Skip to content

The HEALiX: Comparing the Efficacy of the HEALiX Device With Wrist Restraints in a Critical Care Setting

The HEALiX Trial: Comparing the Efficacy of the HEALiX Device With Wrist Restraints in a Critical Care Setting

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05180552
Enrollment
0
Registered
2022-01-06
Start date
2028-08-10
Completion date
2030-09-10
Last updated
2024-12-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Device Dislodgement, Device Ineffective, Device Intolerance, Safety Issues

Keywords

unplanned extubation, restraints, device removal, critical care unit, patient safety, wrist restraints, sedation, standard of care

Brief summary

The treatment plan for patients requiring mechanical ventilator support is to provide the minimal amount of analgesics and sedatives necessary for the patient to tolerate the ventilator as lower amounts of these drugs has been shown to improve patient outcomes. Patients in this critical state experience confusion, restlessness, and agitation, which sometimes leads to an unplanned removal of a patient's line or medical device. The current standard of care for limiting the movement of mechanically ventilated patients' in the critical care units in hospitals is the use of physical wrist restraints. Researchers demonstrated that wrist restraints are ineffective in preventing the removal of invasive and adjunct devices and have many negative physical, psychological, physiological, and emotional consequences for the patient and their family. In this proposed research, we will use the innovative medical device called the HEALiX, a newly developed device worn on the arms of mechanically ventilated patients that allows freedom of movement and protects from removing adjunct mechanical ventilation devices and invasive monitoring equipment. This randomized controlled trial will investigate the HEALiX device's effectiveness in preventing the removal of invasive monitoring devices (such as endotracheal tubes, central lines, feeding tubes, etc.) compared with the current standard of care, wrist restraints.

Detailed description

This randomized controlled trial's primary purpose is to determine the efficacy of the HEALiX compared with wrist restraints in the adult, intubated patient in the critical care and intermediate care setting. The study's secondary purpose is to understand the acceptability of the HEALiX from healthcare professionals' perspective providing care at the bedside. By recruiting participants for use in the HEALiX RCT study and using the HEALiX with patients during care, the PI will gather information regarding the comparative effectiveness of the HEALiX in a population of critical care patients. This RCT trial will use a quantitative, comparative approach using an experimental and control study group design to measure and compare the outcomes after the subjects are placed in either the HEALiX or wrist restraints. The setting for the HEALiX Pilot Study will be Penn State Hershey Medical Center in Hershey Pennsylvania. The specific location for the trial will be in several of the academic medical center's critical care units, including Heart and Vascular ICU (HVICU), Surgical Anesthesia ICU (SICU), Neurosurgical Intensive Care Unit (NSICU), and Medical Intensive Care Unit (MICU). Key nursing unit leaders and leaders from other service lines whose clinical input was essential to contribute to this RCT trial's success gave permission to conduct this study.

Interventions

DEVICEHEALiX is an alternative restraint patient safety device

The HEALiX is a rigid, spiral, exoskeleton-like device made of lightweight stainless steel (Austenitic SAE 316 or equivalent) that comes in various sizes to fit different arm lengths circumference of the patient's bicep. After appropriate measuring and following the fit guide, the HEALiX is placed on the patient's arm so that the hand rests on a soft, padded hand cradle. The trajectory of the end hand cradle is at a 30-degree upward angle to prevent peripheral dependent edema. This hand cradle is surrounded by foam to provide increased support for the patient and also to protect the medical team from any injury. A wrist bracelet (wrist assist) goes around the patient's wrist and prevents the patient from removing the device. The spiral exoskeleton holds the arm in a neutral position with contact points with the patient's skin at the upper deltoid region only.

DEVICEsoft wrist restraints

Soft wrist restraints are padded cloth restraints that are worn by patients on wrist and secured to bed frame.

Sponsors

Milton S. Hershey Medical Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Intervention model description

This randomized control trial will use a quantitative, comparative approach using an experimental and control study group design to measure and compare the outcomes after the subjects are placed in either the HEALiX or wrist restraints.

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

1. Mechanically ventilated (with or without tracheostomy) 2. Receiving analgesic-sedating medications 3. Wearing soft wrist restraints 4. Glasgow Coma Scale score \> 8 5. Participants must be between ages 18-89 years old 6. English-speaking 7. English speaking legalized authorized representative (LAR) 8. Participants must be admitted under one of the following physician groups: Trauma services or critical care physician group.

Exclusion criteria

1. Children (under age 18) 2. Pregnant women 3. Cognitively impaired adults (must be able to follow commands) 4. Prisoners 5. Combative patients

Design outcomes

Primary

MeasureTime frameDescription
Unplanned removal of devicesEnd of intubation (average 7 days)Frequency of unplanned removal of lines and self-extubation

Secondary

MeasureTime frameDescription
Days on the ventilator that each patient group remainsEnd of intubation (average 7 days)Days on the ventilator
Number of days in the ICU that each patient group remainsEnd of ICU stay when patient is transferred to lower level of care (average 10 days)Days in ICU
Ease of device useEnd of intubation (average 7 days)Staff perception of ease of HEALiX sizing, application and removal based on Likert scale where 0 is prohibitively hard to use and 5 is extraordinarily easy to use
Propofol Dosing1 DayTotal Propofol dosing in mg/kg
Midazolam Dosing1 DayTotal Midazolam dosing in mg/kg
Fentanyl Dosing1 DayTotal Fentanyl dosing in mcg/kg

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026