Skip to content

Blood Biomarker Discovery by Raman Spectroscopy in Acute Aortic Dissection

Characterization of the Blood Signature as a Potential Tool for the Fast Diagnosis of of Acute Aortic Dissection

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05206032
Acronym
BBDRSAAD
Enrollment
500
Registered
2022-01-25
Start date
2021-12-01
Completion date
2022-12-31
Last updated
2022-01-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Aortic Dissection

Brief summary

This study intends to collect about 500 cases of blood samples from acute aortic dissection (AAD) and other acute chest pain diseases (eg, AMI, PE, or angina).The investigators tend to detect Raman metabolic profile of blood samples collected from AAD and other control groups using the Raman spectroscopy. The data collected will be analyzed and used to create a Raman database able to provide a classification model based on machine learning. The investigators then compared them with healthy participants to evaluate the diagnostic performance of different levels of Raman metabolic profile at discriminating AAD from other diagnoses and assess whether Raman metabolic profile is a potential novel biomarker for AAD under different circumstances.

Detailed description

Sample Collection: Blood (serum and plasma) collection from all the selected subjects at admission will be performed following the collection tube manufacturer's instructions. Then the collected samples will be stored at -80° C. Data Collection: For the Raman analysis, 5 μL of each sample will be casted on an aluminium foil in order to achieve the Surface Enhanced Raman Scattering (SERS). Raman and SERS spectra will be acquired using a WITec Alpha500 confocal micro-Raman spectroscopy system (WITec, Germany) with a 532 nm He-Ne laser (Research Electro-Optics, Inc., USA) as the excitation source, which offered a resolution of approximately 3 cm-1. The instrument will be calibrated before each analysis using the reference band of silicon at 520.7 cm-1. A 20× microscope objective (NA = 1.25, Zeiss, Germany) was used for spectral excitation and measurements. All spectral information were recorded by a back-illuminated deep-depletion charge coupled device camera (ardorTechnology, UK) working at -60°C with a 1.5 s acquisition time for a single spectrum with a spectral range of 300-4000 cm-1. The software package WITec Project spectral analysis (WITec GmbH, Germany) will be used for map design and the acquisition of spectra. Data Processing: All the acquired spectra will be fit with a nine-order polynomial baseline and normalized by unit vector using the dedicated WITec Project spectral analysis software. The statistical analysis to validate the method, will be performed using a multivariate analysis approach. Principal Component analysis (PCA) will be performed in order to reduce data dimensions and to evidence major trends. Mann-Whitney will be performed on PCs scores to verify the differences statistically relevant between the analysed groups. Correlation and partial correlation analysis will be performed using the Spearman's test, assuming as valid correlation only the coefficients with a p-value lower than 0.05. Subsequently, principal components analysis (PCA) combined with linear discriminant analysis (LDA), PCA combined with support vector machine (SVM), partial least squares-discriminant analysis (PLS-DA) and etc were tested for evaluation of diagnostic power. The statistical analysis will be performed using Origin2018 (OriginLab, USA) and MATLAB R2018b software (Mathworks. Inc., Natica, MA, USA).

Interventions

Blood (serum or plasma) will be collected, processed and analysed through Raman spectroscopy. Data acquired will be normalized and treated for the creation of the classification model.

Sponsors

First Affiliated Hospital Xi'an Jiaotong University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years

Inclusion criteria

Clinical diagnosis of AAD; Clinical diagnosis of AMI; Clinical diagnosis of PE; Clinical diagnosis of angina; Healthy participants; Provided written consent for the blood samples analysis; Age between 18 and 90 years.

Exclusion criteria

Transfusion history (packed red blood cells, whole blood, or platelets) 10 days before the blood sample was taken; Aortic trauma; Pseudo aneurysm; History of heart failure; Renal dysfunction; Severe pulmonary diseases; Active cancer; Checkup after surgery.

Design outcomes

Primary

MeasureTime frameDescription
Identification and characterization of a new AAD blood signature through Raman spectroscopyOne dayThe Raman analysis of blood samples collected from AAD patients and other control groups, will be used to characterize a AAD signature able to discriminate subjects from other chest pain individuals.
Correlation with the clinical characteristicsOne DayRaman data related to subjects with AAD will be correlated with the clinical data, validating in this way our methodology. The principal correlation will be carried out between the D-Dimer and B type urine natriuretic peptide(BNP) concentrations and Raman signature.
Portable Raman as point of careOne YearThe characterized and implemented classification model will be translated to a portable Raman equipped with a laser emitting at 532 nm and with a spectral resolution comparable with the one of the bench Raman. This station will be firstly tested with patients coming to the hospital and then applied continuously implementing the classification model with new Raman spectra and clinical data. In this way the investigators will highly implement the accuracy, sensitivity, precision and specificity of the model.

Countries

China

Contacts

Primary ContactZhanqin Zhang, PHD
zhanqin_zhang@xjtufh.edu.cn0086-13259983110

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026