Skip to content

The Reliability of Myotonometer in Evaluating the Muscle Tone and Biomechanical Properties of the Forearm Muscles

The Reliability of Myotonometer in Evaluating the Muscle Tone and Biomechanical Properties of the Forearm Muscles: Investigation of the Effect of Grip Strength on Mechanical Features

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05183659
Enrollment
56
Registered
2022-01-10
Start date
2021-11-27
Completion date
2022-01-05
Last updated
2022-01-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Muscular Tone, Viscoelasticity

Keywords

elasticity, hardness, forearm muscles

Brief summary

The primary aim of this study was to evaluate the intra-rater and inter-rater reliability of MyotonPRO in measuring muscle tone and mechanical properties of the wrist extensor and flexor muscles in healthy young adults. The secondary aim is to examine whether grip strength has any effect on muscle tone and biomechanical properties.

Interventions

None listed

Sponsors

Bitlis Eren University
CollaboratorOTHER
Dokuz Eylul University
CollaboratorOTHER
İlke KARA, PT
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to 35 Years
Healthy volunteers
Yes

Inclusion criteria

* Age≥18 years * Body mass index \< 30 kg/meter square * Having no upper extremity injuries * Willing and able to provide the written informed consent for the study

Exclusion criteria

* Use of medication that will affect muscle tone * History of lateral or medial epicondylitis, trauma (elbow, hand or wrist), cervical radiculopathy, peripheral neuropathy or nerve injury (axillary, median, ulnar, radial, musculocutaneous), systemical diseases, muscle disorders (e.g. genetic diseases, neuromuscular disorders)

Design outcomes

Primary

MeasureTime frameDescription
Muscle tone (Hz)Day 1The muscle tone which is a biomechanical property of the forearm muscles will be evaluated with a portable hand-held myotonometer. This myotonometer (MyotonPRO - Tallinn, Estonia) is non-invasive and provides a quantitative assessment of a muscle's biomechanical properties. The MyotonPRO applies a short-intensity mechanical impulse on the skin overlying the muscle or facia. The tissue's response then generates a signal that is recorded, and an internal software program produces an acceleration graph. To determine the feasibility of the MyotonPRO for assessing the muscle tone of forearm muscles measurements will be performed and recorded.
Stiffness (N/m)Day 1The stiffness which is a biomechanical property of the forearm muscles will be evaluated with a portable hand-held myotonometer. This myotonometer (MyotonPRO - Tallinn, Estonia) is non-invasive and provides a quantitative assessment of a muscle's biomechanical properties. The MyotonPRO applies a short-intensity mechanical impulse on the skin overlying the muscle or facia. The tissue's response then generates a signal that is recorded, and an internal software program produces an acceleration graph. To determine the feasibility of the MyotonPRO for assessing the stiffness of forearm muscles measurements will be performed and recorded.
Elasticity (Logarithmic decrement)Day 1The elasticity which is a viscoelastic property of the forearm muscles will be evaluated with a portable hand-held myotonometer. This myotonometer (MyotonPRO - Tallinn, Estonia) is non-invasive and provides a quantitative assessment of a muscle's viscoelastic properties. The MyotonPRO applies a short-intensity mechanical impulse on the skin overlying the muscle or facia. The tissue's response then generates a signal that is recorded, and an internal software program produces an acceleration graph. To determine the feasibility of the MyotonPRO for assessing the stiffness of forearm muscles measurements will be performed and recorded.

Secondary

MeasureTime frameDescription
Grip StrengthDay 1Handgrip strength will be measured with the JAMAR Hydraulic Hand Dynamometer. Participants will be asked to sit down with knees and hip flexed to 90⁰, forearm in a neutral position, wrist in 0-30⁰ extension, and 0-5⁰ ulnar deviation while on a chair with backrest. During the measurement, the examiner will instruct them to squeeze the handles of the dynamometer as strongly as possible and then let them loose completely, with a loud motivating command. This will be repeated 3 times with 1-minute rest breaks and the average value will be calculated. During the measurements, the Jamar dynamometer will be grasped from the lower and upper parts by the examiner.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026