Skip to content

Use of Superparamagnetic Iron Oxide (SPIO) in Sentinel Lymph Node Detection for Breast Cancer

Use of Superparamagnetic Iron Oxide (SPIO) Versus Conventional Radioisotope and Patent Blue Dye in Sentinel Lymph Node Detection for Breast Cancer: a Randomized Controlled Trial

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05288686
Enrollment
282
Registered
2022-03-21
Start date
2018-07-24
Completion date
2024-06-30
Last updated
2023-05-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast Cancer, Sentinel Lymph Node

Keywords

superparamagnetic iron oxide, sentinel lymph node detection rate

Brief summary

Sentinel lymph node biopsy is mandatory during breast cancer operation for disease staging and treatment. The localization of sentinel lymph node is by the injection of radioisotope and blue dye, which is the gold standard. However the use of radioisotope and blue dye are associated with specific drawbacks. Superparamagnetic iron oxide is a magnetic tracer which is FDA-approved for sentinel lymph node localization. The hypothesis of this study is superparamagnetic iron oxide can replace the conventional dual mapping of radioisotope and blue dye in the detection of sentinel lymph nodes for early breast cancers.

Detailed description

Sentinel lymph node biopsy has replaced axillary dissection as the standard of care in clinically node negative breast cancer. Lymphatic mapping with radioisotope and blue dye were most studied tracer agents and their combination was shown to give the highest nodal identification rate and lowest false negative rate. However the use of radioisotope is strictly monitored due to its radioactivity and blue dye is associated with potential allergic reactions and skin tattoo. Superparamagnetic iron oxide is non-radioactive. It gives an audible signal with the magnetometer and a brown color as visual cue. It has demonstrated comparable nodal identification rate with the conventional method in multiple non-inferiority trials in Europe and the USA. There was no randomized controlled trial for a head-to-head comparison between these mapping technique. The hypothesis of this study is superparamagnetic iron oxide alone can replace the conventional dual mapping of radioisotope and blue dye. Previous literature suggested the nodal detection rate for conventional method and SPIO was around 97%. Assuming a non-inferiorly limit of 5%, with a power of 80% and 5% significance level, the number of patients per treatment arm should be 144. We will need a sample size of 300 patients, taking into account a loss to follow-up of \<5%. All patients recruited will be provided full explanation of the study and written voluntary consents will be obtained before randomization. All data will be prospectively collected by dedicated research assistant and computerized into a database. All statistical analysis will be performed with Statistical Product and Service Solution (SPSS) version 24. Missing information will be marked and significant missing data will be excluded from analysis. Chi-square test will be used to compare discrete variables and student T test or Mann Whitney U test for continuous variables. P value less than 0.05 will be considered statistically significant. Personal data will be obtained by principal investigator and dedicated research assistant to allow analysis of the results. These data will be anonymous, only identified by the first three letters of patient's name. The file will be encrypted and stored in the study institution. All the information will be solely for research purpose and kept strictly confidential. Research subjects will be provided with phone contacts for any questions or emergency related to the study.

Interventions

PROCEDUREsentinel lymph node biopsy procedure

Patient received respective tracer injection and sentinel lymph node biopsy was performed in the operation theatre with the corresponding device.

Sponsors

The University of Hong Kong
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Masking description

Masking is not possible due to the different color of the injected tracer.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* All patients with clinical T1-3N0 invasive ductal carcinoma or invasive lobular carcinoma planned for breast conservative surgery or mastectomy, with sentinel lymph node biopsy * Patients planned for upfront operation or neoadjuvant chemotherapy are allowed

Exclusion criteria

* Patients with hypersensitivity to dextran compounds, iron or blue dye * Patients with iron overload disease * Pregnant or lactating patients * Patients with pacemaker or other implantable metallic devices in chest wall or prosthesis in shoulder * Mentally incompetent patients

Design outcomes

Primary

MeasureTime frameDescription
sentinel lymph node detection rate per patientAt the time of operationSuccessful sentinel lymph node localization for each arm

Secondary

MeasureTime frameDescription
Duration of skin stainpost-operative 3 month, 6 month, 12 month and 18 monthDuration of blue stain (from blue dye) and brown stain (from SPIO) in respective arm
Number of sentinel lymph nodes detectedAt the time of operationNumber of sentinel lymph nodes detected in each arm
Duration of sentinel lymph node biopsyDuration of the operation from incision of axillary fascia to satisfactory nodal basin countDuration of sentinel lymph node biopsy procedure in each arm
Detection rate of pathologically involved sentinel lymph nodesAt operationDetection rate of malignant sentinel lymph nodes in each arm

Countries

Hong Kong

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026