Skip to content

DK Score Coronary Scoring Balloon: a RCT Trial to Evaluate Acute Lumen Gain (SCORE CHINA)

A Prospective, Multi-center, Randomized Study to Evaluate the Safety and Efficacy of DK ScoreTM Scoring Balloon Vesus Non-Slip Element Coronary Dilatation Catheter for Coronary Artery Stenosis

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05250193
Enrollment
200
Registered
2022-02-22
Start date
2021-03-24
Completion date
2021-12-30
Last updated
2022-03-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Stenosis

Keywords

Scoring balloon; DK Score; NSE

Brief summary

A prospective, Multi-center, Randomized Study designed to evaluate the acute lumen gain and device procedural success of the DK ScoreTM Scoring balloon versus NSE Scoring Balloon for patients with coronary arteries stenosis.

Detailed description

This is a prospective, multi-center, randomized controlled, open-label, noninferior study to evaluate Acute Lumen Gain after dilatation. A total of 200 patients will be enrolled from 4 sites in China. All patients enrolled will be randomly assigned to the test group (DK ScoreTM group, n=100) and the control group (NSE group, n=100) with randomized allocation ratio of 1:1. Patients in the test group and the control group will be treated with DK ScoreTM Scoring balloon catheters or NSE Coronary Dilatation Catheter. A 30-day after procedure follow-up will be conducted for all 200 patients.

Interventions

DEVICEDK ScoreTM Coronary Scoring Balloon

After pre-dilation balloon is used (if any), DK Score is used as final dilatation balloon before Drug Eluting Stent implantation or Drug Coated Balloon deployment.

DEVICENon-Slip Element Coronary Dilatation Catheter

After pre-dilation balloon is used (if any), NSE is used as final dilatation balloon before Drug Eluting Stent implantation or Drug Coated Balloon deployment.

Sponsors

DK Medical Technology (Suzhou) Co., Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

Patients related 1. Age ≥ 18 years and ≤ 75 years. 2. Patients with symptomatic coronary artery disease with stable and unstable angina pectoralis remote myocardial infarction , asymptomatic subjects with coronary atherosclerotic stenosis causing myocardial ischemia. 3. Patients with indications for coronary artery bypass grafting. 4. Patients are able to follow protocol requirements and data collection procedures 5. Patients understand the purpose of the study, will voluntarily participate in the study and sign informed consent. Patients are willing to undergo clinical follow-up as required by this study. Lesions Related: 1. Reference vessel diameter (RVD) between 2.0 and 4.0 mm by visual estimation.. Target lesion length ≤ 20 mm. 2. More than 70% stenosis (or more than 50% stenosis combined with symptoms of ischemia). TIMI≥1. 3. One target lesion needs to be Treated. Treatment of non-target lesion, if any, must be completed prior to treatment of target lesion and must be deemed a clinical angiographic success as visually assessed by the physician. The non-target lesion need be located at another coronary artery different from the target lesion. 4. Investigator estimates that the target lesion need Cutting/Scoring balloon treatment. Target lesion is fully pre-dilated that scoring balloon is able to pass.

Exclusion criteria

Patients Related : 1. AMI within 1 week. 2. Patients has congestive heart failure or NYHA IV. 3. Renal dysfunctional (CRE\>443umol/L). 4. Patient underwent heat transplant. 5. Pregnant or nursing. 6. Lifespan expectancy is less than 12 months 7. Patients with history of peptic ulcer or gastrointestinal bleeding, or the patients have a bleeding tendency evaluated by investigator. Patients are forbidden to use anticoagulation agents or anti-platelet drugs. 8. Patients are allergic to paclitaxel or heparin 9. Difficult for evaluation or treatment. 10. Patents are currently participating in another investigational drug or device study that has not yet completed its primary endpoint. 11. Patients participated in any other clinical trials less than 1 month. 12. Interventional surgery is expected to be extremely risky unsuitable for study evaluated by investigator. 13. Patient had poor compliance record and could not follow the study. Lesion Related: 1. Target Lesion located in Left Main Artery lesions and Ostial lesion within 5mm to Left Main Artery. 2. Angiography shows thrombus in Target Lesion 3. Chronic Total Occlusion Lesion

Design outcomes

Primary

MeasureTime frameDescription
Numerical Acute Lumen Gain in mm (QCA)During the procedureAcute Lumen Gain for both arms will be measure with QCA, as accessed by independent core-lab. Angiographic endpoint will be in-lesion acute lumen gain defined as minimal lumen diameter (MLD) in lumen after dilatation by either arm device minus baseline MLD.

Secondary

MeasureTime frameDescription
Rate of Device success in percentDuring the procedureSuccessful delivery to the target lesion, deployment, achieving less than 50% residual stenosis, and retrieval after procedure.
Rate of Target Lesion Failure in percent30±7 DaysDefined as any Target Lesion Failure after procedure
Rate of Patient-oriented Composite Endpoint (POCE) in percent30±7 DaysPatient-oriented Composite Endpoint after procedure
Rate of other Complications in percentDuring the procedureIncidence of complications associated with the use of scoring balloon catheters
Rate of Clinical Success in percentDuring the procedureDefined as \<20% diameter stenosis after stenting for DCB, without in-hospital major adverse cardiac events/MI/TLR After PCI

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026