Enterprise 2 Vascular Reconstruction Device

Treatment of Intracranial Wide-neck Aneurysms Using Stent-assisted Coil Embolization With the Codman Enterprise 2 Vascular Reconstruction Device.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05254067
Enrollment
10
Registered
2022-02-24
Start date
2017-02-28
Completion date
2026-01-05
Last updated
2026-05-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aneurysm

Brief summary

The primary objective of this study is to collect data regarding the effectiveness of using the Enterprise 2 Reconstruction Device in successfully embolizing intracranial aneurysms with wide neck configuration.

Detailed description

The Codman Enterprise 2 Vascular Reconstruction Device is a self-expanding nitinol, compliant, closed-cell, recapturable design that can be deployed by a single operator. The Codman Enterprise 2 Vascular Reconstruction Device is packaged sterile as a single unit with an introducer sheath and a detachable push wire. This device was designed to assist in the stent-assisted coil embolization of intracranial aneurysms, specifically those that have a wide neck that would not otherwise maintain the coil embolization material within the aneurysm because of the wide opening at the base of the aneurysm. The Codman Enterprise 2 Vascular Reconstruction Device is approved by the FDA as a Humanitarian Use Device (HUD) in cases of wide-necked saccular cerebral aneurysms. The primary objective of this study is to collect data regarding the effectiveness of using the Enterprise 2 Reconstruction Device in successfully embolizing intracranial aneurysms with wide neck configuration. Secondly, to determine any safety or delivery problems that may occur, or any adverse patient events that may have previously been undocumented.

Interventions

DEVICECodman Enterprise 2 Vascular Reconstruction Device

a self-expanding nitinol, compliant, closed-cell, recapturable design that can be deployed by a single operator designed to assist in the stent-assisted coil embolization of intracranial aneurysms, specifically those that have a wide neck that would not otherwise maintain the coil embolization material within the aneurysm because of the wide opening at the base of the aneurysm.

Sponsors

Methodist Health System
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients (18 years old or older) with intracranial aneurysms with a wide neck (defined as \> or = to 4mm, or with a dome to neck ratio of 2:1 or greater).

Exclusion criteria

* Small-necked aneurysms, inappropriate for stenting. * Inability to tolerate anti-platelet medication.

Design outcomes

Primary

MeasureTime frameDescription
Device Effectiveness-Stent MigrationPatients will be followed for a minimum period of 2 years from the date of the procedure, with planned total duration of 4 years of the study, including follow-up time.Prior Observation studies have noted in other stents, that over time, a stent may migrate from its original location, given the flow dynamics and potentially from stent under-sizing. This could potentially disrupt flow through the artery, or even uncover the aneurysm, openining, potentially allowing outflow of embolization coils.
Device Effectiveness- Stent Fore-shorteningPatients will be followed for a minimum period of 2 years from the date of the procedure, with planned total duration of 4 years of the study, including follow-up time.If a stent contracts slightly after placement, then it could shorten slightly, particularly if the stent is placed around a tortous corner. In this type of event, generally there is no significant impact to the patient, unless the stent were to shorten and uncover the opening of the aneurysm, potentially allowing embolization coils to come out of the aneurysm.
Device Effectiveness- In-stent stenosisPatients will be followed for a minimum period of 2 years from the date of the procedure, with planned total duration of 4 years of the study, including follow-up time.In this known phenomenon with stents, it is possible that either through local inflammatory reaction or by hyper neointimalization, there can be a buildup of materila on the inner lumen of any stent that is placed.

Countries

United States

Contacts

PRINCIPAL_INVESTIGATORBartley Mitchell, MD

Methodist Dallas Medical Center Neurovascular Surgery