Skip to content

Correlation Between New O3 Regional Oximetry, Electroencephalography and the Somatosensory Evoked Potential in Carotid Endarterectomy Surgery

Correlation Between New O3 Regional Oximetry, Electroencephalography and the Somatosensory Evoked Potential in Carotid Endarterectomy Surgery

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05267782
Enrollment
10
Registered
2022-03-04
Start date
2022-04-01
Completion date
2025-03-31
Last updated
2024-02-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Carotid Endarterectomy

Keywords

O3 regional oximetry, somatosensory evoked potential, electroencephalography, carotid endarterectomy surgery

Brief summary

Carotid endarterectomy (CEA) is one of the modalities to treat carotid artery disease. One of the perioperative complications of this surgery includes stroke, a condition that occurs when the blood supply to part of your brain is interrupted or reduced. To prevent cerebral ischemia during carotid endarterectomy several methods have been employed in clinical practice, such as awake neurocognitive assessment, electroencephalography, evoked potentials, transcranial Doppler, carotid stump pressure, and near infrared spectroscopy (Regional Oximetry). Meta-analysis published by Nwachuku EL and colleagues suggests that intraoperative somatosensory evoked potential (SSEP) is a highly specific test in predicting neurological outcome following CEA. Sridharan and colleagues advise multimodality in intraoperative monitoring, with simultaneous use of EEG and SSEP which will improve the diagnostic accuracy. Use of regional oximetry as a continuous, real time and non-invasive monitoring, during CEA is controversial, with pros and cons studies that do not contribute to a clear picture of its application in everyday clinical practice. Masimo's O3 Regional Oximetry is new monitoring approved in 2020 by FDA for monitoring somatic tissue oxygenation saturation in all patient populations and for monitoring relative changes in haemoglobin, oxyhaemoglobin, and deoxyhaemoglobin in adult brains. This monitoring can help clinicians to monitor cerebral oxygenation in situations in which pulse oximetry alone may not be fully indicative of the oxygen in the brain. One such example is carotid endarterectomy (CEA). Masimo's O3 regional oximetry is integrated part of the SedLine® Brain Function Monitoring (Masimo, Irvine, California, USA, 1989) on the Root® Patient Monitoring Platform. Sensors are equipped within Masimo Open Connect (MOC-9) modules which are applied to the patient's forehead and connected to the Masimo Root® patient monitoring and connectivity platform. Masimo's O3 Regional Oximetry provides regional or tissue haemoglobin oxygen saturation and unlike peripheral pulse oximetry, which reflects the body's general arterial blood oxygenation, O3 provides information about the local tissue's haemoglobin oxygen saturation, both in cerebral and somatic applications. This information provides additional insight that may help inform clinicians of changes in cerebral or somatic tissue oxygen levels. Regional Oximetry is already part of the standard monitoring used during CEA in Cleveland Clinic Abu Dhabi, together with electroencephalography and the somatosensory evoked potentials. Using new Masimo's O3 regional oximetry monitoring (same sensor, only the module is new with new parameters) we will have additional parameters that have not been analysed before: * Δbase * ΔSpO2 * ΔcHbi * Δ HHbi * ΔO2Hbi With this in mind, the authors would like to analyse the correlation between new Masimo's O3 regional oximetry parameters, EEG and SSEP in CEA.

Interventions

DEVICEMasimo's O3 Regional Oximetry

Correlation between new O3 regional oximetry monitoring, electroencephalography and somatosensory evoked potential in carotid endarterectomy and data collection during different stages of anaesthesia and correlation with new O3 regional oximetry

Sponsors

Cleveland Clinic Abu Dhabi
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Subjects older than 18 years of age 2. Subjects undergoing carotid endarterectomy. 3. American Society of Anaesthesiologists Classification (ASA) score I to III.

Exclusion criteria

1. American Society of Anaesthesiologists Classification (ASA) score IV and V. 2. Subject has skin abnormalities affecting the sensor placement 3. Emergency cases 4. Cognitive/Mentally impaired or unable to provide consent 5. Pregnant subject

Design outcomes

Primary

MeasureTime frame
Correlation between new O3 regional oximetry monitoring, electroencephalography and SSEP in CEA.The anticipated duration will not exceed duration of surgery.

Secondary

MeasureTime frame
Data collection during different stages of anaesthesia and correlation with new O3 regional oximetryThe anticipated duration will not exceed duration of surgery.

Countries

United Arab Emirates

Contacts

Primary ContactBoris Tufegdzic, MD
tufegdb@clevelandclinicabudhabi.ae+971 2 659 0200
Backup ContactFrancisco Lobo, MD
LoboF@ClevelandClinicAbuDhabi.ae

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026