Skip to content

Comparing Arrow PICC Catheters w/ Arrowga+rd Blue Advanced Protection Performance and Safety to Unprotected PICC's

A Prospective, Randomized Study Comparing Device Performance Characteristics and Safety of Arrow Peripherally Inserted Central Catheters With Arrowga+rd Blue Advanced Protection to Standard Unprotected PICCs

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05278507
Enrollment
444
Registered
2022-03-14
Start date
2020-01-16
Completion date
2023-06-30
Last updated
2023-01-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Peripherally Inserted Central Catheter

Keywords

PICC

Brief summary

This study seeks to compare the standard unprotected PICC with the AGBA PICC for placement success, incidence of venous thrombosis through duplex ultrasound, observing for signs and symptoms of thrombotic occlusion and recording treatment response when diagnosed by sluggish fluid flow, inability to aspirate blood and or difficulty/inability to infuse via a lumen or lumens of the catheter. The incidence of catheter-related bloodstream infection will also be tracked during the study.

Detailed description

The primary purpose of this study is to prospectively collect outcome data in order to evaluate the performance and safety of the Arrowga+rd Blue Advanced PICC with regard to first attempt insertion success and incidence of complications as compared to use of standard, unprotected PICC devices. Patients will receive peripherally-inserted central catheters that are indicated for short or long term peripheral access to the central venous system for intravenous therapy, blood sampling, infusion, pressure injection of contrast media and allows for central venous pressure monitoring. Using randomization, patients will be assigned to receive the institution's standard of care uncoated/unprotected PICC or the study device, the Arrow PICC with Arrowga+rd Blue Advanced Protection Study Device: Arrow PICC With Arrowga+rd Blue Advanced Protection: The Arrow PICC with Arrowga+rd Blue Advanced protection (Teleflex Medical Incorporated, Morrisville, NC, USA; hereafter referred to as AGBA) is an FDA-cleared pressure injectable device that offers both antimicrobial and anti-thrombogenic protection for at least 30 days. The application of Arrowga+rd Blue Advanced protection uses a proprietary process whereby chlorhexidine is chemically bonded to the intra- luminal catheter surfaces from tip to hub, and extra-luminal catheter body. The device is cleared for marketing in the United States of America by the Food and Drug Administration, and has obtained the CE mark for marketing in the European Union. The French size and length selected for use will be documented. Standard of Care: The standard, unprotected PICC currently in use at the institution will be used in this study (here after referred to as Standard). The details of the PICC selected will be recorded including brand, French size, and length. Study Design: Prospective, randomized, multicenter study Number of Subjects: 444 subjects will be enrolled in the study and randomized to receive one of the two PICC devices. Duration of Subject Study Participation: Maximum of 92 days, which includes a maximum dwell time of 90 days and follow up 1 to 2 days - 9 days post PICC removal. A subject may remain in the study, with the CVC in place, beyond the expected maximum participant duration (90 days dwell, 1 - 2 day posts removal follow up) if the following conditions are met: * On day 90 dwell, the subject requires continued PICC access, the assigned PICC remains functional, and it is in the best interest of the subject to continue access via the inserted device. * It is in the best interest of the subject for the PICC to remain in place, due to health concerns precluding device removal.

Interventions

DEVICEArrowga+rd Blue Advance Protection PICC Placement

The PICC will be placed by a qualified healthcare professional, in accordance with institutional policies and procedures and the device's IFU.

DEVICESham Comparator PICC placement

The sham comparator PICC will be placed by a qualified healthcare professional, in accordance with institutional policies and procedures and the device's IFU.

Sponsors

Teleflex
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Intervention model description

The primary purpose of this study is to prospectively collect outcome data in order to evaluate the performance and safety of the Arrowga+rd Blue Advanced PICC with regard to first attempt insertion success and incidence of complications as compared to use of standard, unprotected PICC devices.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients age ≥ 18 years requiring a PICC * Patient will remain an inpatient for the entire dwell time * Ability to comply with study requirements of duplex ultrasound procedures prior to and at the time of PICC removal * Patients cognitively and physically able to give written consent to participate in the study or patient has a legally authorized representative (LAR) who may give written consent to participate in the study

