Fetal MRI Acquisition and Sequence Development

Fetal MRI Acquisition and Sequence Development

Status
Withdrawn
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05253742
Acronym
FMASD
Enrollment
0
Registered
2022-02-24
Start date
2023-05-31
Completion date
2026-05-31
Last updated
2026-06-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pregnancy Related

Keywords

MRI, Fetus, Uterus, Placenta, Brain

Brief summary

Testing of new magnetic resonance imaging (MRI) pulse sequences (image acquisition software) for imaging the fetus to improve workflow and image quality in fetal imaging and diagnosis. The investigators would like to develop novel MRI approaches to enhance fetal imaging with MRI, in the presence of motion. As part of technical development, the investigators plan to develop methods to improve structural T1 and T2 weighted images, MR angiography, diffusion and spectroscopy measurements of the fetus.

Detailed description

Fetal MRI has become a critical tool for both studying the early development of the human brain and resolving diagnostic ambiguities that may remain after routine ultrasound exams. Due to its excellent soft-tissue contrast and the absence of harmful ionizing radiation, MRI is preferable to computed tomography for neuroimaging. Unfortunately, fetal and maternal motion limit fetal MRI to rapid two-dimensional (2D) sequences with thick slices such as half-Fourier single-shot turbo spin echo (HASTE). Although these sequences decrease the impact of motion during the sub-second acquisition of individual slices, multiple slices are needed, and contiguous orthogonal scans are challenging as motion occurs between slices. Typically, \>38% of acquisitions are discarded because of corrupted geometry and artifacts. In this project the investigators will develop software that runs on the Siemens MRI scanner. This software will improve the workflow for fetal imaging i.e. for imaging the fetus in utero. Fetal imaging in its current form is inefficient due to the frequent motion of the fetus during the imaging procedure. In this project the investigators will develop automated methods for alignment and tracking of the fetus during imaging, to more efficiently image the fetus and to obtain better image quality in a shorter examination. The investigators are specifically interested in the fetal brain, but these methods may be generalized to all fetal organ systems. The investigators will install the software on the scanner and test these methods with volunteers.

Interventions

OTHERNo intervention - the investigators are evaluating a new image acquisition method on an MRI scanner

The investigators will evaluate the performance of a modified MRI acquisition method against an existing method in fetal imaging in volunteers

Sponsors

Massachusetts General Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
13 Weeks to 40 Weeks
Healthy volunteers
Yes

Inclusion criteria

Eligibility will be determined prior to the scan session by a pre-screening interview conducted either via telephone or in person asking about MR contraindications. Participants will be excluded from study entry or study completion when any of the following

Exclusion criteria

are met at any time of screening or enrollment: * Claustrophobia sufficient to interfere with MRI or render the subject unable to complete an MRI scan * MRI contraindications (e.g., magnetically or mechanically activated implants) * Weight greater than or equal to 300lbs (weight limit of the MRI table) * Non-English speaking * Neurological conditions (i.e. epilepsy, multiple sclerosis, neurodegenerative diseases, memory disorders, brain tumor) * Past incidence of stroke or heart attack * Severe hypertension, blood disorders, advanced diabetes mellitus, or advanced cardiovascular disease * Hospitalization within 6 weeks prior to enrollment * Significant acute and/or chronic medical conditions, current use of medications that indicate the existence of significant medical conditions, and other unspecified reasons that make the subject unsuitable for enrollment at the discretion at the PI and a consulting MD. Pregnant mothers with the following features will be excluded. * Mothers with contraindication to MRI (such as pacemaker, metal in body, exceeding scanner weight or bore diameter limits (550lbs, 70cm)) * Mothers with claustrophobia * Mothers medically unstable for the MRI study

Design outcomes

Primary

MeasureTime frameDescription
Image alignment in fetal MRIFive year K99/R00 projectEvaluation of image alignment with automatical positioning in MRI
Tracking quality in fetal MRIFive year K99/R00 projectEvaluation of image quality with motion tracking in MRI

Outcome results