Skip to content

Effect of Novel Exhalational Delivery System With Fluticasone (EDS-FLU) on Eustachian Tube Dysfunction (ETD)

Effect of Novel Exhalational Delivery System With Fluticasone (EDS-FLU) on Eustachian Tube Dysfunction (ETD) in a Multi-center, Double-Blinded, Placebo-controlled Trial

Status
Recruiting
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05275686
Enrollment
80
Registered
2022-03-11
Start date
2022-04-20
Completion date
2027-12-31
Last updated
2026-03-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Eustachian Tube Dysfunction

Keywords

Eustachian Tube Dysfunction, Fluticasone

Brief summary

Intranasal nasal steroid sprays are the mainstay of treatment for chronic Eustachian tube dysfunction despite having little supportive evidence in the literature. A novel, commercially available nasal spray delivery system is available now for fluticasone that improves its delivery to the nasopharynx. The hypothesis of this study is that fluticasone using the novel spray system is effective for Eustachian tube dysfunction (ETD).

Detailed description

BACKGROUND AND RATIONALE Eustachian tube dysfunction (ETD) can be a symptom of allergic rhinitis, non-allergic rhinitis, or chronic rhinosinusitis. However, it can also be a separate entity with patients displaying no other symptoms of the previously mentioned diseases. There is currently no FDA- approved medication specifically for eustachian tube dysfunction, but most otolaryngologists, allergists, and primary care physicians employ multiple different over-the-counter and prescription medications for its treatment. Most common are oral and topical antihistamines, nasal steroid sprays, topical and oral decongestants, and oral steroids. Nasal steroid sprays, which are FDA-approved for allergic rhinitis, are most frequently used for chronic ETD despite a lack of large clinical trials to support their use. These sprays do have good safety profiles, are frequently available over-the-counter, and do have good data on their efficacy in rhinitis and sinusitis. Fluticasone nasal spray is available over the counter and is a nasal steroid spray. It is frequently recommended or prescribed for chronic eustachian tube dysfunction. However, its efficacy and the efficacy of all nasal sprays may be limited by the access of previously available sprays into the nasopharynx. The level of evidence for these sprays in chronic ETD is poor overall with only one randomized controlled trial in adults. This study determined no benefit over placebo. In studies determining the deposition of nasal sprays, most of the spray is deposited in the front of the nasal cavity over the inferior turbinates and very little gets into the sinus cavities or nasopharynx. A new exhalational delivery system fluticasone spray (EDS-FLU) has been FDA-approved for patients with chronic rhinosinusitis with polyps. The main difference between this spray and previously available sprays is that it penetrates deeper into the sinuses and also to the nasopharynx, the location of the eustachian tubes. In this system, the user blows out while pumping the spray bottle and his/her breath is the driving force of the spray bottle. Blowing out also elevates the soft palate, seals the nasopharynx, and contains all the spray into the nasal cavity, sinuses, and nasopharynx. In a traditional spray, the soft palate is at resting position, and the spray can pass through the nasal cavity and down into the oropharynx and mouth. This is typically perceived by many users as postnasal drip after the use of nasal sprays. The investigators have previously published a retrospective review of the use of EDS-FLU in patients with at least 1 month of ETD symptoms and found that 79% had improvement more than the minimal clinically important difference. Thirty-six percent of patients normalized with regards to symptoms, and 80% of patients with pre- and post-treatment tympanometry normalized their tympanogram. This study will compare placebo to fluticasone exhalational nasal spray system (Xhance) in a randomized, controlled study.

Interventions

DRUGFluticasone Propionate 93 MCG/1 ACTUATION Nasal Spray

Patients will use two sprays in each nostril twice a day for 6 weeks and additional 6 weeks (open label).

OTHERPlacebo Nasal Spray

The Placebo is made of the following ingredients: Purified Water, Microcrystalline Cellulose RC-591, Dextrose, Anhydrous, EDTA Disodium Dihydrate, Benzalkonium Chloride Solution 50%, Polysorbate 80 (Tween 80, HP-LQ-(MH)), Sodium Hydroxide, and Hydrochloric Acid. Patients will use two sprays in each nostril twice a day

Sponsors

Cedars-Sinai Medical Center
Lead SponsorOTHER
Sacramento Ear, Nose & Throat
CollaboratorUNKNOWN
Ochsner Health System
CollaboratorOTHER
Indiana University
CollaboratorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Caregiver, Investigator)

Masking description

Patients and investigators will be kept blinded until the end of the study.

Intervention model description

* Group 1 will get the EDS-FLU nasal spray and use at its normal twice a day dosing. * Group 2 will get the placebo nasal spray in an identical spray canister and use it twice a day. Patients will be randomized to receive placebo in the novel exhalation delivery system versus fluticasone in the device. Patients will take the spray twice daily for six weeks and then return for evaluation. An open label extension will be planned for both groups (placebo, non-placebo) at the end of the six weeks to use the EDS-FLU for an additional six weeks.

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* Age greater than or equal to 18 years old, \<80 years old * Chronic Eustachian tube dysfunction defined as: * Symptoms in one or both ears \> 3 months AND * ETDQ-7 score \>14.5 AND * Type B, C, or As tympanometry * Female subjects of childbearing potential must have a negative urine pregnancy test at screening and throughout the study duration.

Exclusion criteria

* Age \<18 years old * Known history of otologic surgery (excluding myringotomy or myringotomy tubes) * Use of any additional intranasal medication * Tympanic membrane perforation * Adhesive otitis media * Cholesteatoma or significant retraction pocket * Middle ear effusion * Nasopharyngeal tumor * Any history of head and neck cancer * Any history of head and neck irradiation * Any history of temporomandibular disorder or prior surgery to the temporomandibular joint * Any medical condition that the investigator deems inappropriate for enrollment

Design outcomes

Primary

MeasureTime frameDescription
7-Item Eustachian Tube Dysfunction Questionnaire (ETDQ-7)visit 2 (week 6)Eustachian tube dysfunction symptoms measured by the validated quality of life 7-Item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) at visit 2. The scale is from 1 (no problem) to 7 (severe problem).

Countries

United States

Contacts

CONTACTMissael Vasquez
missael.vasquez@cshs.org424-315-2437
CONTACTLaura Sarmiento, CCRP
laura.sarmiento@cshs.org3104234295
PRINCIPAL_INVESTIGATORArthur Wu, MD

Cedars-Sinai Medical Center

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 12, 2026