Analysis of Spatiotemporal Gait Parameters in Patients With Megaprosthesis.

Comparative Analysis of Spatiotemporal Gait Parameters in Patients With Distal Femoral Megaprosthesis and Healthy Subjects Using an Inertial Measurement Unit (IMU)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05202873
Acronym
MP-GP
Enrollment
79
Registered
2022-01-24
Start date
2018-02-08
Completion date
2024-11-01
Last updated
2024-12-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Distal Femoral Musculoskeletal Tumors, Megaprosthesis

Keywords

Gait Analysis, Case-control study, Megaprosthesis, Orthopedic oncology, Musculoskeletal tumour, Distal femur, Inertial Measurement Unit

Brief summary

The main objective of the study is to evaluate spatiotemporal parameters of gait in tumoral patients with megaprosthesis of the distal femur.

Detailed description

Patients with distal femoral prostheses treated at La Fe Hospital in Valencia were evaluated and compared with healthy controls. A radiographic study was conducted in cases using telemetric imaging to assess the percentage of remaining bone and the long length limb discrepancy following surgical intervention. Additionally, a gait analysis was performed using the BTS device to obtain objective gait parameters. The gait assessment was conducted with a non-invasive portable device, the BTS G-sensor inertial sensor (BTS Bioengineering, Garbagnate Milanese, Italy), which was placed at the S1 level to collect spatio-temporal gait data. The data were analyzed in relation to the values in healthy patients.

Interventions

DIAGNOSTIC_TESTGait analysis

Gait assessment will be performed using a non-invasive device. It is the BTS G-sensor inertial sensor (BTS Bioengineering, Garbagnate Milanese, Italy). The spatiotemporal variables of gait will be studied from the Walk+ protocol, in which the participant navigates a 7-meter hallway six times, completing three round trips with necessary turns at each end to change direction.

Sponsors

Cardenal Herrera University
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
16 Years to 99 Years
Healthy volunteers
Yes

Inclusion criteria

* Megaprosthesis of the distal femur * Tumor cause * Surgery at Hospital la Fe. * Traditional stem or biological ossteointegration system * Minimum postoperative follow-up period of 3 months

Exclusion criteria

* Neurological alterations prior to the intervention that affect the lower limbs or general movement. * Patient incapable of ambulation due to progression of his/her pathology * Patient at home with palliative treatment for advanced tumor disease * Any ipsilateral or contralateral prosthesis. * Infectious or traumatic cause

Design outcomes

Primary

MeasureTime frameDescription
Antero-posterior acceleration symmetry index3 monthsThis metric serves as a quantifiable measure of the symmetry exhibited in movements along the antero-posterior axis, thereby illustrating the equilibrium and coordination inherent in the body's kinetic activities.
Stance Phase3 monthsRefers to the portion of the gait cycle during which a foot is in contact with the ground. It begins with the initial contact (heel strike) and ends when the same foot leaves the ground (toe-off). The stance phase is a critical component of walking and running, contributing to balance, propulsion, and weight-bearing. Measured as a percentage of the total gait cycle, 60% of the cycle in typical walking.
Swing Phase3 monthsRefers to the portion of the gait cycle during which a foot is not in contact with the ground. It begins when the foot lifts off the ground (toe-off) and ends when the same foot makes contact again (heel strike). The swing phase allows the leg to advance forward and position itself for the next step. Measured as a percentage of the total gait cycle, 40% of the cycle in normal walking.
Gait Quality Index3 monthsThe stance-swing phase ratio
First Double support phase3 monthsRefers to the portion of the gait cycle during walking when both feet are in contact with the ground simultaneously. It occurs at the beginning of the stance phase for one leg, immediately after heel strike, and ends when the opposite foot lifts off (toe-off). This phase contributes to stability during gait. Measured as a percentage of the total gait cycle.
Single Support Phase3 monthsRefers to the portion of the gait cycle during which only one foot is in contact with the ground bearing the entire body weight while the other foot is in the swing phase. It is essential for maintaining balance and forward progression during walking. Measured as a percentage of the total gait cycle.
Propulsion Index3 monthsThis measures the subject's ability to propel the centre of mass forward during the single support stance phase.
Pelvic tilt range3 monthsRefers to the total angular movement of the pelvis in the sagittal plane during a specific activity, such as walking. It represents the difference between the maximum anterior tilt (forward rotation) and maximum posterior tilt (backward rotation) of the pelvis within a given cycle. Measured in degrees (°) to quantify the extent of pelvic rotation.
Pelvic obliquity range3 monthsRefers to the total angular movement of the pelvis in the coronal (frontal) plane during activities such as walking. It describes the difference between the maximum upward tilt (hip hike) and maximum downward tilt (hip drop) of one side of the pelvis relative to the opposite side. Measured in degrees (°) to quantify the range of motion.
Pelvic rotation range3 monthsRefers to the total angular movement of the pelvis in the transverse (horizontal) plane during activities such as walking. It represents the difference between the maximum forward rotation and maximum backward rotation of the pelvis around a vertical axis within a given cycle. Measured in degrees (°) to quantify the range of rotational motion.
Pelvic symmetry tilt index3 monthsIs a quantitative measure that evaluates the symmetry of pelvic tilt during movement. It assesses the degree of deviation in pelvic tilt between the left and right sides in the sagittal plane, providing insight into potential imbalances or asymmetries. Expressed as a percentage (%) to indicate the level of symmetry.
Pelvic symmetry obliquity index3 monthsIs a quantitative measure used to evaluate the symmetry of pelvic obliquity during movement. It quantifies the degree of deviation in upward or downward tilt of the pelvis on one side compared to the other in the coronal (frontal) plane, helping to identify potential imbalances or asymmetries. Expressed as a percentage (%) to represent the level of symmetry.
Pelvic symmetry rotation index3 monthsIs a quantitative measure used to assess the symmetry of pelvic rotation during movement, particularly in the transverse (horizontal) plane. It calculates the difference in rotational movement between the left and right sides of the pelvis, helping to identify any imbalances or asymmetries in pelvic motion during activities like walking.Expressed as a percentage (%) to indicate the level of symmetry.

Secondary

MeasureTime frameDescription
Bone remmant (%)3 monthsBone remment respect a healthy femur in percentage (%)
Long discrepancy (mm)3 monthsLong discrepancy in milimeters (mm) between healthy and tumoral leg. Positive discrepancy (tumoral leg longer) or negative discrepancy (tumoral leg shorter).