Skip to content

ContraBand™: Safety & Feasibility Study (RM-20-01)

ContraBand™ Safety & Feasibility Study for Treatment of Heart Failure

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05230745
Enrollment
55
Registered
2022-02-09
Start date
2021-09-28
Completion date
2032-12-31
Last updated
2026-02-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure, Left Sided

Keywords

pulmonary artery banding

Brief summary

ContraBand™ is a transcatheter constriction device which is implanted in the left and right branch pulmonary arteries. The effect is achieved by causing a local reduction in the internal diameters of the branch PAs, resulting in a lower distal systolic pulmonary artery pressure (PAP) as well as an attenuation in the rise of the mean pulmonary capillary wedge pressure (PCWP) along with a higher pulmonary arterial compliance (PAC) distal to the constriction during exercise. Lower PCWP reflects the reduced left ventricular end diastolic pressure (LVEDP), contributing to enhanced ventricular filling and improved cardiac output. This hemodynamic change is anticipated to translate into enhanced physical capacity and a potentially more favorable prognosis for heart failure subjects. This study is an early feasibility, multi center, prospective, interventional, open-label, single-arm study.

Interventions

DEVICEContraBand implants

Percutaneous implantation of the ContraBand devices by right heart catheterization

Sponsors

Restore Medical Ltd
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

Main Inclusion Criteria: * Age is 18 - 85 years old * Chronic heart failure (\> 3 months) * Symptomatic left heart failure Stage C (NYHA Class III-IVa) or Class II with documented prior history of Class III-IVa heart failure. * LVEF 20 - 40% * Receiving optimally tolerated GDMT for at least 3 (three) months as referred in the 2021 ESC Guidelines for the optimal recommended pharmacological treatment indicated in patients with (NYHA class II-IV) heart failure with reduced ejection fraction (LVEF\< 40%). * If indicated according to the 2021 ESC Guidelines: Subject has an implantable cardioverter-defibrillator (ICD) for at least 1 month prior to screening. or subject is on cardiac resynchronization therapy (CRT)/pacemaker for at least 3 months prior to screening. * Able to complete six-minute walk test (6MWT) with distance between 100 meters and 400 meters. Main

Exclusion criteria

* Serum NT-proBNP \<300 pg/mL * Significant RV dysfunction with TAPSE \< 15 mm * Moderate to severe pulmonary hypertension (Pulmonary vascular resistance PVR ≥ 4.0 WU and PAPi \< 1.0 by RHC) * Anatomical pathology or constraints preventing appropriate access/implant of ContraBand™ * Restrictive Cardiomyopathy or myocarditis * Any severe valve disease (Grade 3-4) and/or tricuspid regurgitation ≥ 2+ (in a scale of 5) * Hemodynamic instability: Hypotension (systolic pressure \<90 mmHg) or requirement for inotropic support or mechanical hemodynamic support * Active bacterial endocarditis or previous history of SBE (Subacute bacterial endocarditis) * Any planned cardiac surgery or interventions within the next six (6) months * Need for coronary artery revascularization * Myocardial infarction or any percutaneous cardiovascular intervention within 1 month * Cardiovascular surgery, or carotid surgery within 3 months * Acute kidney insufficiency and/or end stage renal disease requiring chronic dialysis (eGFR \< 30) * Leukopenia (WBC \< 4000 cells/μL), anemia (Hgb \< 9 g/dL), thrombocytopenia (platelets \< 150,000 cells/μL) or any known blood clotting disorder * History of systemic or pulmonary thromboembolism within 12 months prior to Baseline visit; incidental small peripheral pulmonary emboli deemed clinically insignificant by the investigator are not considered exclusionary * Previous history of cardiogenic shock (unrelated to myocardial infraction) * Stroke, transient ischemic attack (TIA) or deep vein thrombosis (DVT) within 6 months of screening

Design outcomes

Primary

MeasureTime frameDescription
Device-related or procedure-related major adverse events (MAEs)30 daysMAE is a composite of death; myocardial infarction; emergent conversion to surgery; stroke; major cardiac structure complication; major vascular complication; embolization and heart failure- related hospitalization.

Secondary

MeasureTime frameDescription
Procedural successImplantation procedureAbility to successfully deliver devices to the Pulmonary Arteries

Countries

Belgium, Georgia, Germany, Israel, Lithuania, Poland

Contacts

CONTACTStephen Bellomo
stephen@restoremedical.co+972 54 227 4831

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 6, 2026