteers
Yes

Inclusion criteria

* Being between the ages of 18-30, - Being a volunteer - Having had Covid 19 in the last 3 month

Exclusion criteria

* Presence of neurologic and oncologic disease - Presence of orthopedic surgery - Presence of active Covid 19 disease - Any cardiopulmonary disease

Design outcomes

Primary

MeasureTime frameDescription
Postural Sway3 monthsPostural sway will be evaluated with Cyst Force Plate Balance device. This device is a precision device that provides objectively measurable data. Thanks to its movable platform, it can measure in all directions. Participants will be asked to stand on the platform assessing their body oscillations. They will be asked to look at a still picture on the wall with their arms at the iliac and eyes directly opposite them. Individuals will be asked to keep their designated positions for 30 seconds. At the end of the specified period, the data obtained from the device will be saved. Before and after the neuromuscular fatigue test postural sway will be evaluated.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026