Post Marketing Clinical Follow Up Study to Evaluate Efficacy and Safety of the Occlutech PDA Occluder in Patients With Patent Ductus Arteriosus Defects

A Multicenter, International, Prospective, Retrospective, Post Marketing Clinical Follow Up Study to Evaluate the Efficacy and Safety of the Occlutech Patent Ductus Arteriosus Occluder (PDA Occluder) in Patients With Patent Ductus Arteriosus Defects

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05264753
Enrollment
255
Registered
2022-03-03
Start date
2021-12-20
Completion date
2029-11-25
Last updated
2026-08-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Patent Ductus Arteriosus

Keywords

Occlutech PDA Occluder, Patent ductus arteriosus closure, Transcatheter PDA occlusion, Percutaneous catheter-based intervention, Occluder device, Post-marketing clinical follow-up, PMCF, Prospective and retrospective study, Multicenter international study, Efficacy and safety, Echocardiography follow-up, Pediatric cardiology

Brief summary

This retrospective and prospective, multicenter, international post marketing follow up study evaluates the safety and efficacy of the Occlutech® PDA Occluder, delivered using the Occlutech Occlusions Pusher (OOP), in subjects with patent ductus arteriosus (PDA) defects. Safety and efficacy assessments include vital signs, electrocardiograms, and echocardiographic evaluations performed at baseline/implantation (including assessments within 36 hours post procedure), as well as at follow up visits occurring between Day 30 and Day 90, 6 months to 1 year, 1 to 2 years, and 2 to 3 years after implantation.

Detailed description

The Occlutech® PDA Occluder is an occlusion system designed for the percutaneous, catheter based, non surgical closure of Patent Ductus Arteriosus (PDA), and is delivered using the Occlutech Occlusions Pusher (OOP) and Occlutech Delivery Set (ODS), which are recommended as compatible delivery systems. This post marketing clinical follow up study aims to evaluate the safety and efficacy of the Occlutech® PDA Occluder in subjects with PDA. The study is designed as a retrospective and prospective, multicenter, international investigation in which safety and efficacy will be assessed through vital signs, electrocardiography, and echocardiography at baseline/implantation (including assessments performed within 36 hours post procedure), followed by evaluations at Day 30 to Day 90, 6 months to 1 year, 1 to 2 years, and 2 to 3 years after implantation. A total of 217 evaluable subjects is required to estimate a proportion of ≤10% (or ≥90%) with a precision of 4% at an alpha level of 5%, corresponding to a two sided 95% confidence interval width of ≤8%. To account for an anticipated maximum drop out rate of 15%, a total of 255 subjects will be enrolled. Approximately 90% of enrolled participants are expected to be children aged 0-10 years. The primary objective of this study is to assess the safety of the Occlutech® PDA Occluder in subjects requiring transcatheter PDA closure, while the secondary objective is to evaluate the device's efficacy in achieving successful occlusion of the PDA

Interventions

DEVICEOcclutech® PDA Occluder

Non-surgical occlusion of Patent Ductus Arteriosus (PDA).

Sponsors

Occlutech International AB
Lead SponsorINDUSTRY

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* A subject of any age will be eligible for PDA closure if he or she meets the indication and area of application as laid down in the IFU. Including subjects more than 3 kg. Thus, the Occlutech PDA Occluder is intended for the non-surgical occlusion of Patent Ductus Arteriosus (PDA) defects. * Male or female subjects. * Subjects or their parents/guardians understanding the nature of the study and providing their informed consent to participation. * Subjects willing and able to attend the follow-up visits and procedures foreseen by study CIP.

Exclusion criteria

Contraindications as laid down in the IFU: * Silent ductus or serious pulmonary hypertension: * Pulmonary Vascular Resistance (PVR) \> 8 Wood Units * Presence of a known coagulation disorder * Thrombus at the position allocated for the implantation * A vein thrombosis in the blood vessels chosen for the introducing system * An active infection (active endocarditis or other infections causing bacteremia) or history of endocarditis within 3 months from the procedure. * Nitinol intolerance (nickel or titanium) * Contrast medium intolerance * Subjects who have a vascular system (which is used to access the defect) that is too small to admit the required sheath

Design outcomes

Primary

MeasureTime frameDescription
Safety primary endpoint1 yearThe primary safety endpoint is defined as the incidence of any Serious Adverse Device Effects (SADEs) including procedure-related death, procedure-related stroke, systemic embolism, severe hemolysis, device embolization, cardiac tamponade, infective endocarditis, or vascular complications requiring surgery up to 1-year post-implantation.
Efficacy primary endpoint2 yearsThe primary efficacy endpoint is defined as successful implantation of the Occlutech® PDA Occluder with a complete closure of the PDA (defined as \>90% PDA closure represented by no or small residual flow) as assessed by echocardiography post-implantation) within 2-year post- implantation follow-up.

Secondary

MeasureTime frameDescription
Safety secondary endpoint3 yearsSecondary safety endpoints will assess all minor complications such as transient hemolysis, vascular complications not requiring surgery, or all minor complications which are deemed relevant at the discretion of each investigator. Additionally, an assessment of all Serious Adverse Events (SAE) will be included in the analyses.
Efficacy secondary endpoint3 yearsSecondary efficacy assessments refer to the variation in the data from baseline to 3 years after the procedure in parameters such as, but not limited to, aortic blood pressure, pulse rate, LVFS, pulmonary artery pressure, and ECG records.

Countries

Canada, France, Italy, Pakistan, Sweden, Switzerland, Tunisia, Turkey (Türkiye), United Kingdom

Contacts

CONTACTAhmed Dellaa, PhD
ahmed.dellaa@occlutech.com+49 3641 508 367
CONTACTGonul Sonmez Utkun
gonul.sonmezutkun@occlutech.com+90 212 465 04 97

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 13, 2026