Optimisation of Anticoagulation in Patients on Nocturnal Hemodialysis

Optimisation of Anticoagulation in Patients on Nocturnal Hemodialysis

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05204810
Enrollment
20
Registered
2022-01-24
Start date
2022-02-01
Completion date
2022-04-01
Last updated
2022-05-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coagulation, Hemodialysis

Keywords

Hemodialyzer, Fibre Clotting, Nocturnal dialysis

Brief summary

To avoid clotting during extracorporeal treatment, an anticoagulant is added to the circuit, resulting in an increased risk for bleeding complications. In addition, there is evidence that a substantial number of fibers can become blocked before this is reflected in routinely observed parameters, or in termination of the dialysis session. In standard hemodialysis of 4 hours, the anticoagulant is administered at the beginning of dialysis. For nocturnal hemodialysis, there is no hard evidence whether anticoagulation should be administered only at the dialysis start or with an extra dosing halfway the dialysis session. The aim of this randomized cross-over study is to objectively quantify the number of patent fibers after nocturnal dialysis in two different settings: anticoagulation only at the dialysis start, and anticoagulation divided over two time points, i.e. dialysis start and halfway dialysis.

Detailed description

This single centre, randomized cross-over study includes twenty stable chronic nocturnal hemodialysis patients with no coagulation disorder, active inflammation or chronic cumarin-derived medication. Patients are randomized over 2 study arms. Each patient is dialyzed over 480min (at midweek) with 2 different settings: anticoagulation only at the dialysis start, and anticoagulation divided over two time points, i.e. dialysis start and halfway dialysis. For each patient, the dialyzer, the dialysis mode (hemodialysis or hemodiafiltration) and the dialysis settings (blood flow, dialysate flow and substitution flow) are those as currently used by the patient during in-centre nocturnal dialysis. To determine antiXa, blood samples are taken from the inlet dialysis line at the dialysis start (i.e. 5min after administration of the anticoagulant) and at 1h, 4h and 8h after dialysis start. During the session with 2 anticoagulant administrations, an extra blood sample is taken before as well as after the second anticoagulant administration. Before the first test session, 1 blood sample is taken to determine antithrombin-III (AT-III). In order to quantify dialyzer performance in terms of number of patent fibers, dialyzers are scanned after dialysis, using a glod standard non-invasive micro-CT technique. Therefore, at the end of the dialysis session, a standard rinsing procedure of the hemodialyzer is performed using exact 300mL rinsing solution. Next, the hemodialyzer is dried using continuous positive pressure ventilation. Dialyzer fibre blocking is visualized in the dialyzer outlet potting using a 3D CT scanning technique on micrometer resolution. HECTOR is a High Energy CT scanner Optimized for Research, built by the Ghent University Centre for X-ray Tomography (UGCT) in collaboration with the UGCT spin-off company XRE (Gent, Belgium). In front of the X-ray source, the dialyzer is mounted vertically on a precision rotation stage, and radiographies were recorded over 360° with an angular interval of 0.15°. Scan conditions are optimized to maximize the signal-to-noise ratio based on the sample size and structure, and the scanner properties. The tube voltage is set at 80kV, at a power of 20 Watts, the maximal power that allowed imaging at a resolution of 25μm. A total of 2401 projections are recorded with 500ms exposure each, resulting in a total exposure time of 20 minutes. Acquired images at 0 (projection 1) and 360° (projection 2401) are compared to exclude movement of the hemodialyzer during the scanning process. Reconstruction of the raw projection data is performed with the Octopus Reconstruction software package, licensed by XRE23. The non-blocked fibers are counted in the central cross-section of the dialyzer outlet potting in a computer-based way using the Fiji image processing toolkit of ImageJ analysis software (ImageJ 1.51H, NIH, Bethesda, USA), an open-source platform for biological-image analysis. By comparing the number of non-blocked fibers in used versus non-used dialyzers, the percentage of fiber blocking can be calculated. By comparing the number of open fibers between the 2 test sessions (1 versus 2 anticoagulant administrations), the difference can objectively be scored for prolonged (nocturnal) dialysis.

Interventions

OTHERAnticoagulation strategy

For each session of this cross-over study, a different anticoagulation therapy is used: either 1 dose of anticoagulant or 2 doses of anticoagulant

OTHERBlood sampling

During the study sessions, blood sampling is performed from the arterial blood line at different time points (5min, 60min, 240min and at the dialysis end)

OTHERScanning of hemodialyzer with micro-computed tomography

After the study sessions, the used hemodialyzers are scanned using a gold standard micro computed tomography technique.

Sponsors

University Ghent
CollaboratorOTHER
University Hospital, Ghent
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 18 years or older * experienced stable dialysis sessions during the last 4 weeks * nocturnal in-centre hemodialysis * well functioning vascular access

Exclusion criteria

* known coagulation disorder * active inflammation * malignancy * no coumarin-derived medication

Design outcomes

Primary

MeasureTime frameDescription
Percentage of open fibers in hemodialyzer2 weeksBy scanning the hemodialyzers post dialysis using a reference micro-CT scanning technique, images are obtained from dialyzer cross-sections. Black dots can be counted as open fiber. By counting the number of open fibers and relating this number with the total numerb of fibers in sterile dialyzers, the percentage of open fibers can be quantified.

Secondary

MeasureTime frameDescription
Absolute value and change of the clotting parameter antiXa at different time points during dialysis2 weeksAntiXa (i.e. a measure to indicate anticoagulation by low molecular weight heparins) is followed in the patient at dialysis start and after 1, 4, and 8h.

Countries

Belgium

Outcome results