Skip to content

Feasibility Trial of Magnetic-assisted Colonoscope Platform

Feasibility Trial of Magnetic-assisted Colonoscope Platform

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05213741
Enrollment
10
Registered
2022-01-28
Start date
2024-05-31
Completion date
2024-12-31
Last updated
2023-04-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Colonoscopy, Colorectal Cancer

Keywords

Colonoscopy, Magnetic-assisted

Brief summary

Colorectal cancer (CRC) screening program can reduce colon cancer-related mortality. Current CRC screening methods include stool occult blood and DNA testing, blood based tests and radiologic tests. Colonoscopy is considered the gold standard to detect colorectal neoplasms. Previous studies have estimated that cancer mortality to be 68% to 88% lower among persons who undergo screening colonoscopy than among those who do not. However, colonoscopy is an invasive examination, and 10% to 20% of patients fail to tolerate the procedure; therefore, greatly reduces the success rate of completion of colon examination. External controllability of capsule endoscope by means of an applied magnetic field is a possible solution to the maneuvering problem. However, there is no effective system with straight forward clinical applicability till now. This is ascribable to a lack of reliable magnetic instrumentation suitable for such a purpose. We have reported that magnetic field navigator (MFN) can effectively control the locomotion of capsule endoscope. We have demonstrated the feasibility and safety of magnetic-assisted capsule endoscope for the examination of upper gastrointestinal tract. In this study, we develop a magnetic-assisted capsule colonoscope by combination of the integrated circuit complementary metal-oxide-semiconductor imaging sensor, light-emitting diode, and magnetic control technology. This magnetic-assisted capsule colonoscope operation system includes a MFN Platform, high-end hand-controlled joystick, combined circuit component, control interface and software. This magnetic-assisted capsule colonoscope operation system creates a friendly operating environment for the operators, and may establishe a novel screening system for the colon.

Detailed description

1. Preparation before examination: All subjects must take bowel cleansing drugs as instructed before magnetically controlled colonoscopy After starting to drink laxatives, subjects should continue their daily activities . 2. Magnetically Controlled Colonoscopy procedure: No anesthesia will be used during the magnetically controlled colonoscopy in this experiment. The subjects lie down on the magnetic control colonoscopy platform. After the magnetically controlled colonoscopy enters the rectum from the subject's anus, the external magnetron is used to assist and guide the pre-colonoscopy after the magnetically controlled colonoscopy enters the rectum from the subject's anus, and the external magnetron is used to assist and guide the colonoscopy go ahead. During the inspection process, the physician monitors the operation of the magnetically controlled colonoscope throughout the process, and the physician can adjust the movement of the colonoscope when necessary. Whole colorectal examination is defined as the colonoscope must be inserted into the ileocecal region, and the cecum must be photographed. 3. Pain assessment during examination: During the colonoscopy, the researchers will conduct a questionnaire to the patients to assess the pain.. The evaluation method is based on the Verbal Scale to evaluate the maximum discomfort, from 0 to 10 points; ; Among them, 0 points are painless, 10 points are the most severe. If the patient's pain assessment score is greater than 5 and the patient cannot tolerate colonoscopy, the examination will be terminated. If there are difficulties during the examination, and the magnetic-controlled colonoscopy cannot complete the examination within 1 hours, the examination shall be terminated. 4. After the colonoscopy is completed, the researcher conducts an overall pain assessment to the subjects by means of a questionnaire. On the day after the colonoscopy, the researcher asked the subjects whether they would like to accept the next colonoscopy follow-up examination by means of a questionnaire. 5. After the magnetic-controlled colonoscopy, the images and time recorded by the colonoscopy will be interpreted by computer-captured images, and the completion rate of the magnetic-controlled colonoscopy will be analyzed.

Interventions

DEVICEAutonomous navigation of a magnetic colonoscope

The proposed magnetic-assisted colonoscope system consists of an megnetic field nevigator, magnetic-assisted colonoscope, and image receiving decoder. All participants will receive the magnetic-assisted colonoscopic examination by using this proposed magnetic-assisted colonoscope system

Sponsors

Ministry of Health and Welfare, Taiwan
CollaboratorOTHER_GOV
Taipei Medical University WanFang Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

Aged 20-65 health volunteers without any contraindication

Exclusion criteria

1. Person allergy to polyethylene glycol. 2. Phenylkentouria 3. Congestive heart failure (NYHA grade 3) 4. Renal function impairment. 5. Difficulty in swallowing, GI perforation, GI bleeding, toxic enterocolitis, toxic colitis, megacolon, diverticulitis, peritonitis 6. Body weight less than 20kg 7. Wrist more than 120cm 8. Gastrointestinal tract obstruction 9. Pregnant woman. 10. Person with electrical medical implantation such as pacemaker, cochlear implant or other medical devices. 11. Person implanted with metal medical device such as metal implantation, metallic stent, metallic denture, metallic valve, metallic joint, metallic joint or plate. 12. Person with history of abdominal surgery. 13. Person with cancer. 14. Person with bleeding tendency 15. Person with asthma 16. History of cardiac infraction, pulmonary embolism, stroke in recent 6 months 17. Heart failure with NYHA grades 4

Design outcomes

Primary

MeasureTime frameDescription
Feasibility of magnetic-assisted colonoscope systemThe end of colonoscopic examinationThe completion rate of colonoscopic examination by using the magnetic-assisted colonoscope system
Safety of magnetic-assisted colonoscope systemThe end of colonoscopic examinationThe complication rate of colonoscopic examination by using the magnetic-assisted

Contacts

Primary ContactFAT-MOON SUK, M.D.
sukfm@yahoo.com+886229307930

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026