Comparative Study of Skin Prick Allergy Test Measurements Between Current Manual Procedure and Nexkin DSPT Device

Concordance Between the Electromedical Device Nexkin DSPT and the Manual Procedure in the Measurement of Papules in Allergy Skin Testing

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05284565
Enrollment
93
Registered
2022-03-17
Start date
2021-05-20
Completion date
2021-07-27
Last updated
2023-04-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Allergy

Keywords

skin prick test, allergy, skin testing, SPT, 3D imaging, allergy testing, allergy test reading, automatic measurement

Brief summary

Clinical trial with the aim to evaluate the level of agreement in wheal size measures in allergy skin prick testing (SPT) between the electro-medical device Nexkin DSPT® and the manual measurement procedure used in the daily practice.

Detailed description

The purpose of the trial is to evaluate the concordance of measurements obtained by the Nexkin DSPT device versus the measurements obtained manually. A prospective clinical trial study was conducted at Clínica Universidad de Navarra. SPT will be tested in the same way as during a routine visit, with the only difference being that the images of the arm required for the device to operate will be captured. Nexkin DSPT device is a non-invasive device, which does not perform the procedure of puncture and appearance of papules. The device is only used to read the test results. There is no risk to the patient or the healthcare professionals involved in capturing images with the device. Device does not provide a diagnosis and it is not a substitute for sound medical judgment. The study will prospectively include patients attending the allergy consultation (sample size calculated in 93 patients) with positive (histamine) and negative (saline solution) controls. Fifteen minutes later, two consecutive readings with the device and two manual readings were performed by two different nurses. The area of the histamine wheals was measured automatically by Nexkin DSPT and after the manual procedure measured manually by planimetry.

Interventions

DEVICEReading of the skin prick allergy test

A double reading of the forearm will be performed with the Nexkin DSPT device. Also, two healthcare professionals will perform, consecutively, the manual reading according to their usual practice. Nexkin DSPT device provides a semi-automatic wheal detection, presenting the user an initial set of potential wheals and information about them (as their measure). Healthcare professional can then discard, add and/or confirm wheals by visual validation, and add/edit wheal information. The device automates the test reading process, digitises the results, and quantifies.

Sponsors

Clinica Universidad de Navarra, Universidad de Navarra
CollaboratorOTHER
INNOPRICK SL
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

The study will prospectively include patients attending the Allergology Department, after signing an informed consent form and a data protection clause.

Eligibility

Sex/Gender
ALL
Age
12 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patient to be tested with aeroallergen and/or food battery prick tests. 2. Patient over 12 years of age. 3. Patient, or his/her representative, who has given consent to participate in the study. 4. Patient who has not taken an antihistamine for more than 3 days. 5. Women of childbearing age who, at the time of taking the clinical history, declare that they are not pregnant.

Exclusion criteria

1. Patients who are to be tested with a prick number greater than 40. 2. Patients who are to be tested with a prick number less than 40, but for whom it is necessary to place more than two rows of allergens in at least one of the arms. 3. Patients who have taken an antihistamine within the previous 3 days. 4. Patients who are being treated with antidepressants or other drugs with an antihistamine effect. 5. Patients who suffer severe atopic dermatitis affecting the forearms. 6. Patients with dermographism. 7. Patients who are to undergo intradermal testing. 8. Pregnant women or women suspected of pregnancy.

Design outcomes

Primary

MeasureTime frameDescription
Agreement in wheal size measures in allergy skin testing between the electro-medical device Nexkin DSPT and the manual measurement procedure5 minutesFifteen minutes after the punctures have been performed, a double reading of the forearm shall be taken with the device. The first reading will be stored for later analysis, and the second reading will be used afterwards. The healthcare professional will then perform the manual reading and generate the manual result sheet as is standard practice. The health professional visually examines the forearm and compares his observation with the identification presented by the device. The result of the identifications made by the device as well as the interactions of the healthcare professional on the screen shall be recorded on the device. Diameter measurements are measured in millimetres (mm) and area measurements are measured in square millimetres (mm2).

Secondary

MeasureTime frameDescription
Test-retest reliability of device reading.5 minutes15 minutes after the punctures have been performed, a double reading of the forearm shall be taken with the device. The first reading will be stored for later analysis, and the second reading will be used afterwards. The healthcare professional will then perform the manual reading and generate the manual result sheet as is standard practice. The health professional visually examines the forearm and compares his observation with the identification presented by the device. The result of the identifications made by the device as well as the interactions of the healthcare professional on the screen shall be recorded on the device. Diameter measurements are measured in millimetres (mm) and area measurements are measured in square millimetres (mm2).
Variability in measurements of histamine wheals made by different health professionals.5 minutes15 minutes after the punctures have been performed, a reading of the forearm will be performed by the device. Then, a first healthcare professional will perform the manual reading and generate the manual result sheet as in standard practice. Immediately afterwards, the first professional will erase the contours of the wheals on the forearm of the patient. A second healthcare professional will perform the manual reading without knowing the reading performed by the first one, and will generate the manual result sheet as is done in routine practice. The reading order of each test between the two healthcare professionals is randomised. Diameter measurements are measured in millimetres (mm) and area measurements are measured in square millimetres (mm2).

Countries

Spain

Outcome results

None listed