Sensing Oxygen Saturations Using Abdominal NIRS With an Investigational Realtime Device (Songbird)

An Open Single-center Study in England to Assess Safety and Performance of a NIRS System to Monitor Abdominal Tissue Oxygen Saturation in Preterm Infants

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05278247
Acronym
(Songbird)
Enrollment
50
Registered
2022-03-14
Start date
2026-02-01
Completion date
2027-12-31
Last updated
2025-11-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

NEC

Keywords

abdominal NIRS for oxygen saturation

Brief summary

Preterm infants are highly vulnerable and may suffer from multiple life-threatening conditions that manifest low tissue oxygenation (StO2). Near infrared spectroscopy (NIRS) is a technique available to non-invasively and safely monitor the tissue oxygenation status (StO2), which can be beneficial or live saving for this fragile patient population. Unfortunately, traditional NIRS devices show a broad variability when applied to the abdomen (Bailey & Mally 2016). The novel device is designed especially for application of NIRS on the abdomen of preterm infants.

Detailed description

Each child will be measured over a time span of three days with the novel NIRS device. 1. A two-hour measurement is performed in measurement phase 1 2. Additionally, the sensor will be placed five times onto the abdomen for 1-minute measurements, which constitutes measurement phase 2. 3. The final measurement phase 3 lasts for up to 70 hours. A total of two ultrasound (US) examination on the abdomen are performed during the first two measurement phases to assess the presence of air and stool in the abdomen. Additional assessment of SpO2 is performed throughout. Aside from the US and SpO2 measurement, no additional procedures will be performed. The NIRS measurement will not disturb necessary clinical and nursing procedures.

Interventions

DIAGNOSTIC_TESTNIRS

Performance of a NIRS to monitor abdominal tissue oxygen saturation in preterm infants

Sponsors

Carag AG
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
BASIC_SCIENCE
Masking
NONE

Intervention model description

confirmatory, open, single-arm, mono-centric

Eligibility

Sex/Gender
ALL
Age
1 Days to 7 Days
Healthy volunteers
No

Inclusion criteria

1. Preterm infants with Gestational age less than 35 0/7 weeks 2. Signed Informed consent of the legal representative(s) is received after being informed. The consent form is signed by one legal representative, which is likely to be either the mother or the father. Only married fathers or those listed on the birth certificate are considered under UK regulations. In the case of non-married father, the mother must provide consent. 3. Clinically stable condition. The clinical stability is to be reconfirmed before the start and checked during the measurement.

Exclusion criteria

1. Injured, hypersensitive or bruised skin present on the abdomen, 2. Existence of clinical instability at any time during the investigation leads to exclusion, if ordered so by the physician entrusted with the investigation, 3. Any medical care equipment, e.g. patches, dressing, umbilical arterial or venous catheter, blood supply, etc., prohibiting correct placement of the sensors, 4. Severe Congenital malformations, 5. Clinical abdominal concerns 6. Severe metabolic disorders, 7. Early onset sepsis, 8. Inability of legal representatives to understand the purpose of the clinical trial due to language barriers such as the insufficient ability to understand the spoken or written language, 9. The treatment of newborn jaundice with light during measurement time phase 1 and 2, 10. Previous enrolment into the current study, 11. Family members, employees and other dependent persons of the investigator, 12. Participation in another study with investigational drug/device within the preceding days and during the present study which may influence abdominal oxygen saturation. 13. Known silicone allergy

Design outcomes

Primary

MeasureTime frameDescription
Performance of the CTOM system3 daysWe intend to investigate sensor handling on preterm infants and record the signal variability and reproducibility. A measurement signal serves to analyse reproducibility, signal quality and different signal analysis methods. Abdominal oxygen tissue saturation will be calculated. The aStO2 values will be calculated with and without considering the presence of additional absorbers besides haemoglobin. The datasets to be analysed include three measurement series per subject from a total of at least 50 subjects. The planned analyses consist of descriptive statistics and time series analysis.

Secondary

MeasureTime frameDescription
Occurrence of adverse events is measured3 daysAEs will be recorded and analyzed with regards to their relationship to the investigational device and the measurement procedure. The occurrence of adverse events, especially skin markers, will be measured. The study will compare AEs and SAEs from this study with documented AEs and SAEs employing NIRS devices.