Skip to content

Is This PJI Really Acute: A Quantitative Sonication Fluid Analysis (Sonic)

Is This PJI Really Acute: A Quantitative Sonication Fluid Analysis

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05265598
Acronym
Sonic
Enrollment
176
Registered
2022-03-03
Start date
2021-06-30
Completion date
2024-08-31
Last updated
2025-01-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Prosthetic-joint Infection

Keywords

debridement, antibiotics and implant retention (DAIR), sonication fluid analysis

Brief summary

This retrospective study is to analyse microbiological cultures from the sonication fluid of the explanted prothesis to detect bacteria in the biofilm on the implant surface and to investigate whether the number of bacteria in the biofilm correlates with the duration of the PJI respectively with the period between symptom onset and date of revision surgery.

Detailed description

Implant associated infections in orthopaedics and trauma surgery are a well-known and feared complication. Prosthetic-joint infection (PJI) is caused by a biofilm which is located atop the surface of the implant which as growing with the duration of the PJI. This retrospective study is to analyse microbiological cultures from the sonication fluid of the explanted prothesis to detect bacteria in the biofilm on the implant surface and to investigate whether the number of bacteria in the biofilm correlates with the duration of the PJI respectively with the period between symptom onset and date of revision surgery.

Interventions

None listed

Sponsors

University Hospital, Basel, Switzerland
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* patients who underwent a revision surgery of hip, knee and shoulder arthroplasties operated at the university hospital of Basel between 2011 and 2021, * patients who had a PJI as a suspected diagnosis and * have microbiological cultures from sonication fluid from removed prosthesis.

Exclusion criteria

* patients in the database who 1. have non-bacterial microbiological positive cultures (e.g. fungal infection) and 2. have not received a sonication of the removed prosthesis during the diagnostic process

Design outcomes

Primary

MeasureTime frameDescription
number of bacteriaone time assessment at baselinenumber of bacteria detected during revision surgery will be taken from the sonication fluid and the quantitative analysis of the microbiological samples
duration of the infectionone time assessment at baselineduration of the infection

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026