Exclusion criteria

* Current diagnosis of venous thrombosis within the venous tract of the proposed catheter * Diagnosis of peripheral or central vein stenosis (on proposed insertion side) * History or diagnosis of veno-occlusive disease * Diagnosis of superior vena cava syndrome * Known, pre-existing diagnosis of hypercoagulation disorder unrelated to underlying disease * Previous enrollment in this study * Currently pregnant or breast feeding * Skin condition at or within 15 cm of the proposed catheter insertion site, including signs and symptoms of inflammation, rash, crusts, wounds with drainage, sites of intravenous infusion infiltration or extravasation, hematoma, phlebitis and or thrombophlebitis * Medical, social, and/or psychological problems precluding subject from study participation * Known allergy or sensitivity to chlorhexidine

Design outcomes

Primary

MeasureTime frameDescription
Incidence of catheter related bloodstream infection assessed by laboratory confirmed bloodstream infectionup to 92 daysSubjects will be assessed for laboratory confirmed bloodstream infection (LCBI) as described below through one day post PICC removal LCBI 1 Patient of any age has a recognized pathogen, which is an organism not included on the NHSN common commensal list, identified from one or more blood specimens obtained by a culture or non-culture based microbiologic testing method (excluding organisms identified by testing on sera) AND Organism(s) identified in blood is not related to an infection at another site LCBI 2 Patient of any age has at least one of the following signs or symptoms: fever (\>38.0oC), chills, or hypotension AND Organism(s) identified in blood is not related to an infection at another site AND The same NHSN common commensal is identified by a culture or non-culture based microbiologic testing method, from two or more blood specimens collected on separate occasions.
First attempt PICC insertion successDuring placementrate of first attempt insertion success = number of patients with first attempt insertion /total number of patients \*100% • First attempt insertion success and number of failed attempts will be documented
PICC Placement Success - Confirmation of tip placement in the lower 1/3 of the superior vena cava at or above the superior vena cava/right atrium junction will be performed by chest x-ray or other tip confirmation system/device and documented.During placementOnce the PICC placement is complete, confirmation of catheter tip location in the lower 1/3 of the superior vena cava at or above the superior vena cava/right atrium junction will be performed by chest x-ray or other tip confirmation system/device and documented. Any adjustments to catheter length post-insertion must be performed using sterile technique and maximal barrier precautions. The number of adjustments to the inserted PICC needed to achieve proper tip location will be recorded.
Confirmation of tip patency by aspirating each lumen for brisk blood return and flushing each lumen with at least 10 mL of 0.9% NaCl injection USPup to 92 daysOnce the PICC placement is complete, the inserter will confirm patency by aspirating each lumen for brisk blood return and flushing each lumen with at least 10 mL of 0.9% NaCl injection USP. For inpatients, each lumen will be assessed for patency at least every 12 hours and/or before administration of infusion therapies. Patency assessments will be documented. * Patency checks resulting in brisk blood return and ability to flush easily will be considered patent. * Patency checks resulting in inability to aspirate blood with ability to flush easily will be documented as a withdrawal occlusion. * Patency checks resulting in sluggish flow and/or ability to flush will be documented as a partial occlusion. * Patency checks resulting in inability to aspirate blood and inability to flush will be documented as a complete occlusion.

Secondary

MeasureTime frameDescription
Incidence of complete loss of catheter function versus the total number of effective catheters placedup to 92 daysIncidence of total loss of catheter function = number of total loss of catheter function/number of effective catheter placement
Incidence of catheter-associated external wall thrombosis versus the total number of effective catheters placedup to 92 daysIncidence of catheter-related external wall thrombosis = number of patients with catheter-related external wall thrombosis/total number of patients with effective catheter placement
Device performance evaluationDuring placementEvaluate whether the accessories in the package meet the control requirements of the country and the medical institution, whether the guide wire placement is smooth, whether the catheter placement is smooth, and whether the product is smooth and satisfactory
Evaluation of other safety parameters such as Adverse Events and Device Defects during testingup to 92 days1. Vital signs (temperature (C), heart rate (b.p.m.), respiration rate (b.p.m.) and blood pressure (m.m.Hg) throughout the clinical study period); 2. Laboratory examination (as appropriate during the evaluation process); 3. The number and incidence of any related adverse events, severe adverse events during the trial 4. Number and incidence of any device defects during the test

Countries

China

Contacts

Primary ContactLinda Wu
lindi.wu@teleflex.com15010697631
Backup ContactJovan Xu
Jovan.Xu@teleflex.com86106411

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026