Comparison of a Novel Non-diffractive Extended Depth of Focus Intraocular Lens (IOL) and a Trifocal IOL

Comparison of Visual Performance and Quality of Life With a Novel Non-diffractive Extended Depth-of-focus IOL and a Trifocal IOL

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05262504
Enrollment
52
Registered
2022-03-02
Start date
2021-04-01
Completion date
2021-09-01
Last updated
2023-07-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intraocular Lens, Cataract, Quality of Life

Keywords

cataract, wavefront shaping, extended depth of focus, trifocal, intraocular lens, quality of life, defocus curve, contrast sensitivity, photic disturbance

Brief summary

The purpose of this study is to compare visual performance and quality of life (QOL) following bilateral implantation of a novel non-diffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof® IQ Vivity, Alcon, TX, USA) and a trifocal IOL (Acrysof® IQ PanOptix, Alcon, Fort Worth, TX) in a prospective comparative interventional case series.

Detailed description

Developments in cataract surgical devices and intraocular lenses (IOL) increased patient expectations and changed the practice patterns in ophthalmology. Nowadays, cataract surgery is considered as a refractive surgery. With multifocal IOLs, spectacle independence can be achieved with a good distance, intermediate and near visual acuity. This is associated with increased quality of life after cataract surgery.The most important disadvantages of multifocal IOLs are loss of contrast sensitivity and photic phenomena such as glare and halo. Although multifocal IOLs are more frequently associated with photic disturbances than monofocal IOLs, the trifocal IOLs have improved performance in photic phenomena when compared to bifocal IOLs. Recently, a new technology known as extended depth of focus (EDOF) IOLs have been developed. These lenses create a single elongated focal point to enhance the depth of focus, improving intermediate vision without compromising distance vision. Although EDOF IOLs provide better intermediate distance vision when compared to monofocal IOLs, near vision is not as good as trifocal IOLs. The most important advantage provided by the EDOF technology is lower rate of photic disturbances than trifocal IOL designs. The aim of this study was to compare the visual performance and patient-reported quality of life (QOL) outcomes following bilateral implantation of a novel non-diffractive wavefront shaping EDOF IOL (AcrySof® IQ Vivity, Alcon Research, TX, USA) and a trifocal IOL (AcrySof® IQ PanOptix, Alcon Laboratories, Fort Worth, TX).

Interventions

DEVICEİntraocular lens implantation

Each participant underwent bilateral sequential cataract surgery and bilateral implantation of a novel non-diffractive EDOF IOL (n=26) or a trifocal IOL (n=26). The interval between the first and second-eye surgeries was 1 to 3 weeks. The patients selected the IOL model after they were fully informed regarding the advantages and disadvantages of each IOL, by their surgeon. Their degree of interest in greater spectacle freedom at far, intermediate, and near distances, as well as their daily activities such as frequency of night driving or reading habits were discussed. The possibility of photic disturbances was described and explained as well.

Sponsors

Baskent University Ankara Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Cataract patients scheduled for surgery who are interested in spectacle independence. * Bilateral cataract with plan of bilateral sequential cataract surgery. * Adult patients older than 18 years of age * Normal cognitive function, able to understand advantages and disadvantages associated with different types of IOLs.

Exclusion criteria

* Ocular diseases other than cataract including irregular astigmatism, diabetic retinopathy, age-related macular degeneration or any other retinal diseases, severe dry eye, glaucoma, amblyopia, uveitis, pseudoexfoliation syndrome, abnormal pupillary function, history of intraocular or corneal surgery, congenital eye abnormalities, or eye trauma. * Patients with high myopia with axial length (AL) ≥ 26,5 mm and high hyperopia (AL ≤ 21.5 mm) * Lifestyle and work-related factors requiring sharp near or distance vision * Patients with unrealistic visual expectations.

Design outcomes

Primary

MeasureTime frameDescription
Postoperative visual acuity with or without spectacle correction at near, far and intermediate distancespostoperative third monthuncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity (DCIVA), distance corrected near visual acuity (DCNVA)
Defocus-curvespostoperative third monthThe monocular defocus curves were evaluated under photopic conditions using defocusing lenses from +0.50 D to -4.00 D in 0.50 D steps. The measurements were performed by adding the lenses to the CDVA.
Contrast sensitivitypostoperative third monthMonocular and binocular contrast sensitivity was assessed with the Pelli-Robson chart under photopic conditions at 3 meters.
Reading speedpostoperative third monthReading speed was measured using the validated Turkish version of the MNREAD chart in photopic illumination conditions. It was recorded as number of words read by the patient in one minute (words per minute-wpm).
Quality of vision / dysphotopsiapostoperative third monthDysphotopsia was assessed by the Quality of Vision (QoV) questionnaire developed by McAlinden et al. The QoV is a validated Rasch-adjusted questionnaire in which patients are asked to rate specific dysphotopsia items depicted in standard photographs. Patients score each item (0, 1, 2, or 3) in relation to how frequent, severe, and bothersome their symptoms are (30 items in total). Lower QoV scores indicate a better quality of vision.
Vision-related quality of life (QOL)postoperative third monthThe vision-related QOL was assessed three months after the surgery by the VF-14 QOL questionnaire that was administered face-to-face by a trained researcher (İK). The grading scale was as follows: 0, no difficulty; 1, a little difficulty; 2, moderate difficulty; 3, quite difficult; 4, impossible to perform. Special care was taken not to influence the patients and to ensure that each question was fully understood.