Skip to content

Current Practice of Patients Undergoing C-arm Procedures at the Operating Department

Baseline Study on Current Practice of Patients Undergoing C-arm Procedures of Extremities or Spinal Cord at the Operating Department of the Maastricht University Medical Center+

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05238129
Enrollment
540
Registered
2022-02-14
Start date
2022-05-01
Completion date
2023-02-28
Last updated
2022-04-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

High Complex (Lower Extremities & Spinal Cord), Low Complex (Lower & Upper Extremities), Types of C-arm Procedures Included

Brief summary

All x-ray systems at the MUMC+ are currently operated by radiodiagnostic technicians. This is also the case for C-arms used during surgical procedures at the OR-complex. Because a gain in time efficiency is expected (i.e. not for research related reasons), a group of OR-personnel will be in-house trained to qualify for operating C-arms in low complex procedures. The shift towards C-arm procedures performed by OR personnel has been initiated also in other hospitals as it is expected to be time saving without loss of quality. However, this is an assumption and not proven by any scientific evidence. Several aspects are interesting for scientific studies as little is known about the effects of this shift on image quality, radiation dose, time efficiency and to guarantee that there is no loss of quality for the patient. This study investigates the standard care, where radiodiagnostic technician operate the C-arms. This study is set up such that it can serve as a baseline for a future study in which it will be assessed whether the quality of care when OR-personnel operates the C-arms is non-inferior to the standard care. The aim of the study is to prospectively assess the standard care. Research questions are twofold: 1. What is the current practice and current time efficiency of C-arm procedures performed by radiodiagnostic technicians? 2. What is the current quality of C-arm procedures operated by radiodiagnostic technicians?

Interventions

OTHERNo intervention - standard care is assessed

No intervention - standard care is assessed

Sponsors

Maastricht University Medical Center
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* All C-arm OR-procedures performed at the OR-complex of the MUMC+; * Type of procedure is: low complex: extremities (upper or lower), high complex: lower extremities, spinal cord (four procedure types).

Exclusion criteria

* No informed consent; * Incomplete procedure information and technical parameters; * Withdrawal of informed consent by the study patient.

Design outcomes

Primary

MeasureTime frameDescription
Gross and nett OR time [minutes]1 dayMeasures for time efficiency, recorded by assistent investigator during procedure
Radiation dose (DAP[Gycm2])1 dayMeasure for quality

Secondary

MeasureTime frameDescription
Occupancy time C-arm [minutes]1 dayMeasure for efficiency, recorded by assistent investigator during procedure
Downtime (technical failures) [minutes]1 dayMeasure for efficiency, recorded by assistent investigator during research period
Number of revision surgeries1 monthMeasure for quality, recorded by assistent investigator 1 month after the procedure
Radiation dose (Dose in ref_point [mGy])1 dayMeasure for quality, obtained from C-arm
Time spent by and type of personnel involved [minutes, predefined role]1 dayMeasure for efficiency, recorded by assistent investigator during procedure
Number and type of help requests1 dayMeasure of quality and efficiency, recorded by assistent investigator during procedure
Collimation [cm2]1 dayMeasure for quality, obtained from the C-arm (= used field size)
Radiation related procedure time (beam on, fluoroscopy and acquisition time) [seconds]1 dayMeasure for quality, obtained from the C-arm
Number and types of events1 dayMeasure for quality, obtained from the C-arm
Image quality subjective scoring1 dayMeasure for quality, questionaire, Likert scale 1-5 (5 being highest quality)
Amount of time spent inefficiently [minutes]1 dayMeasure for efficiency, recorded by assistent investigator during procedure

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026