Skip to content

Optina Eye to Heart Connection

Use of a Deep Phenotyping Platform to Develop a Novel Retinal Imaging Test for Coronary Artery Disease: A Prospective Cross-Sectional Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05199428
Enrollment
308
Registered
2022-01-20
Start date
2022-06-15
Completion date
2024-03-22
Last updated
2024-05-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

This is a prospective cross-sectional, single-center retinal imaging study expecting to enroll approximately 400 male and female subjects ≥ 18 years of age. Subjects having undergone clinically-indicated coronary angiography or coronary computed tomography angiography (CCTA) within one month of consent at the Montreal Heart Institute (MHI) will be screened for inclusion in the study.

Detailed description

This is a prospective cross-sectional, single-center retinal imaging study expecting to enroll aproximately 400 (280 CAD and 120 control) male and female subjects ≥ 18 years of age. Subjects having undergone clinically-indicated invasive coronary angiography or coronary computed tomography angiography (CCTA) within one month of signed consent will be screened for inclusion in the study. Subjects will be recruited at the Montreal Heart Institute (MHI). During the screening visit, the investigator will review inclusion/exclusion criteria and the following information will be collected: demographic data including age and sex, relevant medical history including risk factors (hypertension, diabetes, dyslipidemia, smoking and obesity), history of CAD, concomitant cardiovascular medications and laboratory tests (lipid profile, fasting glucose) Subjects who provide written informed consent will undergo cognitive evaluation and an ophthalmic examination to identify any ocular exclusion criteria. All eligible subjects will then undergo hyperspectral retinal imaging using a Metabolic Hyperspectral Retinal Camera (MHRC) Safety will be assessed through reporting of serious adverse events (SAEs) related to retinal imaging procedures.

Interventions

None listed

Sponsors

Montreal Heart Institute
CollaboratorOTHER
Optina Diagnostics Inc.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Ability and willingness to give written informed consent * Age 18 years or older at the time of informed consent * Stable (non-emergent) typical or atypical symptoms suspicious for CAD (e.g., chest pain, chest tightness, chest burning, shoulder pain, palpitations, jaw pain, or non-chest pain symptoms such as dyspnea or worsening effort tolerance. * Patients having undergone clinically-indicated invasive coronary angiography or coronary computed tomography angiography within one month before consent signature

Exclusion criteria

1. At Screening Visit 1: 1. Asymptomatic subjects 2. Previous coronary revascularization (e.g., coronary artery bypass graft surgery, stenting) 3. Subjects being evaluated for other cardiac diseases (e.g., valvular disease, cardiomyopathy) 4. Pregnant or breastfeeding women 2. At Study Visit 2 or Ocular

Design outcomes

Primary

MeasureTime frameDescription
Sensitivity and specificity of a pre-specified classification model based on retinal imaging parameters1.5 yearSensitivity and specificity of a pre-specified classification model based on retinal imaging parameters to discriminate between control subjects and subjects with CAD (defined as stenosis in at least one epicardial vessel of 50% or greater) as assessed by coronary angiography.

Secondary

MeasureTime frameDescription
Correlation between retinal imaging parameters and the number of vessels with a stenosis of 50% or greater as assessed by coronary angiography.1.5 year
Correlation between retinal imaging parameters and the maximal severity of coronary artery stenosis as assessed by coronary angiography.1.5 year
Sensitivity and specificity of new classification models based on retinal imaging parameters1.5 yearSensitivity and specificity of new classification models based on retinal imaging parameters to discriminate between control subjects and subjects with CAD (defined as stenosis in at least one epicardial vessel of 50% or greater) as assessed by coronary angiography.
Correlation between retinal imaging parameters and cognitive scores on the Montreal Cognitive Assessment (MoCA) and executive tasks1.5 year
Sensitivity and specificity, among CAD subjects, of a pre-specified classification model, as well as new classification models1.5 yearSensitivity and specificity, among CAD subjects, of a pre-specified classification model, as well as of new classification models, based on retinal imaging parameters to discriminate between subjects with less severe CAD (less vessels with a stenosis of 50% or greater) and subjects with more severe CAD (more vessels with a stenosis of 50% or greater) as assessed by coronary angiography.

Countries

Canada

Outcome results

None listed