Skip to content

Cutaneous Hydration Assessment in SCD

Cutaneous Hydration Assessment in Sickle Cell Disease

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05210114
Enrollment
30
Registered
2022-01-27
Start date
2022-01-21
Completion date
2027-12-31
Last updated
2025-11-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sickle Cell Disease

Brief summary

This study will validate the diagnostic accuracy of a cutaneous hydration sensor. This sensor will also be evaluated for its feasibility as a point-of-care device for the assessment of hydration status and its potential to guide hydration therapy in patients with sickle cell disease (SCD).

Detailed description

Vaso-occlusive episodes (VOE) are the leading cause of hospitalization for patients with SCD. Intravenous fluid replacement is one of the cornerstones of management of VOE in the emergency department and throughout hospitalization. However, there are no evidence-based guidelines specifying the optimal administration of maintenance fluids. Overly aggressive hydration therapy imparts the risk of hypervolemia and pulmonary edema, which may lead to acute chest syndrome and death. Thus, a reliable biomarker is needed to gauge hydration status and guide fluid replacement strategies with the goal of achieving euvolemia. The investigators propose a point-of-care test that may inform management (e.g., bolus vs. continuous infusion of maintenance intravenous fluid), and prevent over- or under-hydration. For this purpose, investigators seek to validate the diagnostic accuracy of a cutaneous hydration sensor, Delfin MoistureMeterEpiD (a non-significant risk device) and evaluate its feasibility as a point-of-care device for the assessment of hydration status and potentially guide hydration therapy in patients with SCD. Investigators will measure skin hydration in the clinic when participants are at baseline state of health. Skin hydration before and after fluid resuscitation therapy in patients with vaso-occlusive crisis (VOC) or VOE will also be assessed. Blood and urine will be collected to compare assessments of skin hydration with laboratory biomarkers of hypertonicity and red blood cell dehydration.

Interventions

DEVICESkin Hydration Sensor

The device is a skin hydration sensor. The sensor is placed on the skin at the inner arm. It is non-invasive and measures in seconds the percent water content of the dermis by quantifying its dielectric constant.

Sponsors

Enrico Novelli
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
12 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Diagnosis of Sickle Cell Disease (genotypes SS, SC, Sß-thalassemia, SD, SOArab) * Participants must be ≥12-years old * Participants that provide legally effective consent to all study procedures

Exclusion criteria

* Participants under 12-years old * Participants being treated with experimental therapies in clinical trials

