Skip to content

Ultrasonographic Diameter of Optic Nerve Sheath in Fluid Assessment in Severe Preeclamptic Patients

Reliability of Utrasonographic Diameter of Optic Nerve Sheath in Assessment of Fluid Status in Severe Preeclamptic Patients

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05176652
Enrollment
100
Registered
2022-01-04
Start date
2021-12-06
Completion date
2022-12-06
Last updated
2022-01-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Severe Pre-eclampsia

Brief summary

Changes in the optic nerve sheath diameter detected by ultrasound are considered an important manifestation of increased intracranial pressure . The normal optic nerve sheath diameter measures up to 5.0 mm and an average optic nerve sheath diameter more than 5 mm is considered abnormal and elevated intracranial pressure should be suspected.Cerebral edema have been demonstrated in 71% to 100% of magnetic resonance imaging in preeclamptic patients and an increase in optic nerve sheath diameter has been described in preeclamptic females compared to healthy pregnant females Therefore, Increased optic nerve sheath diameter can indirectly reflect the state of intracranial edema that could be a part of generalized edema of preeclampsia and it could be a possible marker of generalized tissue edema and fluid overload in these patients.

Interventions

RADIATIONultrasound

ultrasonographic assessment of optic nerve sheath diameter

Sponsors

Sohag University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 40 Years
Healthy volunteers
No

Inclusion criteria

* Systolic blood pressure of 160mm Hg or higher, or diastolic blood pressure of 110mm Hg or higher on 2 occasions at least 6 hours apart on bed rest. * Proteinuria ≥5g in a 24 hour urine specimen or ≥3+ on 2 random urine samples collected at least 4 hours apart. * patient acceptance * Accepted mental state of the patients

Exclusion criteria

* patient refusal to participate in the study * chronic kidney disease * chronic pulmonary disease * chronic cardiac disease * chronic hypertension * previous ocular operation and diseases

Design outcomes

Primary

MeasureTime frameDescription
correlation between optic nerve sheath diameter and extravascular lung waterup to 24 hourscorrelation between ultrasound assessment of optic nerve sheath diameter and extravascular lung water

Countries

Egypt

Contacts

Primary ContactHossam Eldin Hassan ahmed, assisstant lecturer
hossamhassan01000393835@gmail.com01000393835

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026