Influence of Different Toric Intraocular Lenses on IOL-capsular Complex

Influence of Different Toric Intraocular Lenses on IOL-capsular Complex After Cataract Surgery

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05263518
Enrollment
100
Registered
2022-03-02
Start date
2022-05-01
Completion date
2022-12-01
Last updated
2022-04-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract, Corneal Astigmatism

Keywords

Various Types of toric IOLs

Brief summary

Corneal astigmatism is refractive error that impairs uncorrected visual acuity. When patients undergo cataract surgery, implantation of toric IOL is deemed the most effective choice for correcting corneal astigmatism and reducing postoperative spectacle dependence. The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant because of poor post-surgery visual quality especially for optical sophisticated IOLs such as toric IOLs. IOL instability could decrease the curative effect of toric IOL. There are numerous types of toric IOLs; however, AcrySof IQ and TECNIS toric IOL are most frequently used in the Ophthalmology Hospital of Wenzhou Medical University. AcrySof IQ IOL has some differences compared with TECNIS toric IOL. IQ has a modified L haptic design while TECNIS® toric IOL has a modified C haptic design. AcrySof IQ IOL has a discontinuous 360˚ posterior square edge while TECNIS toric IOL has a continuous 360˚ posterior square edge. The AcrySof IQ IOL cylinder power models include 1.00, 1.50, 2.25, 3.00, 3.75, 4.50, 5.25 and 6.00 D. The Tecnis IOL cylinder power models include 1.00, 1.50, 2.25, 3.00 and 4.00 D. Previous study pointed that patients with cataracts with corneal astigmatism achieved comparable improvement in visual acuity, astigmatism correction, CS(sensitive contrast), rotational stability and satisfaction, following AcrySof and TECNIS toric IOL implantation. However,some other studies found that the Acrysof toric IOL showed significantly greater rotational stability than the Tecnis toric IOL and the rate of surgical IOL repositioning was higher in eyes implanted with TECNIS than with AcrySof toric IOLs for astigmatic correction. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of toric IOLs implantation in patients using CASIA2. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can accurately evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.

Detailed description

Corneal astigmatism is refractive error that impairs uncorrected visual acuity. When patients undergo cataract surgery, implantation of toric IOL is deemed the most effective choice for correcting corneal astigmatism and reducing postoperative spectacle dependence. The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. Although up to 2-3 degree tilt and a 0.2-0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant because of poor post-surgery visual quality especially for optical sophisticated IOLs such as toric IOLs. IOL instability could decrease the curative effect of toric IOL. There are numerous types of toric IOLs; however, AcrySof IQ and TECNIS toric IOL are most frequently used in the Ophthalmology Hospital of Wenzhou Medical University. AcrySof IQ IOL has some differences compared with TECNIS toric IOL. IQ has a modified L haptic design while TECNIS® toric IOL has a modified C haptic design. AcrySof IQ IOL has a discontinuous 360˚ posterior square edge while TECNIS toric IOL has a continuous 360˚ posterior square edge. The AcrySof IQ IOL cylinder power models include 1.00, 1.50, 2.25, 3.00, 3.75, 4.50, 5.25 and 6.00 D. The Tecnis IOL cylinder power models include 1.00, 1.50, 2.25, 3.00 and 4.00 D. Previous study pointed that patients with cataracts with corneal astigmatism achieved comparable improvement in visual acuity, astigmatism correction, CS(sensitive contrast), rotational stability and satisfaction, following AcrySof and TECNIS toric IOL implantation. However,some other studies found that the Acrysof toric IOL showed significantly greater rotational stability than the Tecnis toric IOL and the rate of surgical IOL repositioning was higher in eyes implanted with TECNIS than with AcrySof toric IOLs for astigmatic correction. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of toric IOLs implantation in patients using CASIA2. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can accurately evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.

Interventions

PROCEDURECataract surgery with AcrySof IQ IOL implantation.

Patients in this study will receive cataract surgery with AcrySof IQ IOL implantation.

PROCEDURECataract surgery with TECNIS toric IOL implantation.

Patients in this study will receive cataract surgery with TECNIS toric IOL implantation.

Sponsors

Wenzhou Medical University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
50 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* The patients are diagnosed age related cataract or complicated with corneal astigmatism * The patients' age over 50 years old * The patients plan to receive cataract surgery in Eye hospital of Wenzhou Medical University * The dilated pupils are over 7mm * Patients are willing and able to complete the follow-ups.

Exclusion criteria

* Patients with other type of cataract * Patients have complications in the surgery and after surgery * Patients have other severe diseases of eyes

Design outcomes

Primary

MeasureTime frameDescription
The position of IOLThe 1st day after surgeryEvaluation of the position of IOL through tilt, decentration,rotation and the process of capsule bending using CAISA2(The novel anterior segment optical coherence tomography (AS-OCT) device)