Respiratory Rate Validation Study - ChroniSense Polso

Respiratory Rate Validation Study - ChroniSense Polso

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05246358
Enrollment
20
Registered
2022-02-18
Start date
2021-05-10
Completion date
2021-06-11
Last updated
2022-02-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Respiratory Rate

Brief summary

20 volunteer test subjects entered into an accuracy study that is designed to validate accuracy of the respiratory rate of the ChroniSense Polso

Detailed description

20 volunteer test subjects entered into an accuracy study that is designed to validate accuracy of the respiratory rate of the ChroniSense Polso. A range of stable respiratory rates were elicited from each volunteer test subject. The rates will be approximately 5, 10, 15, 20, 25, 30, 35, 40 and 45 breaths per minute; with some natural variation from these exact numbers. Each subject was instrumented with an open system mask that allows for measurement of the end tidal carbon dioxide (EtCO2) respiratory rate and tidal volume. The EtCO2 monitor was used as the Accuracy Reference Device (Reference) in this study.

Interventions

DEVICEChoniSense Polso

A range of stable respiratory rates was elicited from each volunteer test subject. The rates were 5, 10, 15, 20, 25, 30, 35, 40 and 45 breaths per minute; with some natural variation from these exact numbers. Each subject was instrumented with an open system mask that allows for measurement of the end tidal carbon dioxide (EtCO2) respiratory rate and tidal volume. The EtCO2 monitor was used as the Accuracy Reference Device (Reference) in this study.

Sponsors

ChroniSense Medical Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 52 Years
Healthy volunteers
Yes

Inclusion criteria

* Subject must have the ability to understand and provide written informed consent * Subject is adult over 18 years of age * Subject must be willing and able to comply with study procedures and duration * Subject is a non-smoker, or a smoker who has refrained from smoking for 1 day. * Male or female of any race

Exclusion criteria

Compromised circulation, injury, or physical malformation of fingers, toes, hands, ears or forehead/skull or other sensor sites which would limit the ability to test sites needed for the study. Tattoo in the optical path which would limit the ability to test sites needed for the study. (Note: Certain malformations may still allow subjects to participate if the condition is noted and would not affect the particular sites utilized.) * Subjects with known respiratory conditions such as: * uncontrolled / severe asthma, * flu, * pneumonia / bronchitis, * shortness of breath / respiratory distress, * respiratory or lung surgery, * emphysema, COPD, lung disease * Subjects with self-reported heart or cardiovascular conditions such as: * high blood pressure: systolic \>140 mmHg or diastolic \>90 mmHg * have had cardiovascular surgery * chest pain (angina) * heart rhythms other than a normal sinus rhythm or with respiratory sinus arrhythmia * previous heart attack * blocked artery * unexplained shortness of breath * congestive heart failure (CHF) * history of stroke * transient ischemic attack * carotid artery disease * myocardial ischemia * myocardial infarction * cardiomyopathy * Self-reported health conditions as identified in the Health Assessment Form * diabetes, * uncontrolled thyroid disease, kidney disease / chronic renal impairment, * history of seizures (except childhood febrile seizures), * epilepsy, * history of unexplained syncope, * recent history of frequent migraine headaches, * recent head injury within the last 2 months, * Cancer / chemotherapy * Other known health condition, should be considered upon disclosure in health assessment form

Design outcomes

Primary

MeasureTime frameDescription
Arms accuracy (breaths per minute) of Polso Monitoring System relative to End Tidal Carbon Dioxide monitor-derived respiration rateThrough study completion, 1 month averageAccuracy of Polso Monitoring System (DUT) relative to a reference End Tidal Carbon Dioxide monitor-derived respiration rate (REF). Polso reports respiration rate (breaths per minute) directly, at 60 second intervals. End Tidal Carbon Dioxide monitor waveforms will be hand-scored, based on respiration waveform peaks, to derive respiration rate (breaths per minute). The readings from each device will be synchronized to achieve paired simultaneous respiration rates, and aggregated into calculation of a comparative accuracy measure, namely Accuracy root-mean-square (Arms) difference, in breaths per minute, between the Polso (DUT) and the reference (REF) respiratory rate system, for all stable respiratory periods. Acceptance criteria Arms \<3.

Countries

United States

Outcome results

None listed