Design outcomes

Primary

MeasureTime frameDescription
Dermal water content measurements in SCD participants at baseline state of healthDuring a regularly scheduled clinic appointment, approximately 2 hoursDelfin MoistureMeterEpiD hydration sensor will be used to measure dermal water content in 20 participants at 1 time point.
Dermal water content measurements before fluid resuscitation in SCD participants with VOC or VOEDuring a VOC or VOE event before IV fluid resuscitation, approximately 2 hoursDelfin MoistureMeterEpiD hydration sensor will be used to measure dermal water content in 10 participants.
Dermal water content measurements after fluid resuscitation in SCD participants with VOC or VOEDuring a VOC or VOE event after IV fluid resuscitation, approximately 2 hoursDelfin MoistureMeterEpiD hydration sensor will be used to measure dermal water content in 10 participants.
Clinical dehydration assessments in SCD participantsAt a regularly scheduled clinical appointment, approximately 2 hoursClinical assessment of dehydration will be ascertained by administering the 10-point Clinical Dehydration Scale (CDS). CDS uses clinical characteristics (general appearance, eyes, mucous membranes, and tears), each of which are scored 0, 1, or 2 for a total score of 0 to 8, with 0 representing no dehydration; 1 to 4, some dehydration; and 5 to 8, moderate/severe dehydration. It will be administered at 1 time point in 20 participants.
Measurement of serum osmolality as a laboratory biomarker of dehydration in SCD participantsAt a regularly scheduled clinical appointment, approximately 2 hoursSerum osmolality values of \>290 milliosmol/kg is considered abnormal. It will be measured at 1 timepoint in 20 participants.
Measurement of hyperadhesion as a laboratory biomarker of dehydration in SCD participantsAt a regularly scheduled clinical appointment, approximately 2 hoursAs a marker of hyperadhesion capillary transit time will be measured using capillary mimicking microfluidic channels. It will be measured at 1 timepoint in 20 participants.
Measurement of elongation index as a cellular biomarker of dehydration in SCD participantsAt a regularly scheduled clinical appointment, approximately 2 hoursCellular dehydration marker, the elongation index, will be measured by ektacytometry. It will be measured at 1 timepoint in 20 participants.
Measurement of point of sickling as a biomarker of dehydration in SCD participantsAt a regularly scheduled clinical appointment, approximately 2 hoursPoint of sickling, a cellular dehydration biomarker, will be measured by ektacytometry. It will be measured at 1 timepoint in 20 participants.
Measurement of urine osmolality as a laboratory biomarker of dehydration in SCD participantsAt a regularly scheduled clinical appointment, approximately 2 hoursUrine osmolality values \<450 milliosmol/kg is considered abnormal in adults without fluid restrictions. It will be measured at 1 timepoint in 20 participants.
Measurement of serum osmolality as a laboratory biomarker of dehydration before resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event before resuscitation therapy, approximately 2 hoursSerum osmolality values of \>290 milliosmol/kg is considered abnormal. It will be measured at 1 timepoint in 10 participants.
Measurement of serum osmolality as a laboratory biomarker of dehydration after fluid resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event after fluid resuscitation therapy, approximately 2 hoursSerum osmolality values of \>290 milliosmol/kg is considered abnormal. It will be measured at 1 timepoint in 10 participants.
Measurement of hyperadhesion as a laboratory biomarker of dehydration before fluid resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event before fluid resuscitation therapy, approximately 2 hoursAs a marker of hyperadhesion, capillary transit time will be measured using capillary mimicking microfluidic channels. It will be measured at 1 timepoint in 10 participants.
Measurement of hyperadhesion as a laboratory biomarker of dehydration after fluid resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event after fluid resuscitation therapy, approximately 2 hoursAs a marker of hyperadhesion, capillary transit time will be measured using capillary mimicking microfluidic channels. It will be measured at 1 timepoint in 10 participants.
Measurement of elongation index as a cellular biomarker of dehydration before resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event before fluid resuscitation, approximately 2 hoursCellular dehydration marker, the elongation index, will be measured by ektacytometry. It will be measured at 1 timepoint in 10 participants.
Measurement of elongation index as a cellular biomarker of dehydration after fluid resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event after fluid resuscitation therapy, approximately 2 hoursCellular dehydration marker, the elongation index will be measured by ektacytometry. It will be measured at 1 timepoint in 10 participants.
Measurement of point of sickling as a cellular biomarker of dehydration before fluid resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event before fluid resuscitation therapy, approximately 2 hoursCellular dehydration marker, the elongation index will be measured by ektacytometry. It will be measured at 1 timepoint in 10 participants.
Measurement of point of sickling as a cellular biomarker of dehydration after fluid resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event after fluid resuscitation therapy, approximately 2 hoursCellular dehydration marker, the elongation index will be measured by ektacytometry. It will be measured at 1 timepoint in 10 participants.
Measurement of urine osmolality as laboratory biomarkers of dehydration before fluid resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event before fluid resuscitation therapy, approximately 2 hoursUrine osmolality values \<450 milliosmol/kg is considered abnormal in adults without fluid restrictions. It will be measured at 1 timepoint in 10 participants.
Measurement of urine osmolality as laboratory biomarkers of dehydration after fluid resuscitation therapy in SCD participants with VOC or VOEDuring a VOC or VOE event after fluid resuscitation therapy, approximately 2 hoursUrine osmolality values \<450 milliosmol/kg is considered abnormal in adults without fluid restrictions. It will be measured at 1 timepoint in 10 participants.

Countries

United States

Contacts

Primary ContactEnrico Novelli, MD
noveex@upmc.edu412-916-3416
Backup ContactManzoor Mohideen, PhD
mohideenm@upmc.edu412-802-8498

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026