Skip to content

A Stool DNA-based SDC2 Methylation Test for the Early Detection of Colorectal Cancer

A Multicenter, Single-blind, Prospective Clinical Trial to Evaluate the Clinical Performance of EarlyTect® CRC Test for the Early Detection of Colorectal Cancer in the Stool DNA From High-risk Group

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05255588
Enrollment
2358
Registered
2022-02-24
Start date
2022-02-10
Completion date
2024-08-30
Last updated
2025-04-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Advanced Adenomas, Advanced Colorectal Neoplasm, Colorectal Cancer, Non-advanced Adenomas, Non-neoplastic Polyps

Keywords

Colorectal cancer, SDC2, Methylation biomarker, EarlyTect® CRC test, Stool

Brief summary

The primary objective of this clinical trial is to determine the sensitivity and specificity of the EarlyTect® CRC test for detecting CRC, using colonoscopy as the reference method. The secondary objective is to compare the clinical performance of EarlyTect® CRC test with a commercially available Fecal Immunochemical Test (FIT), with respect to CRC. By histopathological examination, lesions identified during colonoscopy will be confirmed as malignant or precancerous by histological examination.

Detailed description

A multicenter, single-blind, prospective clinical trial is being conducted to evaluate the clinical performance of EarlyTect® CRC test. Subjects who are at high-risk (Asia Pacific Colorectal Screening Score ≥4.0) of developing CRC who are eligible for inclusion criteria will be asked to collect a stool sample and EarlyTect® CRC and FIT tests will be performed. For confirmation of the diagnosis and tumor staging, representative histopathology slides obtained from curative surgery and representative histopathology slides from tissue biopsied or excised during colonoscopy may be retrieved and examined by the central pathology laboratory. Methylation status of SDC2 in stool DNA is measured by a highly accurate and sensitive real time PCR that employs Linear Target Enrichment (LTE) and quantitative Methylation-Specific PCR (qMSP)(LTE-qMSP).

Interventions

DEVICEEarlyTect® CRC test

A highly accurate and sensitive real time PCR employing Linear Target Enrichment and Quantitative Methylation-Specific PCR (LTE/qMSP) for measuring SDC2 methylation in stool DNA to detect CRC.

Sponsors

Soon Chun Hyang University
CollaboratorOTHER
Gangnam Severance Hospital
CollaboratorOTHER
Kyung Hee University Hospital at Gangdong
CollaboratorOTHER
Kangbuk Samsung Hospital
CollaboratorOTHER
Kyung Hee University Hospital
CollaboratorOTHER
Keimyung University Dongsan Medical Center
CollaboratorOTHER
Korea University Anam Hospital
CollaboratorOTHER
Pusan National University Hospital
CollaboratorOTHER
The Catholic Univ. of Korea Bucheon ST. Mary's Hospital
CollaboratorUNKNOWN
Samsung Medical Center
CollaboratorOTHER
Seoul National University Hospital
CollaboratorOTHER
Asan Medical Center
CollaboratorOTHER
Wonju Severance Christian Hospital
CollaboratorOTHER
Severance Hospital
CollaboratorOTHER
Genomictree, Inc.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
40 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Subjects enrolled into the study must meet the following criteria: * Individuals who agree to voluntarily sign an informed consent prior to the initiation of screening * Adults aged ≥ 40 years * Subjects who are at high-risk (Asia Pacific Colorectal Screening (APCS) Score: 4.0\ 7.0) of developing CRC * Subjects who are able and willing to undergo colonoscopy screening within 12 months of consent among individuals who reserved a visit in the division of gastroenterology or health check-up.

Exclusion criteria

Subjects will be excluded from enrolling into the study if any of the following criteria are met: * Individuals who do not agree to voluntarily sign an informed consent prior to the initiation of screening * Adults aged \< 40 years * Subjects who are not at high-risk (APCS Score ≤ 3.0) of developing CRC * Subjects who will not undergo colonoscopy screening within 12 months of consent * Subjects who have had a positive FIT or fecal occult blood test within the previous 2 weeks * Colorectal cancer patients who did not underwent curative treatment * Subjects who have had a prior history of colorectal resection * Subjects who have had overt rectal bleeding or melena within the previous 2 weeks * Subjects who have a family history or a prior history of hereditary CRC or colorectal neoplasm: Lynch syndrome (HNPCC), familial adenomatous polyposis, MUTYH-associated polyposis, Juvenile polyposis syndrome, Peutz-Jeghers syndrome, and serrated polyposis syndrome, etc. * Subjects who have inflammatory bowel diseases including Crohn's disease, ulcerative colitis or Behcet disease * Subjects who participated in any interventional clinical study within the previous 30 days * Subject has any condition which, in the opinion of the medical staff should preclude participation in the study

Design outcomes

Primary

MeasureTime frameDescription
Sensitivity and specificity of the EarlyTect® CRC test for detecting CRC compared to the colonoscopy, both in terms of detecting CRC.18 monthsThe reference method is the colonoscopy, and lesions will be assessed histopathologically. EarlyTect® CRC test includes a measurement of SDC2 methylation and COL2A1 as a DNA control. SDC2 methylation in stool DNA will be assessed quantitatively by LTE/qMSP. The results will be dichotomized by the CT (cycle threshold) cutoff value as either positive or negative. Sensitivity = 100\*(positive SDC2 methylation test/positive colonoscopy), Specificity = 100\*(negative SDC2 methylation test/negative colonoscopy).

Secondary

MeasureTime frameDescription
Sensitivity of EarlyTect® CRC for detecting advanced colorectal neoplasm18 monthsSensitivity for detecting adenomas ≥1.0 cm
Sensitivity of EarlyTect® CRC for detecting non-advanced adenomas18 monthsSensitivity for detecting non-adenomas \<1.0 cm
Sensitivity and specificity of combined FIT and EarlyTect® CRC tests in detecting CRC18 monthsSensitivity and specificity of combined FIT and EarlyTect® CRC tests in detecting CRC
Sensitivity of EarlyTect® CRC for detecting advanced colorectal adenoma (Adenomas ≥1.0 cm, villous adenomas or high-grade dysplasia)18 monthsSensitivity for detecting adenomas ≥1.0 cm * Sensitivity of EarlyTect® CRC for detecting villous adenomas * Sensitivity of EarlyTect® CRC for detecting high-grade dysplasia
Clinical specificity of EarlyTect® CRC when patients with non-advanced adenomas and non-advanced colorectal serrated lesions are included in control group18 monthsClinical specificity of EarlyTect® CRC when patients with non-advanced adenomas and non-advanced colorectal serrated lesions are included in control group
Clinical sensitivity of the EarlyTect® CRC for detecting Tis18 monthsClinical sensitivity of the EarlyTect® CRC for detecting colorectal cancer with Tis
Sensitivity of EarlyTect® CRC for detecting advanced colorectal serrated lesions18 monthsSensitivity of EarlyTect® CRC for detecting advanced colorectal serrated lesions

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026